Model List - Viking VCWC524-SG33A User Manual & Service Manual

Table of Contents

Advertisement

USER GUIDE
E3: Thermistor 3 open.
E4: Thermistor 4 open (Does not apply to this model).
E5: Thermistor 1 shorted.
E6: Thermistor 2 shorted.
E7: Thermistor 3 shorted.
E8: Thermistor 4 shorted (Does not apply to this
model).
E9: Door 2 (lower) open.
P1: Pump Circuit open (Does not apply to thismodel).
15: CLEAR ERROR LOG
To clear errors, press and hold
CLR is flashing.
16: THERMISTOR - 1 DIFFERENTIAL
This number should not be adjusted.
17. Does not apply to this model.
18. THIS NUMBER SHOULD NOT BE ADJUSTED
19. THIS NUMBER SHOULD NOT BE ADJUSTED
20. INDIVIDUAL COMPONENT TOGGLE
Display #
- Option #0 – Exit
- Option #1 – Relay 1
- Option #2 – Relay 2
- Option #3 – Relay 3
- Option #4 – Relay 4
- Option #5 – Relay 5
- Option #6 – Relay 6
- Option #7 – DC Output 1
- Option #8 – DC Output 2
- Option #9 – DC Output 3
- Option #10 – DC Output 4
- Option #11 – DC Output 5
- Option #12 – Serial output (Compressor)
SEE RELAY / OUTPUT CHART
21. MODEL NUMBER INDICATOR
Displays the two-digit model number of the specific
unit. See Model list table.
22. LIGHT ALL LED SEGMENTS
This will illuminate all the LEDs on the display to
ensure they work properly
23. ACTIVATE DEFROST /HARVEST
-Press and hold for 3 seconds to activate
24. FACTORY DEFAULTS
-Press and hold for 3 seconds to restore all values to
factory defaults
25.
MAIN SOFTWARE
26. Does not apply to this model
Control Operation-Service
(5 seconds) when
Relay / Output
27. FACTORY TEST MODEL
0 = Off, 1 = On
28. COMPRESSOR RPM
29. FREEZE TIME ADJUST (MODEL 54 ONLY)
30. HARVEST TIME ADJUST (MODEL 54 ONLY)
31. LOW TEMP ALARM LIMIT (MODEL 55 ONLY)
32. HIGH TEMP ALARM LIMIT (MODEL 55 ONLY)

MODEL LIST

Model #
7
UHBV515-
9
UHBV518-
9
UHBV524-
11
U-CLR1215- ALL CLEAR ICE MODELS 2020 AND NEWER
15
UHFZ124/UOFZ1224
23
UHRE515-
25
UHRE518 /UHRE524-
37
UHWC515-
38
UHWC518 /UHWC524-
43
UHBD524-
48
UHWD524-
50
UHRF124-
52
UHRI124-
53
NUGGET 1 CLASS UHNP115/UHNB115 (134A)
54
UACP115-SS01A (CLEAR ICE ADA)
57
NUGGET 3 CLASS UHNP315/UHNB315
57
NUGGET 1 CLASS (R600)
57
UANP115- ADA NUGGET (R600)
79
UHCP115-**81A BRIGHT SHIELD CLEAR ICE MODELS
80
UHNP115-**81A BRIGHT SHIELD 3 CLASS NUGGET
PROGRAMMING THE UNIT TO CORRECT
MODEL NUMBER
1.
Disconnect the unit from power source.
2.
Push and hold the U-Line button.
3.
While still holding the U-Line button, plug the unit into
the appropriate power source.
4.
When the flashing digits appear (3-5 seconds), use the
up and down arrow buttons to select the appropriate
model number from the chart below.
5.
Press the light bulb button once.
6.
The display will blink, and then will appear as the
programmed display.
42