Webster mini
INSTALLATION MANUAL
February 2024

Advertisement

Table of Contents
loading

Summary of Contents for Cansec Webster mini

  • Page 1 Webster mini INSTALLATION MANUAL February 2024...
  • Page 2: Table Of Contents

    Table of Contents Introduction................................... 3 Specifications ................................4 Webster mini Controller Layout ........................... 7 Panel Installation ................................ 9  Controller Power Connection ....................9  Entry Reader Wiring ......................11  Entry and Exit Reader Wiring .................... 11  Exit Button and Door Contact Wiring ................12 ...
  • Page 3: Introduction

    The Webster mini architecture has the ability to flash applications and firmware updates into the control panel using the Ethernet connection. The standard Webster mini is provisioned for only one door and 100,000 individual cardholders, using raw Wiegand data up to 64 bits per card ID. This allows the use of many proprietary Wiegand cards without the need for data conversion.
  • Page 4: Specifications

    Relative Humidity Operating ………………………………………………………..……………………… 20% to 80% Auto Resettable Fuses Webster mini Main 12V DC………………………………………………………………………1 A Reader Pair (Entry & Exit) ………………………………………………………………………1 A Output Relays (See note 2 in Appendix section) All Relays (2 per panel) Form ‘C’………..…………………………….SPDT 6 A @ 30 VDC Inputs Door Contact (1 per panel) ……………………………Requires normally closed contact...
  • Page 5 Webster mini Controller………….……………………………4.6” (W) x 3.35” (L) x 1.5” (D) [11.6 cm (W) x 8.5 cm (L) x 3.8 cm D)] Webster mini Enclosure …………………………………………..9.5" (W) x 13" (L) x 3" (D) [24.0 cm (W) x 33.0 cm (L) x 7.5 cm (D)] Controller Weight ...................
  • Page 6 Cansec accepts no responsibility for direct or consequential damages resulting from the failure of emergency lockdown functions which are dependant in any way on the operation of card readers, access control panels, communications networks, communications devices or host software.
  • Page 7: Webster Mini Controller Layout

    Webster mini Controller Layout Figure 1 Webster mini Page 7 of 29 Installation Manual February 2024 • Rev. 1.0...
  • Page 8 See Note 1 in Appendix section. 2. CAUTION: Do not unplug the Webster mini Power connector if the system is in operation as data corruption may occur on the Webster mini’s computer.
  • Page 9: Panel Installation

    However, it may be more cost effective to use a separate power supply (battery backed-up) just for the Webster mini controller and a separate power supply which can be sized to supply the amount of current that the attached high-current device e.g.
  • Page 10 Mode Indicator: After a complete power up the SHUTDN LED on the unit flashes green waiting for Webster to initialize and stays steady green when the initialization is finished ready for Figure 5 access via a web browser. Webster mini emits 2 beeps to indicate its operating mode. Webster 2 Beeps –...
  • Page 11: Entry Reader Wiring

    D0 (Green) of wires connected entry reader. to the reader port. *D0 (Green) of exit reader connects to D1 (White) of Figure 6 entry reader. Webster mini Page 11 of 29 Installation Manual February 2024 • Rev. 1.0...
  • Page 12: Exit Button And Door Contact Wiring

    Note: Both door contact and exit button inputs have voltage present on the circuits. Only connect dry contact devices to these inputs. Figure 7 The RTE/REX can be set to “Normally Open” or “Normally Closed” from the host software Figure 8 Webster mini Page 12 of 29 Installation Manual February 2024 • Rev. 1.0...
  • Page 13: Lock Output And Multi-Function Relay Wiring

     Door Operator_All – Activated on all cards (Lock Opens first).  Door Operator_HC – Activated on only Handicap cards (Lock Opens first).  DHO and Forced Entry – Activated on either DHO or Forced Entry. Webster mini Page 13 of 29 Installation Manual...
  • Page 14 Note: See Electric Strike Lock Wiring section additional MOV is required. Check for explanation of MF relay usage. with magnetic lock supplier. Webster mini Page 14 of 29 Installation Manual February 2024 • Rev. 1.0...
  • Page 15: Appendix

