Download Print this page

NICOR PROTEUS XPL1B Installation Instructions

Hazardous location linear

Advertisement

Quick Links

GENERAL SAFETY:
To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions,
and other hazards, read all warning and instructions included with and on the fixture box and all fixture labels.
Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
Commercial installation, service and maintenance of luminaires should be performed by a qualified licensed electrician.
DO NOT INSTALL DAMAGED PRODUCT!
This fixture is intended to be connected to a properly installed and grounded UL listed junction box.
Make sure that the supply voltage is the same as the luminaire voltage.
Do not install where the marked operating temperatures exceed the ignition temperatures of the hazardous atmosphere.
Do not operate in ambient temperatures above those indicated on the luminaire nameplate
All gasket seals must be clean and undamaged
WARNING:
RISK OF ELECTRIC SHOCK
Turn off electrical power at the fuse or circuit breaker box before wiring fixture to the power supply.
Turn off the power when you perform any maintenance.
Verify that the supply voltage is correct by comparing it with luminaire label information.
Make all electrical and grounded connections in accordance with the NEC and any applicable local code requirements.
All wiring connections should be capped with UL approved wire connectors.
Luminaire must be supplied by a wiring system with an equipment grounding conductor.
CAUTION
RISK OF INJURY
Wear gloves and safety glasses at all times when removing luminaire from carton, installing servicing or performing maintenance.
Avoid direct eye expose to the light source while it is on
Account for small parts and destroy packing material as these may be hazardous to children.
CAUTION
RISK OF FIRE
Keep combustible and other materials that can burn away from
luminaires and lamp/lens. MIN 90°C CONDUCTORS
Operating Characteristics:
Rated Voltage: 100-240/277VAC, 50/60Hz
Ambient Temperature Range: -40°C (-40°F) ~ +50°C (122°F)
Environmental Ratings
Suitable for wet location
IP66
What's In The Box
One (1) XPL
NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107 P: 800.821.6283 F: 800.892.8393 www.nicorlighting.com November 12, 2018 1:39 PM rev 1.0
PROTEUS XPL1B Hazardous Location Linear
(and associated hardware)
One (1) 3/4" NPT plug
C1D2 INSTALLATION INSTRUCTIONS
This fixture is suitable for use in the following hazardous (classified)
areas as defined by the National Electrical Code (NEC) and Canadian
Electrical Code (CEC):
Hazardous Locations
Class I, Division 2, Groups A, B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
Compliances
UL 844
UL 1598
UL 1598A
CSA C22.2 No. 137-M1981
CSA C22.2 No. 250.0
CSA C22.2 No. 250.13
Refer to the luminaire name-plate for specific classification information,
maximum ambient temperature suitability and corresponding operating
temperature (T-Code).
Tools & Materials Needed
This fixture requires very few tools for installation: A drill a pair of
wire cutter/strippers, allen wrenches and appropriate mounting
hardware.

Advertisement

loading

Summary of Contents for NICOR PROTEUS XPL1B

  • Page 1 One (1) XPL (and associated hardware) One (1) 3/4” NPT plug NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107 P: 800.821.6283 F: 800.892.8393 www.nicorlighting.com November 12, 2018 1:39 PM rev 1.0...
  • Page 2 Adjust fixture to desired angle. Insert and tighten two (2) 3mm drive hex set-bolts (provided). Tighten the 6mm drive hex mounting bolts to set angle. NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107 P: 800.821.6283 F: 800.892.8393 www.nicorlighting.com November 12, 2018 1:39 PM rev 1.0...
  • Page 3 Check that all mechanical parts are properly assembled and secured. • Check that all electrical connections are clean, tight, and secure. NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107 P: 800.821.6283 F: 800.892.8393 www.nicorlighting.com November 12, 2018 1:39 PM rev 1.0...
  • Page 4 30 days of discovery of the defect, and return the product to NICOR for inspection. Once verified to be covered by this limited warranty, NICOR will, at its sole discretion, repair, replace, or refund the purchase price of...