Flowmatic TZ-FLOWTRAP Manual

Flowmatic TZ-FLOWTRAP Manual

Trapmatic automatic trap primer

Advertisement

To ensure safe and enduring performance of this product, you must comply strictly with the instructions enclosed herein. Non-compliance with
instructions or improper handling of the product will void your warranty! This product is designed for use exclusively with types of fluids or
gasses as stated in its documentation. Usage of this product in conditions not specified in the product documentation or contrary to the
instructions hereby provided is considered IMPROPER. The manufacturer will not be held liable for any damages resulting from improper use of
the product.
-
Observe valid and generally accepted safety rules when planning, installing and using this product.
-
Take proper measures to prevent unintentional operation of the product or damage to it.
-
Do not attempt to disassemble this product or lines in the system while they are under pressure.
-
Always turn off the voltage supply before working on the system.
It is important that personnel use safe working practices and observe all regulations and legal requirements for safety when operating this
product. When handling, operating or carrying out maintenance on this product, personnel must employ safe engineering practices and observe
all local health & safety requirements & regulations. International users refer to regulations that prevail within the country of installation. Most
accidents which occur during the operation and maintenance of machinery are the result of failure to observe basic safety rules or precautions.
An accident can often be avoided by recognising a situation that is potentially dangerous. Improper operation or maintenance of this product
could be dangerous and result in an accident causing injury or death. The manufacturer cannot anticipate every possible circumstance which
may represent a potential hazard. The WARNINGS in this manual cover the most common potential hazards and are therefore not all-inclusive.
If the user employs an operating procedure, an item of equipment or a method of working which is not specifically recommended by the
manufacturer he must ensure that the product will not be damaged or made unsafe and that there is no risk to persons or property.
PLEASE NOTE:
Switch off the voltage supply before
installation or maintenance is carried out!
AUTOMATIC TRAP PRIMER
INDEX
Page 1
Page 2
Page 3
Page 4
Page 5
Page 6
Safety & Proper Usage
YOUR WARRANTY WILL BE INVALIDATED IF THE EQUIPMENT HAS NOT BEEN
INSTALLED OR MAINTAINED IN ACCORDANCE WITH THESE INSTRUCTIONS.
TRAPMATIC
General safety instructions
Installation instructions
Installation instructions
Installation instructions
Functions explained, General description
Installation/maintenance notes and specifications
Attention
Safety
installation or maintenance is carried out!
(Part 1 of 3)
(Part 2 of 3)
(Part 3 of 3)
Depressurise the system before

Advertisement

Table of Contents
loading

Summary of Contents for Flowmatic TZ-FLOWTRAP

  • Page 1 TRAPMATIC AUTOMATIC TRAP PRIMER INDEX Page 1 General safety instructions Page 2 Installation instructions (Part 1 of 3) Page 3 Installation instructions (Part 2 of 3) Page 4 Installation instructions (Part 3 of 3) Page 5 Functions explained, General description Page 6 Installation/maintenance notes and specifications Safety &...
  • Page 2: Important Notice

    INSTALLATION INSTRUCTIONS (Part 1 of 3) IMPORTANT NOTICE Unpack the unit and visually inspect for any transport damage incurred after leaving our factory Before installing this product make sure it complies with your request and that it suits your application! Screw Flat gasket Gasket B...
  • Page 3 INSTALLATION INSTRUCTIONS (Part 2 of 3) The D-Lux will start with its pre-set time setting of When the unit is installed correctly, and when it is 10 sec ON and 30 sec OFF. The display will start operational, you can change the pre-set values to counting down the ON time (10, 9, 8, etc.) anything ranging from 0.1 sec to 99 hrs.To change and the SEC led will be flashing.
  • Page 4 INSTALLATION INSTRUCTIONS (Part 3 of 3) If the desired OFF time is set, then simply don’t press any buttons and after a few seconds the display The unit is now fully programmed to your desired will start flashing illustrating that the new time is being saved. Once time settings and will work fully automatically.
  • Page 5: Returning To The Factory Settings

    Returning To The Factory Settings Factory settings of each timer: 10s ON time, 30s OFF time, function ‘A’. No matter how you change the settings you can always reset all settings to factory settings. To do so please follow these easy steps: Disconnect unit from the power supply.
  • Page 6: Maintenance

    ASSEMBLY OF COMPONENTS If the automatic trap priming valve is supplied as an individual unit, then the installer is to  provide a mini stop valve to control the flow.  assemble the vacuum breaker and fittings provided in the order as shown in the image below. Please take care to note the direction of flow as indicated on the valve.

Table of Contents