Advertisement

Quick Links

INSTALLATION AND MAINTENANCE MANUAL
 
TRANSLATION OF THE
ORIGINAL DOCUMENT
HM0000148929ND15
 
For additional copies visit: 
www.frost‐trol.com
SOLID LINES
Versión: -1
D003996
 

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HM0000148929ND15 and is the answer not in the manual?

Questions and answers

Summary of Contents for frost-trol HM0000148929ND15

  • Page 1 INSTALLATION AND MAINTENANCE MANUAL HM0000148929ND15 SOLID LINES       Versión: -1 For additional copies visit:  TRANSLATION OF THE ORIGINAL DOCUMENT D003996 www.frost‐trol.com...
  • Page 2: Table Of Contents

    SPARE PARTS REQUEST ..............23     FAULTS AND REPAIRS ..............24     6.1. MALFUNCTIONS ................24     6.1.1. THE UNIT DOESN’T START UP OR IT STOPS: ........24     TRANSLATION OF THE HM0000148929ND15 For additional copies visit:  ORIGINAL DOCUMENT www.frost‐trol.com D003996 Versión: -1...
  • Page 3 6.2. FINAL SHUTDOWN ................. 26     6.3. DISMANTLING THE CABINET ............26     6.4. DECLARTION OF ROHS CONFORMITY ..........27     GUARANTEE ................. 27     TRANSLATION OF THE HM0000148929ND15 For additional copies visit:  ORIGINAL DOCUMENT www.frost‐trol.com D003996 Versión: -1...
  • Page 5: Safety Advice

    Do not use any electrical appliances inside the storage compartments for the food frozen by the equipment, unless recommended by the manufacturer. Do no damage the refrigerating circuit. TRANSLATION OF THE HM0000148929ND15 For additional copies visit:  ORIGINAL DOCUMENT www.frost‐trol.com D003996 Versión: -1...
  • Page 6 Ensure that the power supply voltage meets the details on the rating plate of the cabinet. The cabinet must be properly connected to the earthing system. TRANSLATION OF THE HM0000148929ND15 For additional copies visit:  ORIGINAL DOCUMENT www.frost‐trol.com D003996...
  • Page 7 Gloves should be worn during product loading operations. Any other use not explicitly mentioned in this handbook must be considered as hazardous. The manufacturer disclaims all liability for damage resulting from improper, incorrect or unreasonable use. TRANSLATION OF THE HM0000148929ND15 For additional copies visit:  ORIGINAL DOCUMENT www.frost‐trol.com D003996...
  • Page 8: General Information

    1. GENERAL INFORMATION Welcome to the new series of remote refrigerated display cabinet modules from Frost-Trol for the sale of perishable food products. We are delighted by your decision to choose us. This assembly and maintenance manual has been especially designed with a view...
  • Page 9: Description Of Refrigerated Display Cabinet

    The cabinet referred to in this manual is a vertical self-service multideck refrigeration display cabinet that has been designed specifically for the sale of refrigerated products. The cabinet has a wide range of optional accessories. If you need details about its assemblage, please contact with Frost-trol, S.A. 1.2. GENERAL CHARACTERISTICS HM0000148929ND15...
  • Page 10: Technical Information And Access To Eprel

    1.4. SHOP CONDITIONS Frost-trol refrigerated display cabinets are designed to operate in air-conditioned areas that maintain an air temperature of 25º C and a maximum relative humidity of 60 % (climate class 3, in accordance with ISO EN 23953-2). The performance of...
  • Page 11: Fixation Of The Recommended Temperature In Each Compartiment

    Frost-Trol Commercial Department or our official representative for your country. This refrigerated display cabinet has been thoroughly inspected to ensure the highest level of quality. Any order for components should be made to Frost-Trol or TRANSLATION OF THE HM0000148929ND15 For additional copies visit: ...
  • Page 12: Damage Sustained In Transit

    Technical Department. If you need to get in contact with Frost-Trol with regard to a specific element, please make sure that you are able to quote the model and serial number. This information can be found on the nameplate, which is located inside the refrigerated display cabinet.
  • Page 13: Intallation Of Refrigerated Display Cabinet

    It’s mandatory to leave 8cm between the cabinet rear wall and the supermarket wall to ensure the airflow. Keep the condensing unit openings free from obstructions. 2.2. UPACKING Unpacking is reserved for skilled personnel. TRANSLATION OF THE HM0000148929ND15 For additional copies visit:  ORIGINAL DOCUMENT www.frost‐trol.com D003996 Versión: -1 -13-...
  • Page 14: Levelling

    Protect the drip piping system against freezing as needed. ‐ Do not install drip piping in contact with not insulated suction lines. ‐ Avoid installing excessive pipe length. ‐ TRANSLATION OF THE HM0000148929ND15 For additional copies visit:  ORIGINAL DOCUMENT www.frost‐trol.com D003996 Versión: -1 -14-...
  • Page 15: Refrigerating System Connection

