Government Requirements for the United Kingdom
Document Number 3920-A2-GK45-10
November 1996
Overview
This document highlights government requirements, safety warnings, installation procedures, and functions that
are unique to COMSPHERE 3900 Series modems installed within the United Kingdom. This document is
intended to be used in conjunction with the COMSPHERE 392xPlus Modems, Models 3920Plus and 3921Plus,
Installation and Operation Manual, Document No. 3920-A2-GN31. Please consult this Installation and
Operation Manual for overall operation of the 3900 Series modem.
Government Requirements for the United Kingdom
Connection to Supply Mains
IMPORTANT: The wires in the mains lead supplied with this equipment are coloured in accordance with the
following code:
As the colours of the cores in the mains lead of this equipment may not correspond with the coloured markings
identifying the terminals in your plug, proceed as follows:
The core which is coloured green and yellow must be connected to the terminal in the plug which is
marked with the letter E or by the earth symbol
The core which is coloured blue must be connected to the terminal which is marked with the letter N or
coloured black.
The core which is coloured brown must be connected to the terminal which is marked with the letter L or
coloured red.
For pluggable equipment, the mains socket outlet shall be installed near the equipment and be easily accessible.
TM
Green and Yellow — Earth
Blue
— Neutral
Brown
— Live
SAFETY WARNING
This equipment must be earthed.
1
, or coloured green and yellow.

Advertisement

loading

Summary of Contents for Paradyne COMSPHERE 3920Plus

  • Page 1 COMSPHERE 3900 Series modems installed within the United Kingdom. This document is intended to be used in conjunction with the COMSPHERE 392xPlus Modems, Models 3920Plus and 3921Plus, Installation and Operation Manual, Document No. 3920-A2-GN31. Please consult this Installation and Operation Manual for overall operation of the 3900 Series modem.
  • Page 2 Interconnection circuits between this modem and any other equipment should be such that the equipment continues to comply with the requirements of clause 4.2 of EN41003 for TNV (Telephone Network Voltage) circuits and clause 2.3 of EN60950 for SELV (Safety Extra Low Voltage) circuits after making connection between circuits.

This manual is also suitable for:

3921plusComsphere 3900 seriesComsphere 3921plus