Solvimus MUC.one Series User Manual

Data concentrator for smart metering
Table of Contents

Advertisement

Quick Links

MUC.ONE - USER MANUAL
MUC.one
Data concentrator
for
Smart Metering
Version: 1.0
Date: 21 December 2023
Firmware Version 1.36
Authors:
Remo Reichel, Frank Richter
solvimus GmbH
Ratsteichstr. 5
98693 Ilmenau
Germany
solvimus GmbH – Ratsteichstr. 5 – 98693 Ilmenau – Germany
Telephone: +49 3677 7613060 – Fax: +49 3677 7613069 – E-Mail: info@solvimus.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MUC.one Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Solvimus MUC.one Series

  • Page 1 Date: 21 December 2023 Firmware Version 1.36 Authors: Remo Reichel, Frank Richter solvimus GmbH Ratsteichstr. 5 98693 Ilmenau Germany solvimus GmbH – Ratsteichstr. 5 – 98693 Ilmenau – Germany Telephone: +49 3677 7613060 – Fax: +49 3677 7613069 – E-Mail: info@solvimus.de...
  • Page 2 MUC.one - User manual Page intentionally left blank Page 2/88 Version: 1.0 Frank Richter, 21 December 2023 UG_EN_MUCone.pdf Released © solvimus GmbH...
  • Page 3: Table Of Contents

    4.2 Tab General ..........Frank Richter, 21 December 2023 Version: 1.0 Page 3/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 4 Command line ........Page 4/88 Version: 1.0 Frank Richter, 21 December 2023 UG_EN_MUCone.pdf Released © solvimus GmbH...
  • Page 5 8.6 Media types, measurement types and units ......9 Accessory Frank Richter, 21 December 2023 Version: 1.0 Page 5/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 6: Notes And Conventions

    GmbH. Violations will result in a claim for damages. The solvimus GmbH reserves the right to provide for any alterations or modifications that serve to increase the efficiency of technical progress. All rights in the event of the granting of a patent or the protection of a utility model are reserved by solvimus GmbH.
  • Page 7: Symbols

    Numbers a noted according to this table: Numbering system Example Comments Decimal Normal notation Hexadecimal 0x64 C-like notation Binary ’100’ In apostrophes ’0110.0100’ Nibbles separated by dots Table 1: Numbering systems Frank Richter, 21 December 2023 Version: 1.0 Page 7/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 8: Safety Guidelines

    When handling the components, ensure that everything in the vicinity is well earthed (personnel, work- place and packaging). Do not touch electrically conductive components, e.g. data contacts. 1.7 Scope This documentation describes the device manufactured by solvimus GmbH, Ilmenau, and stated on the title page. 1.8 Abbreviations...
  • Page 9 Open Metering System Password Authentication Protocol Privacy Enhanced Mail Personal Identification Number Public Key Infrastructure Programmable Logic Controller PLMN Public Land Mobile Network Continued on next page Frank Richter, 21 December 2023 Version: 1.0 Page 9/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 10 WLAN Wireless Local Area Network wM-Bus Wireless Meter-Bus (EN 13757, part 3, 4 and 7) eXtensible Markup Language XSLT eXtensible Stylesheet Language Transformation Table 2: Abbreviations Page 10/88 Version: 1.0 Frank Richter, 21 December 2023 UG_EN_MUCone.pdf Released © solvimus GmbH...
  • Page 11: Introducing The Device

    The MUC.one is a MUC-Controller and is intended for wall mounting. The serial number of the devices of the solvimus GmbH can be read from the housing. 2.2 Delivery variants The MUC.one is offered in two variants, and so can easily be adapted to the requirements of the particular...
  • Page 12: Status Leds

    SIM card in the open card holder, and on the right the SIM card in the closed card holder. The chip of the SIM card is downward facing. Page 12/88 Version: 1.0 Frank Richter, 21 December 2023 UG_EN_MUCone.pdf Released © solvimus GmbH...
  • Page 13: Power Supply

    An internet connection is required on the PC to launch the website, as the web framework needs to be loaded. For offline operation, solvimus GmbH can provide a tool for Windows to load the web framework from a local PC.
  • Page 14: Specific Troubleshooting

