Energy storage system

Advertisement

Quick Links

Van Hall Innovations BV
De Huufkes 58
5674 TM NUENEN
The Netherlands
Tel 0031-40-2951099
info@vanhall-innovations.com
www.vanhall-innovations.com
Energy Storage System VH-5000L
User Manual
V1.2.2 (For VH-5000L firmware V1.2.2 or newer)

Advertisement

Table of Contents
loading

Summary of Contents for Van Hall Innovations VH-5000L

  • Page 1 Van Hall Innovations BV De Huufkes 58 5674 TM NUENEN The Netherlands Tel 0031-40-2951099 info@vanhall-innovations.com www.vanhall-innovations.com Energy Storage System VH-5000L User Manual V1.2.2 (For VH-5000L firmware V1.2.2 or newer)
  • Page 2: Description Of Products

    Description of products: VanHall Superbattery 10240Ah LiFePO4 Battery for Photovoltaic Energy Storage 5KW with RS485/RS232 Communication Port Model number: VH-5000L • Nominal voltage:51.2V • Nominal capacity:10240000mAh • Battery cell: 3.2V/100000mAh • Dimension:1020*600*180mm(Max) • Application: Energy storage system •...
  • Page 3 VAN HALL INNOVATION SUPERBATTERY Model Name: VH-5000L HYBRID SYSTEM Cell model:3.2V/100000mAh Battery specification: 3.2V/100000mAh /16S2P/51.2V/10240wh Nominal voltage:51.2V Nominal capacity:10240Wh Charging voltage: 58V Charging current: ≤80A Discharging current: ≤100A Instant discharging current: ≤200A End-off voltage: 42V Internal resistance: ≤200m Battery weight:80kg, Total Packing weight: 100kg Product dimension: 1020*600*180mm(Max)...
  • Page 4 2. Shock-resistant and dustproof: fill in the shock-resistant structure inside with cold rolling metal plate on which spray the powder to satisfy the requirements of shock-resistant and dustproof. 3. Communication interface: have RS485 / RS232 communication protocol and can read the information of battery voltage, current, temperature, capacity, etc.
  • Page 5 Schematic diagram of wire link:...
  • Page 6: Solar Panel

    Connect diagram of solar panel: Solar panel Total 12 pcs of 300-400W solar panels; Connect 3 solar panels in series as one group. And then connect 4 of such groups’ panel in parallel. Make the panels input voltage in the range of 60-115VDC. Quick Installation Guide for LCD Setting Program key parameters...
  • Page 7: Lcd Display Icons

    LCD Display Icons Icon Function description Input Source Information Indicates the AC input. Indicates the PV input Indicate input voltage, input frequency, PV voltage, battery voltage and charger current. Configuration Program and Fault Information Indicates the setting programs. Indicates the warning and fault codes. Warning: flashing with warning code.
  • Page 8: Load Information

    In battery mode, it will present battery capacity. Load Percentage Battery Voltage LCD Display < 1.717V/cell 1.717V/cell ~ 1.8V/cell Load >50% 1.8 ~ 1.883V/cell > 1.883 V/cell < 1.817V/cell 1.817V/cell ~ 1.9V/cell 50%> Load > 20% 1.9 ~ 1.983V/cell > 1.983 <...
  • Page 9: Lcd Setting

