Resonance Technology CinemaVision CV2020 Installation & Operation Manual

Mri audio/video patient comfort system

Advertisement

Quick Links

Installation / Operation Manual
CinemaVision CV2020
MRI Audio/Video
Patient Comfort System
Resonance Technology, Inc.
18121 Parthenia Street
Northridge, California 91325, USA
+1 (818) 882-1997
+1 (800) 428-MRTV
www.mrivideo.com
Innovative MRI-Compatible Entertainment Systems
Form: RTC-CV2020 Rev 0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CinemaVision CV2020 and is the answer not in the manual?

Questions and answers

Summary of Contents for Resonance Technology CinemaVision CV2020

  • Page 1 Installation / Operation Manual CinemaVision CV2020 MRI Audio/Video Patient Comfort System Resonance Technology, Inc. 18121 Parthenia Street Northridge, California 91325, USA +1 (818) 882-1997 +1 (800) 428-MRTV www.mrivideo.com Innovative MRI-Compatible Entertainment Systems Form: RTC-CV2020 Rev 0...
  • Page 2 No part of the document may be photocopied or reproduced without the prior written consent of Resonance Technology, Inc. Information contained in this document is covered by one or more of the following U.S. patents; [9,787,750], [5,877,732], [5,412,419], [5,627,902], [5,432,544], [9,571,820], [9,829,547], [9,979,938].
  • Page 3: Table Of Contents

    Enabling Stereoscopic 3D On Tablet Interface ....................... 27 6.8. Computer Settings Set up for Stereoscopic 3D ......................28 6.9. Patient Setup.................................. 31 6.10. Cleaning ..................................34 Troubleshooting ........................ 35 Specifications ........................37 Support Information ......................38 Resonance Technology, Inc. CV2020 Installation/Operation Manual RTC-CV2020 Rev 0...
  • Page 4: Introduction

    MRI scans. This installation/operation manual outlines how to properly install and operate the system. Thank you for choosing to purchase this system from Resonance Technology, Inc., the leader in fMRI and MRI patient comfort systems.
  • Page 5: Safety Information

    Safety Information 2. Safety Information At Resonance Technology, Inc., patient safety is our top priority. Please review this section completely as its contents are vital to the safety of the installer, the clinician/operator, and the patient. 2.1. Important Warnings for Patient and Operator Safety WARNING Prior to every use, inspect all system components that come in contact with the patient.
  • Page 6: Use Restrictions

    MRI suite. Resonance Technology, Inc. will not be held liable for any injuries or property damage which may occur as the result of improper use or installation of this product. By agreeing to this notice, users certify that they are familiar with basic safety procedures in an MRI room environment and that they have read and understand these safety precautions.
  • Page 7: General Warnings For Electronic Products

    CV2020 video monitor provided with the system. Do not disassemble this product. Only Resonance Technology, Inc. trained, and authorized personnel should perform all required service for this product. Failure to comply with this warning may result in property damage, injury and/or death from electric shock, fire, or other cause.
  • Page 8: Medical Device Safety Approvals

    Safety Information 2.7. Medical Device Safety Approvals The CV2020 System has the following safety certifications: Page 5 Resonance Technology, Inc. CV2020 Installation/Operation Manual RTC-CV2020 Rev 0...
  • Page 9: Installation Materials

    Controller Magnet Room RTC-551-070-124-000 CV2020 Video Goggle Magnet Room Slim Softshell [round] Headset RTC-650-067-000-XXX with headband Magnet Room RTC-650-051-000-001 CV2020 Transducer MR Pen Cabinet CV2020 Transducer Power RTC-750-301-xxx-xxx Supply Page 6 Resonance Technology, Inc. CV2020 Installation/Operation Manual RTC-CV2020 Rev 0...
  • Page 10 Installed in MRI Suite Pen panel cabinets to 5-pin Round Female to 5-pin Round Female Cable RTC-101-239-001-001 Transducer Location (12M/39ft) MRI Suite / Control Room RTC-101-306-003-000 Hospital Grade AC Power Cord Page 7 Resonance Technology, Inc. CV2020 Installation/Operation Manual RTC-CV2020 Rev 0...
  • Page 11: Room Layout Overview For Installation

    Additionally, these components should be placed in an area with no heavy foot traffic to keep them from being damaged. Page 8 Resonance Technology, Inc. CV2020 Installation/Operation Manual RTC-CV2020 Rev 0...
  • Page 12 Fiber Optic Cable (50m / 150’) CV2020 Transducer Transducer Power Supply Fiber Optics Wave Guide Penetration RTC recommends installing the Panel Transducer Power Supply In the MRI Pen Cabinet Page 9 Resonance Technology, Inc. CV2020 Installation/Operation Manual RTC-CV2020 Rev 0...
  • Page 13: Installation Procedure