    Replace the faulty cable if necessary. If errors could not be eliminated, please contact our customer support: E-Mail: support@solvimus.de Phone: +49 3677 7613065 Page 14/88 Version: 1.0 Frank Richter, 21 December 2023 UG_EN_MUCone.pdf Released © solvimus GmbH...
  • Page 15: Typical Application Scenarios

    • Temperature range for operation: 0..50 °C (daily average) • Temperature range for transport and storage: -20..70 °C (short-time) • Air humidity: 0..95 % relH, non-condensing • Degree of protection: IP67 (IEC 60529) Frank Richter, 21 December 2023 Version: 1.0 Page 15/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 16: Electrical Specifications

    * Directly at modem without losses in cables, plugs respectively without antenna gain Table 7: WLAN input power in receive mode • Mobile radio: NB-IoT modem, LTE Cat-NB, internal antenna, card holder for micro SIM card, supported bands: Page 16/88 Version: 1.0 Frank Richter, 21 December 2023 UG_EN_MUCone.pdf Released © solvimus GmbH...
  • Page 17: Further Specifications

    • CPU: 32-Bit LX7, up to 240 MHz clock frequency • Memory: 320 kB RAM, 4 MB Flash • Operating system: FreeRTOS • Integrated RTC: backed-up for up to 7 days Frank Richter, 21 December 2023 Version: 1.0 Page 17/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 18: Tool Netdiscover

    3.2 Discovering and accessing devices After the tool is started, it uses UDP broadcast via UDP port 8001 to discover all devices from solvimus GmbH accessible in the local network and displays them in the main window.
  • Page 19: Network Configuration

    Thus, IP address, subnet mask or gateway address can be changed to static or DHCP can be activated for obtaining these settings automatically from a DHCP server. Frank Richter, 21 December 2023 Version: 1.0 Page 19/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 20: Access To The Web-Based Front End Via Http

    3.5 Access to the file system via FTP The devices from solvimus GmbH can be accessed via FTP to work directly on the file system level. This enables updates, special configurations and extended functionality (see Chapter 8). The integrated FTP server of the devices supports both FTP and SFTP.
  • Page 21 SFTP, its authenticity is checked using stored certificates. Normally, the devices from solvimus GmbH are coming with an individual, self-signed certificate upon delivery. This certificate is usually classified as untrusted by your PC. Therefore, a security prompt with information about the device’s certificate is displayed.
  • Page 22: Access To The Command Line Via Ssh

    When a connection is established to a specific device with SSH, its authenticity is checked using stored certifi- cates. Normally, the devices from solvimus GmbH are coming with an individual, self-signed certificate upon delivery. This certificate is usually classified as untrusted by your PC. Therefore, a security prompt with infor- mation about the device’s certificate is displayed.
  • Page 23: Mass Deployment

    The configuration or update should explicitly only be deployed on similar devices. In this case mark the devices in the tool Netdiscover on which you want to perform a configuration or firmware update in parallel. Frank Richter, 21 December 2023 Version: 1.0 Page 23/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 24 An update of the firmware is also possible via the web site as described in Section 4.10. The file is processed on the device after the upload. The device is then restarted. Page 24/88 Version: 1.0 Frank Richter, 21 December 2023 UG_EN_MUCone.pdf Released © solvimus GmbH...
  • Page 25: Import Of A Device List

    PC and device. Check the physical network connection between the device and the PC, if the cable is correctly joined and inserted. Frank Richter, 21 December 2023 Version: 1.0 Page 25/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 26: The Device Can Not Be Accessed Via Website Respectively Ftp(S)

    Clear the cache in the browser and reload the website (e. g. key F5 respectively CTRL+F5 ). If errors could not be eliminated, please contact our customer support: E-Mail: support@solvimus.de Phone: +49 3677 7613065 Page 26/88 Version: 1.0 Frank Richter, 21 December 2023 UG_EN_MUCone.pdf Released © solvimus GmbH...
  • Page 27: Web-Based Front End

    4 Web-based front end 4.1 General information Many products from solvimus GmbH, especially data concentrators and gateways for smart metering, are com- ing with an integrated web server and provide a website for the configuration. The devices can be configured easily and in a user-friendly manner via this website.
  • Page 28: Tab General

