Aquatis 1. Important recommendations 1.1. Important safety instructions Before using this device, please read this manual carefully and keep it for future reference. Use this device only for its intended purpose, as described in this manual. This device must not be used by children under 8 years of age or by persons with reduced...
Respect the lifetime of consumables and replace them according to the instructions. Do not attempt to repair, disassemble or modify the unit yourself. These instructions are intended to help you install Aquatis. The visuals shown are not contractual. Be careful not to reverse the batteries.
Aquatis 2. Description 2.1. Technical data : filtration of sediments, chlorine tastes and odors with10µmactivated carbon. • : filtration of pesticides, herbicides, with10µmactivated carbon. • : filtration of bacteria and viruses with 0.1µmhollow-fiber membrane. • • Electronic board powered by 2 x 1.5V AA LR6 batteries (included).
Aquatis 2.2. How to use the device Device for drinking water only, to be connected to the mains water supply. Filter life depends on the quantity and quality of the water being treated, and on the length of time it is used for hygienic reasons.
Aquatis 3. Control panel operation 3.1. The control panel A control panel shows the state of wear of the filters and indicates when replacement is necessary. The panel consists of 3 LEDs A, B and C , which can be green, orange or red, and 3 buttons 1, 2 and 3.
Aquatis 4. Before installation Install the valve according to the dedicated instructions. 4.1. Checking accessories Aquatis 1 or 3-way valve 3 filter cartridges Bag of (optional) accessories optional extras 1 Under-sink wedge for thin Hoses. stainless steel models.* 2 Washer under tap*...
Page 9
Aquatis Dimensions: 36 x 27.5 x 9 cm. Allow for a wall dimension of 50 x 27.5 x 9 cm, corresponding to the space required for filter cartridge replacement. > Before installation...
Aquatis 5. Installation 5.1. Support preparation You can use the filter head support bracket to mark the fixing points. Use a spirit level to ensure correct positioning. Then drill to the Ø of the screws or plugs, depending on the mounting support. Then fit the 2 top screws.
Aquatis 5.3. Fixing the Aquatis Remove the cover and attach the unit to the bracket. 5.4. Hydraulic connection and valve installation Step 1: Cut off the water supply to your kitchen or, failing that, to your home. Step 2: Open the valve to relieve the pressure in the system.
Page 12
Pay attention to the direction of connection. Make sure to pass the pipe through hole Step 6: As with the inlet pipe, cut the Aquatis outlet pipe to size. Connect it to the OUT output of the device. Pass the hose through passage 2. The hose is connected using the automatic push connector.
Page 13
Ensure that the plastic connector is correctly fitted to the filtered water inlet on the tap. Remove the blue tab on the connector, then clip the Aquatis outlet hose onto the pure filtered water tap connector. Check for correct mechanical connection by pulling on the hose.
Place the cartridge to be inserted under the corresponding slot. To align the cartridge with Aquatis, position it between the two sides showing information. Once engaged, rotate the cartridge a quarter-turn to the right. The label must be visible from the front.
5.7. Place the batteries on the electronic card LR6-AA batteries must have the correct polarity. Once the batteries are installed, all three Aquatis LEDs should light up green. If they don't light up, check that the batteries have been inserted the right way round.
5.8. Commissioning Gradually open the system's general shut-off valve, then the Aquatis shut-off valve. Check for leaks during 48 hours by visual inspection. Open the tap used for the filtered water and let the water run for a few minutes through the small filtered water lever to rinse the cartridges.
Open the filter tap and let the filtered water run. While the water is running, turn off the water supply by turning the shut-off valve on the Aquatis tap a quarter-turn to the right. The valve blades must be perpendicular to the pipe. The water will continue to flow slightly from the filtration tap.
Page 18
Aquatis CAUTION: keep cartridges upright as they are still full of water. Replace the new cartridge by pushing it upwards and turning it to the right, with the seals previously coated with food-grade silicone grease. Once the cartridge is installed, press the button corresponding to the cartridge for 5 seconds, until the LED flashes green twice rapidly and the beeper sounds twice rapidly.
Aquatis Let the water run for several minutes to rinse the cartridge. A whitish or even cloudy appearance may appear. This is due to small air bubbles being expelled from the prefiltration and ultrafiltration cartridges. The water is perfectly drinkable and of excellent quality.
Page 20
Aalberts hydronic flow control Nederland France United Kingdom Fort Blauwkapel 1 77-79 Boulevard de Stalingrad Washway Lane / UK-WA10 6PB St 1358 AD Almere 69100 Villeurbanne Helens, Merseyside +31 (0)36 526 2300 info@aalberts-hfc.com +33 (0) 986 000 400 +44 17 447 447 44 fr.info@aalberts-hfc.com uk.info@aalberts-hfc.com aalberts-hfc.com...