Download Print this page

Gastec 51L Instructions

Fluorochlorocarbons detector tube

Advertisement

Quick Links

GASTEC
No.51L
Instructions for
Fluorochlorocarbons Detector Tube
FOR SAFE OPERATION
:
Carefully read this manual and
the
instruction manual of your
Gastec
Gas
Sampling
Pump
and dedicated Gastec Pyrotec
Pyrolyzer
(No. 840).
&WARNING:
1.
Use
only Gastec detector tubes in a Gastec pump.
2.
Do not
interchange or
use
non-Gastec parts
or
components in Gastec's detector
tube
and
pump system.
3.
Using non-Gastec parts
or components
in Gastec's detector tube
and pump
system
or using
a non-Gastec detector tube with a
Gastec
pump or
using
a
Gastec detector tube with
a
non-
Gastec pump
may
damage
your detector
tube
and pump
system,
or may
cause
serious
injuries,
or
death
to
the
end-user.
It
will also
void all
warranties,
and guarantees regarding
performance and
data accuracy.
4. Do
not
operate Gastec Pyrotec Pyrolyzer
near
flammable liquids or in explosive
atmospheres.
Lt.
CAUTION
: If
you do
not
observe the
following precautions,
you
may
suffer
injuries or damage the product.
1.
When
breaking the tube ends, keep away from
eyes.
2.
Do not touch
the
broken glass tubes, pieces and reagent with bare hand(s).
3.
The
sampling
time
represents the
time
necessary to
draw the
air
sample
through
the
tube.
The
tube
must be positioned in
the desired
sampling area for
the
entire sampling time or
until
the flow finish indicator indicates the end of
the
sampling.
6.NOTES:
For maintaining performance
and
reliability
of
the test
results,
observe the following.
1.
Use Gastec Gas
Sampling Pump
together
with
Gastec Detector Tubes only for the
purposes
specified in
the instruction
manual of the
detector
tube.
2. Use this
tube
within
the
temperature range of 0 - 40'C (32- 104°F).
3. Use this
tube
within
the
relative humidity
range
of 0
-
90%.
4.
This tube
may be
interfered
with by
the
coexisting gases. Please
refer
to
the
table
"INTERFERENCES"
below.
5. Do
not
subject
Gastec
Pyrotec Pyrolyzer to strong vibrations or
shocks.
Damaged
filament
or
circuit failure may change pyrolysis
rate.
6. The shelf
life
and storage condition of the
tube
are marked on the label of the
tube
box.
APPLICATION
OF THE TUBE :
Use
this
tube for detecting Fluorochlorocarbons
in
the air or in industrial areas and for
determining the environmental atmospheric condition.
SPECIFICATION :
(Because of Gastec's commitment to continued
improvement,
specifications are subject to
change without notice.)
Scrubber
Agent
Measuring Range
1-20oom
20
-
54 ppm
Number ol Pump Stroke
2
1
Stroke Correction Factor
1
2.7
Sampling Time
2 minutes oer
oumo
stroke
Detecting Limit
0.2 ppm (n=2)
Colour Chanae
Yellow
-
Reddish ourole
Reaction Principle
Pyrotec
:
Fluorochlorocarbons -
HCL
Pyrotube
: HCI
+
Base
-
Chlorine
••
Shelf Life
:
Please refer to the validity date printed on the tube
box.
••
Store the tubes in a dark and cool place.
CORRECTION FOR TEMPERATURE, HUMIDITY
AND PRESSURE :
Temperature :
No correction
is required
between 0 - 40°C (32
-
104°F).
Humidity :
No correction
is
required between 0
-
90% R.H.
Pressure
:
To correct
for
pressure, use
the
formula below
Tube
Reading•
(ppm)
x
1013 (hPa)
Atmospheric Pressure (hPa)
*
This value
is
after other correction(s), if any, are applied.
MEASUREMENT PROCEDURE:
1. Set up Gastec Pyrotec
Pyrolyzer
and Gastec Gas Sampling Pump.
2.
For
checking
the
leakage of the pump and Gastec
Pyrotec
Pyrolyzer, insert a freshly sealed detector
tube
into
the
pump.
Follow
instructions provided with the pump and Gastec Pyrotec
Pyrolyzer operation manual.
3. Turn on Gastec
Pyrotec
Pyrolyzer and
wait
for two minutes.
4. Break tips off a fresh detector tube with the
tube
tip breaker in the
pump.
5.
Insert
the
tube
securely into Gastec
Pyrotec
Pyrolyzer with the
arrow
(G►)
on the tube pointing toward Gastec Pyrotec Pyrolyzer
(fig.
1).
6. Make certain
the
pump handle is all the
way
in. Align the guide
marks on the pump body with
the
guide marks on the handle.
T
ol l o
n.M!i
U-tube
.
........
,,,..,,
. .,,
deteclOf
tube
;
~
.
,
.....
~
()n.011
swtdo
~
S-
pump
fig.
1
7. Pull
the
handle all
the
way out until
it locks
at one pump stroke (100 ml). Wait two minutes
and confirm
the
completion of
the
sampling.
Repeat
the
above sampling procedure one more
time.
8. For measurements
higher
than 20 ppm, prepare a
fresh
tube and perform one pump stroke.

Advertisement

loading
Need help?

Need help?

Do you have a question about the 51L and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel