Paradyne COMSPHERE 3910 Installation Instructions Manual page 12

Comsphere 3900 series
Hide thumbs Also See for COMSPHERE 3910:
Table of Contents

Advertisement

To change a factory template using AT commands, perform the following steps. For more information on
changing factory templates using AT commands, refer to Chapter 5, AT Command Set and S-Registers, in
Document No. 3910-A2-GN32.
1. Use the AT&F&W command to load the appropriate factory configuration to the appropriate storage
area. Enter the following:
TYPE:
AT&Fy&Wn
Where:
y is one of the Factory configurations. For example:
0 for Async Dial
1 for Sync Dial
2 for Sync Leased (Answer)
3 for UNIX Dial
4 for Sync Leased (Originate)
5 for Async Leased (Answer)
6 for Async Leased (Originate)
7 for TMp (Control)
8 for TMp (Trib)
&F0 and &F3 allow you to use AT commands after saving a factory
configuration. Other selections remove AT command control. The
only way to return to AT command control is through the DCP as
described earlier in Using the DCP .
Where:
n is one of the following storage areas:
0 for Active (Saved)
1 for Customer 1
2 for Customer 2
These three configuration areas are nonvolatile memory locations.
Active (Saved) contains the most recently saved changes to any
configuration options. In the event of power loss, the modem
retrieves these configuration options. Customer 1 and Customer 2
are user-defined configuration areas.
PRESS:
Return (Enter)
2. The selected factory configuration is saved.
To establish a connection with a remote modem, use the D (Dial) command. For more information on AT
commands, refer to Chapter 5, AT Commands and S-Registers, in Document No. 3910-A2-GN32.
NOTE
NOTE
12

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comsphere 3911

Table of Contents