Lincoln Electric SQUARE WAVE TIG 355 Service Manual page 120

Hide thumbs Also See for SQUARE WAVE TIG 355:
Table of Contents

Advertisement

F-68
NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM
HIGH VOLTAGE / HIGH FREQUENCY can damage test equipment.
• Perform all voltage and waveform checks with high frequency circuit OFF.
TROUBLESHOOTING AND REPAIR
AC TIG MODE
CAUTION
50V
This is the typical AC output voltage
waveform generated from a properly
operating machine. Note that each
vertical division represents 50 volts
and that each horizontal division rep-
resents 2 milliseconds in time.
Note: Scope probes connected at
machine output terminals: (+) probe
to electrode terminal, (-) probe to
work terminal.
SCOPE SETTINGS
Volts/Div.....................50V/Div.
Horizontal Sweep .....2 ms/Div.
Coupling.............................DC
Trigger.........................Internal
SQUARE WAVE TIG 355
CH1
0 volts
2ms
F-68

Advertisement

Table of Contents
loading

Table of Contents