    Details are given in Section 4.11. The solvimus GmbH provides a manual in PDF format on the homepage. The link can be accessed by clicking the button Help (see Figure 16, bottom right).
  • Page 29: Tab Meter

    The Meter tab displays an overview of the connected meters. It offers further possibilities to the user: searching meters automatically, adding meters manually and configuring meters that are already present. Figure 17: Tab Meter Frank Richter, 21 December 2023 Version: 1.0 Page 29/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 30 Scan button can be used to start an M-Bus scan. The scan mode M-Bus mode is configured in the Configuration tab. More information on this can be found in Section 4.4. Page 30/88 Version: 1.0 Frank Richter, 21 December 2023 UG_EN_MUCone.pdf Released © solvimus GmbH...
  • Page 31: Tab Configuration

    Saving a meter configuration creates a new internal database file for logging the meter values aligned to this updated configuration. 4.4 Tab Configuration The Configuration tab allows the parametrization of the meter interfaces of the device. Frank Richter, 21 December 2023 Version: 1.0 Page 31/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 32 Readout time (local) Readout time for daily to annual specification of the standard readout cycle Continued on next page Page 32/88 Version: 1.0 Frank Richter, 21 December 2023 UG_EN_MUCone.pdf Released © solvimus GmbH...
  • Page 33 Network port of the transparent M-Bus mode Specific parameters of the wM-Bus* wM-Bus frequency Frequency band for the communication with the wM-Bus meters Continued on next page Frank Richter, 21 December 2023 Version: 1.0 Page 33/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 34: Tab Wan

    The WAN tab allows the parametrization of the WAN connection for devices with integrated cellular modem. This is permanently set up when the device is restarted and is kept permanently active. Figure 19: Tab WAN The following parameters are available: Page 34/88 Version: 1.0 Frank Richter, 21 December 2023 UG_EN_MUCone.pdf Released © solvimus GmbH...
  • Page 35 Changing the WAN configuration via an active cellular network connection is not recommended, as the device may no longer be accessible after a changed or invalid configuration. Frank Richter, 21 December 2023 Version: 1.0 Page 35/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 36: Tab Server

    CA certificate for the server must be saved on the device. This is achieved by Config Import of the certificates in PEM format in the tab Service. Page 36/88 Version: 1.0 Frank Richter, 21 December 2023 UG_EN_MUCone.pdf Released © solvimus GmbH...
  • Page 37: Tab Security

    The device is automatically reinitialized by accepting the parameters via the Save button. An existing WAN connection is terminated and re-established. 4.8 Tab User The User tab allows the parametrization of different users and their permissions for the website. Frank Richter, 21 December 2023 Version: 1.0 Page 37/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 38 The user configuration can be changed with the buttons at the bottom or via the context menu. Except from the admin user, other users can be created, deleted or changed. Page 38/88 Version: 1.0 Frank Richter, 21 December 2023 UG_EN_MUCone.pdf Released © solvimus GmbH...
  • Page 39: Tab Log

    Change password button when the admin user is logged in. If the administrator password is lost, the device can only be reset to factory defaults by solvimus GmbH as file access on the device is limited for safety reasons. When resetting, all configuration data and meter data are lost.
  • Page 40: Tab Service

    This download may take some time depending on the size of the log. 4.10 Tab Service The Service tab allows maintenance and provides related information or functions: Page 40/88 Version: 1.0 Frank Richter, 21 December 2023 UG_EN_MUCone.pdf Released © solvimus GmbH...
  • Page 41 Usually these should not be transferred to other devices. Frank Richter, 21 December 2023 Version: 1.0 Page 41/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 42: Print Page

    Using the Update firmware button opens a file selection dialogue as well. An update file can be selected here. The solvimus GmbH provides updates as *. enc files on a regular basis. These files can then be uploaded to the device. After successfully uploading them, the update process is started automatically and the device is then restarted.
  • Page 43: Troubleshooting The Front End

    Please check whether the device is listed in the Netdiscover tool (see Chapter 3). Please check the connectivity in general via a ping test integrated in the Netdiscover tool. Frank Richter, 21 December 2023 Version: 1.0 Page 43/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 44: Login To Website Is Refused

