Paradyne COMSPHERE 3910 Regulatory Information page 9

Comsphere 3900 series government requirements for great britain
Hide thumbs Also See for COMSPHERE 3910:
Table of Contents

Advertisement

Line Dialer Configuration Options for the United Kingdom
Blind Dial Paus: 2sec
Nxt 2sec
Blind Dial Pause. Set to 2 seconds. Read-only and cannot be changed. Only appears when Dial Tone
Detect is disabled.
The AT command is S6=2 and cannot be changed.
Auto Make Busy: Disable
Nxt Disable
Auto Make Busy. Set to Disable. Read-only and cannot be changed. Only appears when using Model 3911
modems.
The AT command is S40=0 and cannot be changed.
MakeBusyVia DTR: Disable
Nxt Disable
Make Busy Via DTR. Set to Disable. Read-only and cannot be changed.
The AT command is S69=0 and cannot be changed.
Dial Line Configuration Options for the United Kingdom
Dial Line Rate: 14400(V32b)
Nxt 14400(V32b) 12000(V32b) 9600(V32b) 7200(V32b) 4800(V32b) 2400(V22bis) 1200(V22)
0–300(V21)
Dial Line Rate. Does not support the Bell modulation schemes of 1200 (212A) and 0–300 (103J).
The factory default is 14400(V32b)
AT command for Dial Line Rate is S-Register S41= n , where n is:
1 = 14,400 (V.32 bis)
2 = 12,000 (V.32 bis)
3 = 9600 (V.32 bis/V.32)
4 = 7200 (V.32 bis)
Dial TX Level: –9 dBm
Nxt –9 dBm
Dial Transmit Level. Set to –9 dBm. Read-only and cannot be changed.
The AT commands are &I9 and &J11 and cannot be changed.
V22b Guard Tone: 1800 Hz
Nxt 1800 Hz
V.22 bis Guard Tone. Set to 1800 Hz. Read-only and cannot be changed.
The AT command is &G2 and cannot be changed.
Table 3
Table 4
5 = 4800 (V.32 bis/V.32)
6 = 2400 (V.22 bis)
7 = 1200 (V.22)
10 = 0–300 (V.21)
8