LG DLEX8600BE Owner's Manual page 31

Hide thumbs Also See for DLEX8600BE:
Table of Contents

Advertisement

3
Press the Start/Pause button.
• The appliance will start the test, which will
last a few minutes. The heat will be turned
on and the temperatures in the drum will be
measured.
4
Check the display for results.
• During the test cycle, monitor the Flow
TM
Sense
display on the control panel. If the
TM
Flow Sense
LED has not turned on when
the cycle ends, the exhaust system is
adequate. If the exhaust system is severely
restricted, the Flow Sense
on. Other problems may also be shown with
error codes. See the chart for error code
details and solutions.
• If the Flow Sense
exhaust system is severely restricted, have
the system checked immediately, as
performance will be poor.
5
End of cycle.
• At the end of the test cycle, a message will
display. The test cycle will end and the
appliance will shut off automatically after a
short delay.
Check the Duct Condition
TM
If the Flow Sense
LED is turned on, check the
exhaust system for restrictions and damage.
Repair or replace the exhaust system as needed.
NOTE
• When the appliance is first installed, this test
should be performed to alert you to any existing
problems with the exhaust duct in your home.
However, since the test performed during
normal operation provides more accurate
information on the condition of the exhaust duct
than the installation test, the results during the
two tests may not be the same.
• Do not interrupt the test cycle, as this could
result in inaccurate results.
• Even if the LED doesn't light up during the test
cycle, some restrictions may still be present in
the exhaust system. Refer to the Venting the
Dryer section of this manual for complete
exhaust system and venting requirements.
TM
LED will turn
TM
LED indicates that the
Error Messages
Check the error message before you call for
service.
Error Message
Possible Cause & Solution
Temp sensor
Temperature sensor failure.
error 1
• Turn off the appliance and
call for service.
Humidity sensor
Humidity sensor failure.
error
• Turn off the appliance and
call for service.
High voltage
Electric dryer power cord is
Low voltage
not connected correctly, or
Power supply
house power supply is
incorrect.
• Reset circuit breaker or
replace fuse. Do not
increase the fuse capacity.
House fuse is blown, circuit
breaker has tripped, or
power outage has occurred.
• If the problem is a circuit
overload, have it corrected
by a qualified electrician.
Gas supply
Gas supply or service turned
off. (gas model only.)
• Confirm that house gas
shutoff and the dryer gas
shutoff are both fully
open.
Restricted or Blocked Airflow
Avoid long runs or runs with multiple elbows or
bends.
Excess or crushed
transition duct
INSTALLATION
31
Too many elbows or
exhaust too long

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dl x860 e series

Table of Contents