Advertisement

Quick Links

Fasep 2000 srl
Rev. 1.0
Balatron 103: User's Manual
June,10 2020
BALATRON 103
USER'S MANUAL
B103
www.fasep.it
For any information, please contact:
export@fasep.it
e-mail:
FASEP 2000 srl
Via Faentina 96
50032 Ronta (Fi) Italy
Tel. #39 055 8403126
Fax #39 055 2691906
i

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BALATRON 103 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Fasep BALATRON 103

  • Page 1 Fasep 2000 srl Rev. 1.0 Balatron 103: User’s Manual June,10 2020 BALATRON 103 USER’S MANUAL B103 www.fasep.it For any information, please contact: export@fasep.it e-mail: FASEP 2000 srl Via Faentina 96 50032 Ronta (Fi) Italy Tel. #39 055 8403126 Fax #39 055 2691906...
  • Page 2: Warning

    June,10 2020 WARNING .This document contains information which is the property of FASEP 2000 srl and all rights are reserved. This manual shall not be photocopied or reproduced in any way without the prior written consent of FASEP 2000 srl.
  • Page 3: Table Of Contents

    Fasep 2000 srl Rev. 1.0 Balatron 103: User’s Manual June,10 2020 TABLE OF CONTENTS WARNING ................... ii SYMBOLS AND CONVENTIONS .
  • Page 4: Presentation

    Fasep 2000 srl Rev. 1.0 Balatron 103: User’s Manual June,10 2020 PRESENTATION Intended Use This unit is designed to measure and correct static and dynamic unbalance of vehicle wheel, the dimension and weight of which are within the working range of the machine (see “Technical Data”appendix for reference) This unit is meant for a professional use.
  • Page 5: Installation

    Fasep 2000 srl Rev. 1.0 Balatron 103: User’s Manual June,10 2020 INSTALLATION Moving the unit In order to facilitate the transport it is supplied in packs equips you of pallets. To transport the machine on site, use suitable lifting or mobile industrial handling equipment.
  • Page 6: Use The Control Panel

    Fasep 2000 srl Rev. 1.0 Balatron 103: User’s Manual June,10 2020 USE THE CONTROL PANEL . 4: Panel Balatron 2000 Meaning of keys at the keyboard These instructions apply to Normal Operating Mode. Other function maybe activated by these keys in other operating modes (see Special Functions).
  • Page 7: Calibration

    Fasep 2000 srl Rev. 1.0 Balatron 103: User’s Manual June,10 2020 CALIBRATION How to calibrate the Wheel Balancer (USER)  NOTE the following symptoms indicate need for calibration: a) check calibration program fails. b) constant low or high weight readings.
  • Page 8: How To Check The Calibration Of Wheel Balancer

    Fasep 2000 srl Rev. 1.0 Balatron 103: User’s Manual June,10 2020 How to check the calibration of Wheel Balancer (USER) ATTENTION select mode CAL USR Press <+/-> to select CAL TEST . 11 Place a wheel on the flange. Insert the distance measure (IN) (Fig.13).
  • Page 9: Measurement And Correction Of Unbalance

    Fasep 2000 srl Rev. 1.0 Balatron 103: User’s Manual June,10 2020 MEASUREMENT AND CORRECTION OF UNBALANCE Placing the wheel rim on the wheel balancer 5.1.1 Select the cone or flange suitable for the wheel to be balanced. Specific mounting instructions are delivered with each flange.
  • Page 10 Fasep 2000 srl Rev. 1.0 Balatron 103: User’s Manual June,10 2020 5.2.2 DYNAMIC MODE / STATIC MODE/ ALU ( with motorbike extension) Press FUNC to select MOT ON. Install motorbike extension on the external measurement rod. Press MODE to select the operating mode.
  • Page 11: How To Apply The Weight Using Alu-Se Indicator

    Fasep 2000 srl Rev. 1.0 Balatron 103: User’s Manual June,10 2020 Input of Rim Dimensions 5.3.1 After setting wheel dimensions, execute the wheel launch using the appropriate wheel spinner.  NOTE: Acc El: impress greater speed. rEd UCE : reduce the speed.
  • Page 12: How To Use Split Weight Function

    Fasep 2000 srl Rev. 1.0 Balatron 103: User’s Manual June,10 2020 HOW TO USE SPLIT WEIGHT FUNCTION Measure the unbalance of the wheel. Once the measurement of unbalance is calculated, press <FUNC> to enter split function. Turn the wheel until POS 1 is displayed.
  • Page 13: Special Functions Menu

    Fasep 2000 srl Rev. 1.0 Balatron 103: User’s Manual June,10 2020 SPECIAL FUNCTIONS MENU Enter in the special functions menu Switch on the wheel balancer. Press <SET> before SOF X.XX will disappear. Calibration of wheel balancer CAL tSt Control of the calibration of electronic sensors...
  • Page 14: Appendix

     WARNING FASEP 2000 srl shall not be responsible for any inconvenience, breakdown, accidents caused directly or indirectly by unauthorized service. Service to any parts by unauthorized engineers will void warranty and will any right of the owner of the unit.
  • Page 15: C: Errors And Malfunctions Recognized By The Computer

    [when servicing the unit] Make sure power sources are disconnected before service on the unit is performed. Service to PCB, electrical and mechanical parts should be done only by an Authorized FASEP 2000 Service Center. Errors and Malfunctions recognized by the Computer Errors may apply to some model only.

This manual is also suitable for:

B103

Table of Contents