    Before you begin the installation, determine the location where the transducer will be installed. It should be a secure area next to the magnet and away from heavy foot traffic. Please refer to the photo below for typical placement: Audio Video Headset Goggles Transducer Page 10 Resonance Technology, Inc. CV2020 Installation/Operation Manual RTC-CV2020 Rev 0...
  • Page 14: Installing The Transducer Power Supply

    (WLPS) into the MRI suite. It is imperative you must properly follow these instructions when installing the Linear Power Supply in the MRI Suite. To stay furthest possible position from the MRI bore, must walk along the wall of the MRI suite as illustrated below. Page 11 Resonance Technology, Inc. CV2020 Installation/Operation Manual RTC-CV2020 Rev 0...
  • Page 15: Installing The Mr Laser Link Cable And Transducer Power Supply Cables

    Transducer location. Route the remaining transducer power cable from the power supply location to the Transducer can be along the floor or thru the ceiling tiles. When using tools in the MRI, be sure to verify they are non-ferrous (Non-Magnetic). Page 12 Resonance Technology, Inc. CV2020 Installation/Operation Manual RTC-CV2020 Rev 0...
  • Page 16: Magnet Room Component Interconnection

    Connect the Fiber Optic cable, Power Supply cable and Visor to the Transducer. CV2020 Visor Slim Softshell Headset CV2020 Transducer Top View MRI Compatible Transducer Power Supply Fiber Optic Connection Page 13 Resonance Technology, Inc. CV2020 Installation/Operation Manual RTC-CV2020 Rev 0...
  • Page 17: Controller Connection

    Note: All connections have to be made for the CV 2020 System to work. At minimum, Power connection to wall, Fiber optic connection for communication and a single Video/Audio source. Page 14 Resonance Technology, Inc. CV2020 Installation/Operation Manual RTC-CV2020 Rev 0...
  • Page 18: Tech Tablet Remote Connections

    The control room speakers are connected to the Controller back panel. The Speakers required their own power supply and is supplies via USB 5v Wall plug. Mini Stereo connection to Controller Rear Panel “SYS USB Wall Power ” AUDIO OUT Connection Page 15 Resonance Technology, Inc. CV2020 Installation/Operation Manual RTC-CV2020 Rev 0...
  • Page 19: Stereoscopic 3D Connections

    Front of the CV2020 Controller and the HDMI output on the back side of the Controller two monitors can be plugged in to set up the computer setting. CPU not supplied by RTC CV2020 Controller Rear CPU Tower with Graphics Card Installed CV2020 Controller Front Panel Page 16 Resonance Technology, Inc. CV2020 Installation/Operation Manual RTC-CV2020 Rev 0...
  • Page 20: Operation

    Twist black ring clockwise to increases the control room volume. Twist black ring counterclockwise to decreases the control room volume. Press the center button to mute Control Room volume Page 17 Resonance Technology, Inc. CV2020 Installation/Operation Manual RTC-CV2020 Rev 0...
  • Page 21 Patient Visor video Video Source Audio level/Sound bar Home Screen Menu/Configuration Button Media Sources Sync Icon Audio source selection Alert Bell for patient Headset Control Room Camera (currently disabled) Page 18 Resonance Technology, Inc. CV2020 Installation/Operation Manual RTC-CV2020 Rev 0...
  • Page 22 Show clock button when pressed had a timer pop up at the bottom of the navigator app screen. The “reset link” button is currently disabled/inactive. Start button Reset button starts timer resets timer to “0” Page 19 Resonance Technology, Inc. CV2020 Installation/Operation Manual RTC-CV2020 Rev 0...
  • Page 23 Enables “Analog Mic” when blue. Disabled when grey. Eyetracker Camera features are still being developed and currently not active selections. Brightness Controls: option 1 or 2 on LED brightness intensity. Page 20 Resonance Technology, Inc. CV2020 Installation/Operation Manual RTC-CV2020 Rev 0...
  • Page 24 OLEDs or imprint image onto the displays by showing the same screen for a long period of time. Controls image brightness on the patient worn visor. Control features are currently disabled/ not active selections. Page 21 Resonance Technology, Inc. CV2020 Installation/Operation Manual RTC-CV2020 Rev 0...
  • Page 25: Playing Movie On The Navigator App

    Once you press the “Source” a pop up menu will be displayed on the right side of the tablet display. Once you select the desired movie it should automatically show up on the “Preview” side of the tablet display. Page 22 Resonance Technology, Inc. CV2020 Installation/Operation Manual RTC-CV2020 Rev 0...
  • Page 26 Patient” button gives you the ability to send the Video in the Preview screen to the Patient visor and can also be seen on the right side of the tablet display under “Patient”. Video Video Preview currently Window present on the Patient Visor Page 23 Resonance Technology, Inc. CV2020 Installation/Operation Manual RTC-CV2020 Rev 0...
  • Page 27: Movie Playback

    This shows when the volume adjustment knobs are adjusted or when the mute/push to talk button is pressed. When the center button is pressed the icon turns red. Page 24 Resonance Technology, Inc. CV2020 Installation/Operation Manual RTC-CV2020 Rev 0...
  • Page 28: Synchronization Bell