    20±0,5 bar. Check this value before depressurising. If this is not the case then do not actuate the cabinet and contact the Frost-Trol technical department within 72 hours. The refrigerated cabinet must be dehydrated in avacuum and at the unit's normal operating pressure.
  • Page 16: Electrical Connection

    This switch has to be directly connected to supply terminals and has to be able to provide full disconnection in all poles under overvoltage Category III conditions. TRANSLATION OF THE HM0000148929ND15 For additional copies visit:  ORIGINAL DOCUMENT www.frost‐trol.com D003996 Versión: -1...
  • Page 17: Cleaning

    Before the first use, it’s mandatory to clean the unit thoroughly, both inside and out, with non-abrasive detergents and rinse well with water. Dry the inside with a cloth so that no water remains inside the unit (see Chapter 4). TRANSLATION OF THE HM0000148929ND15 For additional copies visit:  ORIGINAL DOCUMENT www.frost‐trol.com D003996 Versión: -1...
  • Page 18: Operation

    Load the products into the cabinet in such a way that you can ensure ‐ good stock rotation; Empty spaces should be left between products to ensure perfect air ‐ circulation around them. TRANSLATION OF THE HM0000148929ND15 For additional copies visit:  ORIGINAL DOCUMENT www.frost‐trol.com D003996 Versión: -1 -18-...
  • Page 19 An improper preservation temperature may turn the foodstuffs into something harmful for the consumer’s health and facilitate germ and toxin spreading. The preservation period will depend on the type of product and the storage temperature. TRANSLATION OF THE HM0000148929ND15 For additional copies visit:  ORIGINAL DOCUMENT www.frost‐trol.com D003996 Versión: -1...
  • Page 20: Maintenance And Cleaning

    4.1. GENERIC CLEANING ROUTINE Clean the cabinet with non-abrasive detergents. Cleaning products have to be suitable for use with foodstuffs. Ensure a good rinse to remove all detergent TRANSLATION OF THE HM0000148929ND15 For additional copies visit:  ORIGINAL DOCUMENT www.frost‐trol.com D003996 Versión: -1...
  • Page 21: Internal Cleaning Procedure

    DOORS MAINTENANCE The cleaning of the cabinet door's must be done following these instructions: Treated surfaces may be cleaned with an ammonia–free household glass cleaner and a sponge, tissue or paper towel. TRANSLATION OF THE HM0000148929ND15 For additional copies visit:  ORIGINAL DOCUMENT www.frost‐trol.com D003996 Versión: -1...
  • Page 22: Replacing Lamps

    Lamps are fixed to cabinet with magnetic supports. To replace them, it is simply necessary to pull them down (1) and disconnect the cable from the power in cable (2) and replace them with tubes of the same characteristics. TRANSLATION OF THE HM0000148929ND15 For additional copies visit:  ORIGINAL DOCUMENT www.frost‐trol.com D003996 Versión: -1...
  • Page 23: Spare Parts Request

    *The series number is indicated inside the refrigerated cabinet, on the characteristics plate. ** Taking the customer’s standing position as a reference. *** You may request to Frost-trol the spare parts cross-section. Tabla 5. Name plate According to point 2 in the Annex II from the Regulation 2019/2024 (Ecodesign),...
  • Page 24: Faults And Repairs

    In case of malfunctioning, the following information is completely necessary to find the reasons of the trouble and suggest the solution for it: TRANSLATION OF THE HM0000148929ND15 For additional copies visit:  ORIGINAL DOCUMENT www.frost‐trol.com D003996 Versión: -1...
  • Page 25 Expansion valve superheat (measured): State of liquid sight glass (full, partially full, empty): Defrost heaters amps (when it’s mounted): Other details, or photos, that could help will redound to find a quicker solution. TRANSLATION OF THE HM0000148929ND15 For additional copies visit:  ORIGINAL DOCUMENT www.frost‐trol.com D003996 Versión: -1...
  • Page 26: Final Shutdown

    INSTALLATION AND MAINTENANCE MANUAL  6.2. FINAL SHUTDOWN We, Frost-trol SA, declare this product is covered by Directive 2002/96/CE (Waste Electrical and Electronic Equipment) designed to halt the increase of this type of waste and promote recycling as well as decreasing disposal. The symbol of the crossed-out waste bin that appears on the Nameplate declares: that the product was put in circulation after 13th ‐...
  • Page 27: Declartion Of Rohs Conformity

    6.4. DECLARTION OF ROHS CONFORMITY We, Frost-trol, S.A. declare under our sole responsibility that the refrigerated cabinet complies with the provisions of Directive 2002/96/EEC (RoHS). In all the homogeneous materials used for its production, any content of lead, mercury, hexavalent chrome, polybrominated biphenyl (PBB), and polybrominated diphenil ether (PBDE) does not exceed, in weight 0.1%;...
  • Page 28 Frost-trol, S.A. Technical Department Avda. del Castell Vell, 176 12004 Castellón (Spain). Phone.: 0034 964 34 27 40 Fax: 0034 964 21 51 48 e-mail: frost-trol@frost-trol.com www.frost-trol.com...

Table of Contents