BANDELIN SONOREX TECHNIK HA 40 Operating Manual

Planing head holder

Advertisement

Quick Links

Operating manual
T r a n s l a t i o n o f o p e r a t i n g m a n u a l
SONOREX TECHNIK
Planing head holder
Example 3 4 HA 40
Valid for:
HA 40
HA 110
HA 112
HA 210
22676-004 en/2024-01
Example 3 4 HA 110

Advertisement

Table of Contents
loading

Summary of Contents for BANDELIN SONOREX TECHNIK HA 40

  • Page 1 Operating manual T r a n s l a t i o n o f o p e r a t i n g m a n u a l SONOREX TECHNIK Planing head holder Example 3 4 HA 40 Valid for: Example 3 4 HA 110 HA 40...
  • Page 2 © 2024 1 2 GmbH & Co. KG, Heinrichstr. 3–4, 12207 Berlin, Germany Tel.: +49 30 76880-0, Fax: +49 30 7734699, info@bandelin.com Certified to ISO 9001 and ISO 13485 2 / 24 22676-004 en/2024-01...
  • Page 3: Table Of Contents

    Table of contents About this instruction manual ......................5 Safety ..............................6 Using the device ...........................6 Keep out of reach of children ......................6 Risk of electric shock ..........................7 Interference with wireless communication .................7 Safety stickers on the device ......................8 Not overloading the appliance ......................8 Construction and function ........................
  • Page 4 Disposal ..............................19 Information about the device ......................20 Technical specifications ........................20 Ambient conditions .......................... 21 CE conformity ............................. 21 Annex ..............................22 4 / 24 22676-004 en/2024-01...
  • Page 5: About This Instruction Manual

    • Should this instruction manual leave any questions unanswered, please contact your specialist dealer or BANDELIN. Notes on service can be found in chapter 6.3 Repairs. In the event that the translation cannot be understood, the German original version of BANDELIN must be followed.
  • Page 6: Safety

    Safety Safety Using the device The planing head holder makes it possible to hang planing heads or saw blades in a SONOREX TECHNIK RM device. This way, they can be cleaned quickly and thoroughly with ultrasound. What's more, the risk of injury is significantly reduced compared to manual cleaning.
  • Page 7: Risk Of Electric Shock

    Safety Risk of electric shock The device is an electrical device. Failure to follow safety rules can result in a life-threatening electric shock. • Never let the device become wet. Keep the surface and controls clean and dry. • Do not rinse the device or expose it to splash water. •...
  • Page 8: Safety Stickers On The Device

    Safety Safety stickers on the device • Observe all safety stickers on the device. • Keep the safety stickers in a readable state. Do not remove them. Replace them when they are no longer legible. Please contact our customer service for this. See chapter 6.3 Repairs.
  • Page 9: Construction And Function

    Construction and function Construction and function Construction 1 Guide rollers 2 Planing head with axle 3 Control 4 Undervoltage switch 5 Axial screw 6 Distance to the tank wall (no touching) 9 / 24 22676-004 en/2024-01...
  • Page 10: Control Panel

    Construction and function Control panel 1 Turning knob for adjusting the duration Undervoltage switch The device does not start automatically when first being put into service and after the mains voltage has suffered an outage. It must be released manually. To release, press the green button on the undervoltage switch.
  • Page 11: Preparing For Operation

    Preparing for operation Preparing for operation Installation site requirements The installation site of the device must meet the following conditions: • The installation surface must be horizontal, firm and dry. • The load-bearing capacity must be sufficient for the device together with a planing head. For weight, see chapter 8.1 Technical specifications.
  • Page 12: Installation And Connections

    Preparing for operation 1 Front frame (with control) 2 Rear frame 3 Hanger connector 4 Frame connectors 5 Holding axle 6 Screws, washers and nuts Installation and connections Remove transport aids (pallets, transport locks) completely. 4.3.1 Planing head holder HA 40 •...
  • Page 13: 4.3.2 Planing Head Holder Ha 110 To Ha 210

    Preparing for operation 4.3.2 Planing head holder HA 110 to HA 210 • Build the support: first, screw the "front frame" to the two "frame connectors" (see pictures). • Then screw on the "rear frame" (see pictures). • Temporarily dismantle any already installed hose connections on the SONOREX TECHNIK RM device (overflow and spray pipe).
  • Page 14 Preparing for operation 1 Front frame (with control) 2 Rear frame 3 Hanger connector 4 Frame connectors 14 / 24 22676-004 en/2024-01...
  • Page 15: Operation

    Operation Operation Putting into service The supplied O-rings are for fixing saw blades in place on the holding axle. These are not required if a planing head is to be cleaned. Requirements • The mains plug needs to be plugged into an earthed wall socket. Procedure Fill the ultrasonic device with cleaning agent.
  • Page 16: Switching The Rotational Movement On And Off

    Operation Switching the rotational movement on and off Requirements • The mains plug needs to be plugged into a wall socket with an earthed safety contact. Procedure 1. Turn the turning knob for the time switch to the desired duration or to the ∞ symbol for continuous operation. » The planing head holder is switched on. The motor for the rotational movement can be heard.
  • Page 17: Maintenance

    Maintenance Maintenance Servicing The device is maintenance-free. Cleaning and caring for the device The guide and drive rollers must be cleaned by wiping at regular intervals (about every 4 weeks). 17 / 24 22676-004 en/2024-01...
  • Page 18: Repairs

    Fill out the form and attach it so as to be clearly visible on the outside of the packaging. Acceptance will be refused without a completed form. Send the unit to the following address: BANDELIN electronic GmbH & Co. KG Heinrichstr. 3–4 12207 Berlin...
  • Page 19: Disposal

    Disposal Disposal WARNING Health hazard due to contaminated device - Decontaminate the device before disposal if it has come into contact with hazardous substances. - Also decontaminate accessories before disposal. Dispose of the device properly as electrical waste if it can no longer be used. Do not dispose of the device in the household waste.
  • Page 20: Information About The Device

    Information about the device Information about the device Technical specifications Electrical data, general Mains supply 230 V (± 10%) 50/60 Hz Mains cable Protection class Degree of protection IP 32 Type: HA 40 HA 110 HA 112 HA 210 Rotation speed: approx.
  • Page 21: Ambient Conditions

    Information about the device Ambient conditions Overvoltage category: Degree of contamination: Permissible ambient temperature: 5 … 40 °C Permissible relative humidity up to 31 °C: 80% (non-condensing) Permissible relative humidity up to 40 °C: 50% (non-condensing) Altitude < 2000 m above sea level For indoor operation only CE conformity The device meets the CE marking criteria of the European Union:...
  • Page 22: Annex

    Annex Annex Recommended preparations The choice of one of the following concentrates will depend on the cleaning task in question and the degree of soiling. TICKOPUR R 33 Universal cleaner For light soiling. Concentrate. With corrosion protection. Gentle cleaning. Mildly alkaline, pH 9.9 (1%). Also for light metals. Application: 5%, approx.
  • Page 23 23 / 24 22676-004 en/2024-01...
  • Page 24 1 2 GmbH & Co. KG Heinrichstrasse 3 – 4 12207 Berlin Germany Tel.: +49 30 76880-0 Fax: +49 30 7734699 info@bandelin.com www.bandelin.com...

Table of Contents