    3.63” x 5.88” x 2.5” Backup Battery 12 VDC 7 PA-SLP003 Amp Hour. Provides hours of (92.20mm x 149.35mm backup power for above power x 63.50mm) supplies. 5.00 lbs (2.27 kg) Webster mini Page 15 of 29 Installation Manual February 2024 • Rev. 1.0...
  • Page 16: Webster Mini System Indicators

    WEBSTER MINI SYSTEM INDICATORS 12VDC POWER LED: ON indicates 12 volts DC is connected.  Mode indicator: Webster mini emits 2 beeps after powered up. SHDN LED:  Flashing GREEN – PLM (Panel Logic Module) is waiting for Webster initialization to finish.
  • Page 17: Power Connector

    POWER CONNECTOR Figure 11 SHUTDN – SHUTDOWN BUTTON As the Webster mini contains a mini computer, a proper system shutdown is nesscessary to prevent data corruption. DO NOT simply unplug the power connector. To shut down follow this procedure: Figure 12 1.
  • Page 18: Ip Address Reset And Static Ip Address Configuration

    DHCP enabled. Existing database will not be reset or erased. 3. Note: The end of the reboot cycle is indicated by a Webster mini turning back on the associated system LEDs, and at the end it will emit 2 beeps.
  • Page 19 IP address range ready to be scanned. However, the IP address range can be manually modified accordingly. Figure 15 7. Click Scan to scan the network for all possible connected Webster mini panels. Figure 16 8. Double click on one of the detected panels or select it and click Configure.
  • Page 20 IP address of the host computer. Figure 17 10. The factory default or current password for a new unconfigured Webster mini panel is Cansec. The password must be changed to something else other than Cansec. 11. Click Save. The panel saves the new settings and reboots for the settings to take effect.
  • Page 21: Usb Ip Configuration Tool

    USB ports Figure 18 1. If the Webster mini controller is already powered off then proceed to step 3. Otherwise, press and hold the SHUTDN button until the SHDN LED on the module begins flashing rapidly then release the SHUTDN button.
  • Page 22 MAPCFG.txt created by the Webster mini controller during boot-up sequence. If the file is not present, repeat from step 1. Otherwise proceed to step 7. 7. A similar file will be displayed when opened in Notepad. Figure 19 Webster mini...
  • Page 23 Webster mini controller accepts data connection (SrvPort 5000) from only this host computer. Other connections on DiagPort 5001 and UpdatePort 5002 are not affected by this setting. Webster mini Page 23 of 29 Installation Manual February 2024 • Rev. 1.0...
  • Page 24 < USB INIT DONE > < USB INIT DONE > Please remove this line after this file has been correctly modified. The Webster mini controller reads parameters in this file during boot up sequence and configures the IP address accordingly after which it will write <USB INIT DONE>...
  • Page 25: Default Factory Static Ip Configuration

    Figure 21 2. The Webster mini controller will be reset and reboot with a default factory static IP address of 10.0.0.101. 3. Insert one end of your Ethernet cable (RJ45) to your computer and the other end of the cable to the Webster mini controller.
  • Page 26 6. Right click on your network adapter, in this example it’s Ethernet 2, and select Properties. Figure 24 7. Select Internet Protocol Version 4 (TCP/IPv4) and select Properties button. Webster mini Page 26 of 29 Installation Manual February 2024 • Rev. 1.0...
  • Page 27 8. Select Alternate Configuration and select User configured then enter the IP address of 10.0.0.200 followed by the Subnet mask of 255.255.255.0. When done select OK all the way out. Figure 26 Webster mini Page 27 of 29 Installation Manual February 2024 • Rev. 1.0...
  • Page 28: Forced Entry Output

    , will be activated if the door is forced open without either an access-granted or an exit-button event. A message will be transmitted to the host software if the panel is online. Webster mini Page 28 of 29 Installation Manual...
  • Page 29: Door Held Open Output

    The lock relay will be activated first followed by a one second pulse on this MF relay which is used to trigger the door operator. © Cansec Systems Ltd., 2024. All rights reserved Webster mini Page 29 of 29 Installation Manual February 2024 •...