    Please check the user’s permissions in the User tab. If errors could not be eliminated, please contact our customer support: E-Mail: support@solvimus.de Phone: +49 3677 7613065 Page 44/88 Version: 1.0 Frank Richter, 21 December 2023 UG_EN_MUCone.pdf Released © solvimus GmbH...
  • Page 45: Reading Meters Via M-Bus

    The M-Bus follows the principle of request-response, i. e. the master initiates the communication by a re- quest/command which is then answered/confirmed by the slave. Spontaneous data transmission on the part of the slaves is not allowed. Frank Richter, 21 December 2023 Version: 1.0 Page 45/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 46: Configuration Of The Interface On The Web-Based Front End

    The Transparent modes allow the access to the physics of the M-Bus interface via a TCP or UDP port. The data stream is forwarded from the M-Bus interface to an IP interface (network (LAN) or cellular radio (WAN)). Page 46/88 Version: 1.0 Frank Richter, 21 December 2023 UG_EN_MUCone.pdf Released © solvimus GmbH...
  • Page 47: Addressing, Scanning And Scan Range

    Collisions do not occur, and more than 250 meters can be addressed on one bus system. In addition, commissioning is faster because not every meter has to be configured to a unique primary address. Frank Richter, 21 December 2023 Version: 1.0 Page 47/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 48: M-Bus Baud Rate

    The parameter M-Bus baud rate in the Configuration tab is used to configure the bit presentation on the M-Bus interface. The baud rate essentially determines the speed of the data transmission. Page 48/88 Version: 1.0 Frank Richter, 21 December 2023 UG_EN_MUCone.pdf Released © solvimus GmbH...
  • Page 49: M-Bus Timeouts

    In addition, the parameter M-Bus request mode in the Configuration tab can be used to explicitly define the requested data before the actual readout. Devices from solvimus GmbH can send a so-called global readout request to the meter before the actual request. A SND_UD is sent to the meter for this purpose. The user data then consists of only one or two characters.
  • Page 50: M-Bus Multipaging

    The FCB mechanism according to IEC 60870-5-2 is used by the readout sequence. The solvimus GmbH calls this process „multipaging“. In order to request possibly existing telegrams from the meter, the master has to toggle the FCB with each new request REQ_UD2.
  • Page 51: M-Bus Meters Are Not Found

    8-digit serial number is searched for during the scan. It can be extened to the manufacturer, medium and version of the meter using other values for MBUS_SELECTMASK. Frank Richter, 21 December 2023 Version: 1.0 Page 51/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 52: M-Bus Meters Are Found, But Do Not Show Any Data

    (e. g. Primary start address, Secondary address mask). If necessary, split the M-bus into physical parts and scan the sections one after another. If errors could not be eliminated, please contact our customer support: Email: support@solvimus.de Phone: +49 3677 7613065 Page 52/88 Version: 1.0 Frank Richter, 21 December 2023 UG_EN_MUCone.pdf Released © solvimus GmbH...
  • Page 53: Reading Meters Via Wm-Bus

    The other side hase then to respond within this very short time to keep the receiver active, otherwise it will be switched off again. The devices of solvimus GmbH are intended for unidirectional operation and are therefore only used to receive meter data.
  • Page 54: Configuration Of The Interface On The Web-Based Front End

    If errors could not be eliminated, please contact our customer support: Email: support@solvimus.de Phone: +49 3677 7613065 Page 54/88 Version: 1.0 Frank Richter, 21 December 2023 UG_EN_MUCone.pdf Released © solvimus GmbH...
  • Page 55: Wm-Bus Meters Are Found, But Do Not Show Any Data

    (column Encryption key , see Section 4.3). If errors could not be eliminated, please contact our customer support: Email: support@solvimus.de Phone: +49 3677 7613065 Frank Richter, 21 December 2023 Version: 1.0 Page 55/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 56: Reporting Of Metering Data

    Using the client-server model, in the case of data push the device from solvimus GmbH is the client and the third-party system is the server. In the case of the data pull, the device from solvimus GmbH is the server and the third-party system is the client.
  • Page 57: Xml Format

