Table 12: Axial piston unit malfunction table
Malfunction
Excessively high temperature of
hydraulic fluid and housing
Bosch Rexroth AG, RE 92512-01-B/2023-03-27
Possible cause
Excessively high inlet temperature at the
axial piston unit
Wrong setting and/or malfunction of the
pressure relief and pressure control valves
(e.g. high-pressure relief valve, pressure
controller, pressure reducing valve)
Axial piston unit worn
Remedy
Machine/system manufacturer: Inspect system,
e.g. malfunction in the cooler, insufficient
hydraulic fluid in the reservoir
Optimize the adjustment of the pressure
limitation and pressure control valves of the
axial piston unit and the pressure safeguarding
in the hydraulic system
Contact Bosch Rexroth Service
Contact machine/system manufacturer
Replace axial piston unit;
contact Bosch Rexroth Service