Do you have a question about the GSMessenger and is the answer not in the manual?
Questions and answers
Summary of Contents for El.Mo GSMessenger
Page 1
GSM telephone dialer model GSMessenger TECHNICAL MANUAL...
Page 2
Some products carry back-up rechargeable or disposable batteries. If not properly connected, batteries could damage the product, other objects and en- danger the system's operator (explosion and fire). Installer’s stamp: 2 - GSMessenger - TECHNICAL MANUAL...
(GSM connection status, fault and power supply) and the built-in buzzer that supports programming ope- rations, this devices offers a simple and intuitive user interface. - The GSMessenger can store 4 voice messages (up to 13 sec. long) and each message can be linked to a specific input.
User interface: 16-key rubber keypad. In compliance with the 89/336/EEC EMC directive, the GSMessenger dialer has been tested and found to comply with the EN 50130-4:1995 + A:1998 standards concerning electromagnetic immunity and the EN 50081-1:1992 standards concerning electromagnetic emission. The LVD73/23/EEC directive requirements concerning electrical safety have been complied with through tests performed in compliance with the EN 60950:2000-06 standard.
- Open the dialer's housing following the instructions supplied in this manual. - Insert the SIM card to be used with the GSMessenger into a cellular phone to check that it is not program- med to request a PIN code when it is switched on. Remove any optional services.
Page 6
- Mount the back of the GSMessenger on the selected support making sure that it is sturdy and that it is not subject to vibrations. Make sure that the wall behind the unit does not yield under the pressure of the tamper-proof spring.
Page 7
Dismantling of the card. GSMessenger - TECHNICAL MANUAL - 7...
Page 8
Drill holes marking for mounting. Mounting of the card 8 - GSMessenger - TECHNICAL MANUAL...
SIM slot located under the keypad.The SIM card must not be removed or inserted into the device while it is on. Should this happen, the GSMessenger could become inoperate for up to 3 minutes, until it is reset or turned off and on again.
Page 10
TEST call is programmed. By programming input no. 4 to externally disable telephone calls you will not disable the dial out TEST function. Special care must be taken while programming the GSMessenger in order not to disable the previously exe- cuted connections.
Page 11
Example of a mixed connections involving an intrusion and a fire detection system. GSMessenger - TECHNICAL MANUAL - 11...
Label summing up main keypad functions. refer to following page for details on the range of The installer must attach this adhesive label information displayed. that is supplied with the device to the door of the dialer. 12 - GSMessenger - TECHNICAL MANUAL...
CAUTION: during the reset to factory default settings procedure, the inputs will not be checked, transmission procedures are not enabled and any transmission in progress will be aborted. At the end of the default resetting procedure the programmed settings of the GSMessenger will be as fol- lows: - Voice calls repetitions:...
8. PROGRAMMING Through the keypad of the GSMessenger the dialer can be fully and effortlessly programmed with the sup- port of audio prompts and displayed indications. Each time a key is pressed, the built-in buzzer will beep. Two beeps will be heard to confirm a command that has been completely entered, while four beeps will be heard when the programming has been successfully stored.
The syntax of the command is as follows: 8.7 To program telephone numbers for SMS messages As described in the dialer's features and later in Chapter "Operations", the GSMessenger is able to send SMS messages. The syntax of the command is as follows: 8.8 To record voice messages...
8.12 To display the number of programmed voice calls To check the number of call repetitions that have been set, the appropriate command must be entered using the following syntax: GSMessenger - TECHNICAL MANUAL - 17...
NOTE: it is strongly recommended to program a transmission time that is adequate with the average habits of the subscriber to be called in order to avoid that the subscriber picks up the phone when the transmission time has expired. 18 - GSMessenger - TECHNICAL MANUAL...
8.17 To program the periodic TEST transmission duration The GSMessenger can be programmed to make a voice call at regular intervals in order to check the credit balance of a SIM card. The call is made using the phone number of the first subscriber that is stored in the memory position No. 4 while the message being sent is the message No.
Checking the prepaid SIM card credit status is not longer possible since the different providers do not supply this service in an automatic fashion that can be used by the GSMessenger. The only way to obtain this infor- mation is to set the periodic transmission of the SMS message "CHECK SIM EXPITY DATE AND CREDIT BA- LANCE".
8.23 To program the response delay of input no. 2 The delayed response of input no. 2 has been designed to allow the connection of the GSMessenger to control units that may not have been produced recently and whose alarm relay could be momentarily triggered.
The built-in controller of the GSMessenger will generate a warming message and send it as an SMS mes- sage to all the stored phone numbers should there be a continuous and abnormal external power supply failure.
8.31 To display the programmed telephone remote control function The syntax of the command is as follows: NOTE: if the fault relay is set for the telephone remote control function, the GSMessenger will no longer report its operating condition. 8.32 To set the relay condition (for remote controllable relay only) Relay condition can be set from the keyboard only if the relay is set as remote controllable (*86# keys).
8.33 To display the relay condition settings (for remote controllable relay only) The syntax of the command is as follows: The GSMessenger display will show the programming status for 2 seconds. 8.34 To program the number of SMS transmissions triggered by an event The meaning of the command is the same of the equivalent command for the voice transmission.
To check the settings, the appropriate command must be entered using the following syntax: 9. STORED SMS MESSAGES The GSMessenger dialer is supplied with a set of 12 SMS messages which enable its standard operation on the field. This set of messages cannot be changed by the installer.
In order to operate the device correctly, the following items must be carefully evaluated: - The GSMessenger has been designed and developed to be used for security applications. The use of prepaid SIM cards is to be avoided as much as possible when employing the device for security applica- tions.
. - The GSMessenger can detect the outcome of a call made to busy GSM terminals. Even if only one number has been busy during all the cycles of the dialer's dialing sequences, the unit will carry out at least 3 extra cycles dialing only the numbers that were constantly found busy.
10.6 Periodic TEST call The GSMessenger can be programmed to send a periodic voice call to check the credit balance on the SIM card. The call is made using the first subscriber's number stored in the memory position no. 4.
Telephone remote control procedure: 1. Call the GSMessenger using a remote telephone able to transmit DTMF tones. 2. The GSMessenger responds after 1 or 2 rings and transmits two beeps to report that it awaits the access code. 3. Enter the six digit access code.
During the installation and maintenance of the device, it is useful to have an indication of the GSM signal strength. Please carry out the following procedure to display the strength of the GSM signal: 30 - GSMessenger - TECHNICAL MANUAL...
11. WHAT TO DO IF ..QUESTIONS AND ANSWERS Q = The GSMessenger reports the lack of GSM registration by turning on the LED of module and by showing a flashing letter "A" on the display: A = Check that the SIM card has been properly inserted.
Page 32
A = The telephone remote function to activate the fault relay does not foresee the option for a scheduled activation. The activation/deactivation of the relay can be controlled manually thereby determining also its time frame based on the operation that is required from the device controlled by the GSMessenger. 32 - GSMessenger - TECHNICAL MANUAL...
12. DISPOSAL INSTRUCTIONS Dispose of the GSMessenger in compliance with current city regulations and by leaving the device in a dum- ping ground that is authorized for the disposal of electronic products. If required, please contact the appropriate city office for additional information.
Periodic TEST call ..............28 GSMessenger - TECHNICAL MANUAL - 35...
Page 36
Fault relay ................28 Telephone remote control of a device connected to the GSMessenger ......29 To display the status of the inputs .
Need help?
Do you have a question about the GSMessenger and is the answer not in the manual?
Questions and answers