    LCD Setting After pressing and holding ENTER button for 5 seconds, the unit will enter setting mode. Press “UP” or “DOWN” button to select setting programs. And then, press “ENTER” button to confirm the selection or ESC button to exit. Setting Programs: Program Description...
  • Page 10 Available options in 1KVA 24V and 1KVA/3KVA 48V models: 20A (default) Maximum charging current: To configure total charging Available options in 2-3KVA 24V models: current for solar and utility chargers. 30A (default) (Max. charging current = utility charging current + solar charging current) Available options in 2-3KVA 24V/48V Plus models: 10A (Not available...
  • Page 11 100A 110A 120A 130A 140A Appliances (default) If selected, acceptable AC input voltage range will be within 90-280VAC. AC input voltage range If selected, acceptable AC input voltage range will be within 170-280VAC. Saving mode disable If disabled, no matter connected load (default) is low or high, the on/off status of inverter output will not be effected.
  • Page 12 Available options in 1KVA 12V/ 24V and 2KVA 24V Plus 120Vac model: 20A(default): Maximum utility charging current Available options in 2-3KVA 24V and 2-3KVA 24V Plus models: 30A (default) Available options in 1KVA/3KVA 48V and 2-3KVA 48V Plus models: 15A(default): Available options in 2KVA 48V Plus 120Vac model: 10A(default) Available options in 4KVA/5KVA models:...
  • Page 13 12.5V 12.8V Available options in 24V models: 22.0V 22.5V 23.0V (default) 23.5V 24.0V 24.5V 25.0V 25.5V Available options in 48V models: 46V (default) Below options only available for the model with 64VDC maximum charging voltage Setting voltage point back to utility source when selecting “SBU priority”...
  • Page 14 Setting voltage point back to utility source when selecting “SBU priority” or “Solar first” in program 01. Available options in 12V model: Battery fully charged 12.0V 12.3V 12.5V 12.8V 13.0V 13.3V 13.5V (default) 13.8V 14.0V Setting voltage point back to battery mode when selecting “SBU priority”...
  • Page 15 27.5V 28.5V Available options in 48V models: Battery fully charged 54V (default) Setting voltage point back to battery mode when selecting “SBU priority” or “Solar first” in program 01. Below options only available for the model with 64VDC maximum charging voltage...
  • Page 16 If this inverter/charger is working in Line, Standby or Fault mode, charger source can be programmed as below: Solar first Solar energy will charge battery as first priority. Utility will charge battery only when solar energy is not available. Utility first Utility will charge battery as first priority.
  • Page 17 12V model default setting: 14.1V 24V model default setting: 28.2V 48V model default setting: 56.4V Bulk charging voltage (C.V voltage) If self-defined is selected in program 5, this program can be set up. Setting range is from 12.0V to 14.6V for 12V model, 24.0V to 29.2V for 24V model and 48.0V to 58.4V for 48V model.
  • Page 18 If self-defined is selected in program 5, this program can be set up. Setting range is from 10.0V to 12.0V for 12V model, 20.0V to 24.0V for 24V model, 40.0V to 48.0V for 48V model. For the model with 64V maximum charging voltage, the setting range is from 40.0V to 54.0V.
  • Page 19: Display Setting

    Display Setting The LCD display information will be switched in turns by pressing “UP” or “DOWN” key. The selectable input voltage, input frequency, PV voltage, MPPT charging current, information is switched as below order: MPPT charging power, battery voltage, output voltage, output frequency, load percentage, load in VA, load in Watt, DC discharging current, main CPU Version and second CPU Version.
  • Page 20 Battery voltage=25.5V, discharging current=1A Battery voltage/ DC discharging current Output frequency=50Hz Output frequency Load percent=70% Load percentage When connected load is lower than 1kVA, load in VA will present xxxVA like below chart. Load in VA When load is larger than 1kVA (≧1KVA), load in VA will present x.xkVA like below chart.
  • Page 21 When load is lower than 1kW, load in W will present xxxW like below chart. Load in Watt When load is larger than 1kW (≧1KW), load in W will present x.xkW like below chart. Main CPU version 00014.04 Main CPU version checking Secondary CPU version 00003.03 Secondary CPU version checking...
  • Page 22: Operating Mode Description

    Operating Mode Description Operation mode Description LCD display Charging by utility and PV energy. Standby mode / Power saving mode Charging by utility. Note: *Standby mode: The inverter is No output is supplied by the not turned on yet but at this unit but it still can charge time, the inverter can charge batteries.
  • Page 23: Fault Reference Code

    Power from battery and PV energy. The unit will provide output Battery Mode power from battery and PV power. Power from battery only. Fault Reference Code Fault Code Fault Event Icon on Fan is locked when inverter is off. Over temperature Battery voltage is too high Battery voltage is too low Output short circuited or over temperature is detected...
  • Page 24: Warning Indicator

    Warning Indicator Warning Warning Event Audible Alarm Icon flashing Code Fan is locked when Beep three times every inverter is on. second Battery is over-charged Beep once every second Low battery Beep once every second Overload Beep once every 0.5 second Output power derating Beep twice every 3 seconds Solar charger stops due...
  • Page 25: Troubleshooting

    TROUBLE SHOOTING Problem LCD/LED/Buzzer Explanation / Possible cause What to do Unit shuts down LCD/LEDs and buzzer automatically will be active for 3 The battery voltage is too low 1. Re-charge battery. during startup seconds and then (<1.91V/Cell) 2. Replace battery. process.