    The following table illustrates the protocol version: Entry Attribute XML-8 interface MESSAGE_TYPE MUC_ID VERSION TIMESTAMP meter INTERFACE Numerisch METER_ID USER MED_ID data OBIS_ID Rohdaten DESCRIPTION MEDIUM UNIT Continued from previous page Frank Richter, 21 December 2023 Version: 1.0 Page 57/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 58: Csv Format

    Several CSV formats are available for transmission of raw frames. CSV is a table-like file format which uses a character, solvimus GmbH uses a semicolon „;“ (in CSV-10 a comma), for separating numerical values and texts (columns) from each other. This allows easy processing or viewing e. g. in Excel.
  • Page 59: Json Format

    One JSON format is available for the reports. JSON is a compact, serialized data stream for representing structured data. This data is usually readable by both humans and machines and separated by delimiters. Frank Richter, 21 December 2023 Version: 1.0 Page 59/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 60 A sample JSON packet looks like this (line feeds are inserted for better illustration): {"muc":{ "MUC_ID":"6891d0800e62","VERSION":"1","TIMESTAMP":1601297784,"meter":[ {"METER_ID":"00000001","INTERFACE":"MBus","MAN":"SIE","VER":21,"MED":"Electricity", "MED_ID":2,"USER":"metering1","data":[ {"DESCRIPTION":"Energy","UNIT":"kWh","SCALE":0.001,"OBIS_ID":"1-0:1.8.0*255", "USER":"energy3","DIF":"04","VIF":"03","entry":[ {"T_MUC":1601297679,"VAL":"537980"},{"T_MUC":1601297761,"VAL":"537980"}, {"T_MUC":1601297765,"VAL":"537980"},{"T_MUC":1601297770,"VAL":"537980"}]}]}, {"METER_ID":"00094824","INTERFACE":"MBus","MAN":"BEC","VER":32,"MED":"Electricity", "MED_ID":2,"data":[ {"DESCRIPTION":"Energy","UNIT":"kWh","SCALE":0.01,"DIF":"0E","VIF":"84 00","entry":[ {"T_MUC":1601297679,"VAL":"2887897"},{"T_MUC":1601297761,"VAL":"2887897"}, {"T_MUC":1601297765,"VAL":"2887897"},{"T_MUC":1601297770,"VAL":"2887897"}]}, {"DESCRIPTION":"Power","UNIT":"W","SCALE":0.01,"DIF":"04","VIF":"A9 00","entry":[ {"T_MUC":1601297679,"VAL":"382207"},{"T_MUC":1601297761,"VAL":"382207"}, {"T_MUC":1601297765,"VAL":"382207"},{"T_MUC":1601297770,"VAL":"382207"}]}]}]}} Page 60/88 Version: 1.0 Frank Richter, 21 December 2023 UG_EN_MUCone.pdf Released © solvimus GmbH...
  • Page 61: Reporting Data Via Tcp

    Data that is exchanged gets encrypted with the public key of the other participant. The decryption is then performed using the secret private key on the recipient side. Frank Richter, 21 December 2023 Version: 1.0 Page 61/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 62 The devices from solvimus GmbH are using certificates in the PEM format (RFC 7468). In the case of server-side authentication, the device from solvimus GmbH checks if the server is trustworthy. This requires an installed certificate (public key) issued by the certification authority to be relied upon, and who has signed the certificate of the server.
  • Page 63: Reporting Data Via Mqtt

    • Report directory: devices/MUC063C/messages/events • Report user name: SolvimusHub.azure-devices.net/MUC063C/?api-version=2018-06-30 • Report password: SharedAccessSignature sr=SolvimusHub.azure-devices.net%2fdevices%2f MUC063C&sig=rQXaVuN%2bjWqh0vVr9E6ybo7VbMBQ4QQNOidzMtoqI2g%3d&se=1639260907 Figure 34: Sample configuration of a report to the Azure cloud Frank Richter, 21 December 2023 Version: 1.0 Page 63/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 64: Example Aws Cloud

    Report port and Report directory of the respective instance. If errors could not be eliminated, please contact our customer support: Email: support@solvimus.de Phone: +49 3677 7613065 Page 64/88 Version: 1.0 Frank Richter, 21 December 2023 UG_EN_MUCone.pdf Released © solvimus GmbH...
  • Page 65: Retry Of A Readout