    Controller Communications = Controller is powered on and connected to the Tablet Interface. Controller HDMI Link = Controller and Tablet Interface HDMI Connection is present Transducer Communications = Transducer is powered on and connected properly with fiber optic cable Page 25 Resonance Technology, Inc. CV2020 Installation/Operation Manual RTC-CV2020 Rev 0...
  • Page 29: Audio Source For Headset

    External Audio/Video Sources: When utilizing the HDMI inputs on the Controller for example using an External DVD Player, the Analog Microphone needs to be activated to enable the 2-way communication. Page 26 Resonance Technology, Inc. CV2020 Installation/Operation Manual RTC-CV2020 Rev 0...
  • Page 30: Enabling Stereoscopic 3D On Tablet Interface

    (stereo) signal to the visor by selecting the “Source” button  then select “HDMI”  then select “Front Stereo” to have the stereoscopic image on the visor video. Page 27 Resonance Technology, Inc. CV2020 Installation/Operation Manual RTC-CV2020 Rev 0...
  • Page 31: Computer Settings Set Up For Stereoscopic 3D

    4. On the right and under workstation select Set Up Mosaic. And select Create New Configuration. 5. A new window will pop open, make sure that the Number of displays is set to 2 and the Topology is set to 1×2. Then click Next. Page 28 Resonance Technology, Inc. CV2020 Installation/Operation Manual RTC-CV2020 Rev 0...
  • Page 32 7. In the new window, set Refresh Rate to 60Hz. and Resolution per Display to 1920×1080. click Next. 8. In the left white box write 1, and on the right white box write 2. Then hit Apply. Page 29 Resonance Technology, Inc. CV2020 Installation/Operation Manual RTC-CV2020 Rev 0...
  • Page 33 11. To disable the Mosaic configuration at any time, simply hit on Disable on the Mosaic Set-up window, the configuration will disable. Note that if you want to re-activate the Mosaic, you have to run the set-up from the beginning, steps 3-10. Page 30 Resonance Technology, Inc. CV2020 Installation/Operation Manual RTC-CV2020 Rev 0...
  • Page 34: Patient Setup

    Your patient is now ready for your scan procedure. Note: Resonance Technology, Inc. recommends a visual inspection of the visor/headset signal jackets or portions that touch the patient for any breakage or uncleanliness. Any signs damage contact RTC in order to arrange servicing of the item.
  • Page 35 Caution: Any changes to the RTC default settings can result in loss of video and/or audio. Please Call Technical Support if you experience any problems with your CV2020 System. Page 32 Resonance Technology, Inc. CV2020 Installation/Operation Manual RTC-CV2020 Rev 0...
  • Page 36 6.9.5.2. Fit the patient’s head all the way into the coil and slide the Video Goggles down to fit the patient’s eyes. Place the patient’s head all the way into the head coil. Page 33 Resonance Technology, Inc. CV2020 Installation/Operation Manual RTC-CV2020 Rev 0...
  • Page 37: Cleaning

    6.10. Cleaning For cleaning and disinfecting purposes, Resonance Technology, Inc. recommends using alcohol-free, non- flammable, and non-corrosive cleaning wipes or mild detergent on the video goggles, mask, and audio headset components (ear cushions/cable jacket). Do not use any harsh chemicals on the Visor protective lenses;...
  • Page 38: Troubleshooting

    If the problem arises inside the Magnet Room area: NOTE: Turn off the Transducer Power Supply to prevent damage to the system components, when plugging in or unplugging the power supply cable, headset, and/or video goggles. Page 35 Resonance Technology, Inc. CV2020 Installation/Operation Manual RTC-CV2020 Rev 0...
  • Page 39 If the system still does not respond, check synchronization by selecting the “Bell” icon on the RTC App home  page to see if there is any issue with system connections. If the system still does not respond, please contact Resonance Technology, Inc. for assistance.  Page 36 Resonance Technology, Inc.
  • Page 40: Specifications

     10°C - 40°C Relative Humidity  30-75 % ATM Pressure Exposure  700 – 1060 hPa Below is the Medical Device Safety Test Certificate for the CV2020 System: Page 37 Resonance Technology, Inc. CV2020 Installation/Operation Manual RTC-CV2020 Rev 0...
  • Page 41: Support Information

    Friday 8 A.M. to 5 P.M., Pacific Standard Time (USA) at +1 (818) 882-1997, or e-mail to support@mrivideo.com. Resonance Technology, Inc. Product Recycling Program: Resonance Technology Inc. actively supports the protection of the environment by efficiently recycling all our electronic products. Our everyday pollution prevention activities reduce the need for electronic waste to go into landfills.
  • Page 42 Notes Page 39 Resonance Technology, Inc. CV2020 Installation/Operation Manual RTC-CV2020 Rev 0...