    The parameters RETRY_INTERVAL, MIN_SEND_INTERVAL and MAX_BACKLOG in the configuration file chip. ini (see Section 8.3) permit user-specific settings. Frank Richter, 21 December 2023 Version: 1.0 Page 65/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 66: Advanced Configuration Options

    (read, write or execute). In addition to the user root, the devices from solvimus GmbH are coming with the user admin. This user has read and write access to the partitions app and ext and can execute files there. For the operator, admin is the user who can completely configure the device.
  • Page 67 • xsltproc: Executing XSL transformations solcmd command interpreter Due to the system access rights for users, solvimus GmbH adds a command interpreter solcmd. It offers special application functions via the command line. The interpreter can be called with various parameters and thus provides access to the application and allows controlling it.
  • Page 68 IP or host name ters NAME_SERVER2 IP address of the secondary DNS Text, max. 255 charac- Not set server, IP or host name ters Continued on next page Page 68/88 Version: 1.0 Frank Richter, 21 December 2023 UG_EN_MUCone.pdf Released © solvimus GmbH...
  • Page 69 DLDE request with meter serial 0, 1 DISABLE number (=0) respectively wild- card request (=1). In the latter case only 1 meter is permitted. Continued on next page Frank Richter, 21 December 2023 Version: 1.0 Page 69/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 70 300, 600, 1200, 1800, 2400 nication 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400, 460800 MBUS_DATABITS Data bits for the M-Bus commu- 7, 8 nication Continued on next page Page 70/88 Version: 1.0 Frank Richter, 21 December 2023 UG_EN_MUCone.pdf Released © solvimus GmbH...
  • Page 71 3: NKE at 0xFD and NKE at 0xFF before the communication 4: NKE at 0xFD, application re- set at 0xFF and NKE at 0xFF be- fore the communication Continued on next page Frank Richter, 21 December 2023 Version: 1.0 Page 71/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 72: Version

    M-Bus slave communica- tion in the system log MBUSSLV_DEVPATH Linux path for the M-Bus slave in- Text, max. 255 charac- Not set terface ters Continued on next page Page 72/88 Version: 1.0 Frank Richter, 21 December 2023 UG_EN_MUCone.pdf Released © solvimus GmbH...
  • Page 73 SECOND METER_CYCLE Not set TIMESTAMP METER_DELAY Delay for reading of meter data 0-4294967295 according to the configured read- ing cycle (in s) Continued on next page Frank Richter, 21 December 2023 Version: 1.0 Page 73/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 74 9: XON/XOFF when sending and receiving MODBUS_IP Not set MODBUS_ Maximum number of parallel 0-80 MAXCONNECTIONS Modbus TCP connections MODBUS_MODE Serial, TCP, UDP Continued on next page Page 74/88 Version: 1.0 Frank Richter, 21 December 2023 UG_EN_MUCone.pdf Released © solvimus GmbH...
  • Page 75 ENCMODE the passwords in the configuration files: 0: no encryption, 1: encryption without MAC, 2: encryption with MAC MUC_REPORT FATALREBOOTTIMEOUT MUC_REPORT SCRIPTABORTTIMEOUT Continued on next page Frank Richter, 21 December 2023 Version: 1.0 Page 75/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 76 3: as 2 and additional Raw binary communication data and parsed replies WAN_DEVPATH Linux path for the WAN interface Text, max. 255 charac- Not set ters Continued on next page Page 76/88 Version: 1.0 Frank Richter, 21 December 2023 UG_EN_MUCone.pdf Released © solvimus GmbH...
  • Page 77 Not set ters WATCHDOG_IDLE Watchdog timeout for the idle 1-4294967295 state (in s) WATCHDOG_PROCESS Watchdog timeout in the busy 1-4294967295 state (in s) Continued on next page Frank Richter, 21 December 2023 Version: 1.0 Page 77/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 78 WMBUS_SMLENABLE Activation of processing SML pro- 0, 1 tocol data WMBUS_STOPBITS Stop bits for the wM-Bus commu- 1, 2 nication Continued on next page Page 78/88 Version: 1.0 Frank Richter, 21 December 2023 UG_EN_MUCone.pdf Released © solvimus GmbH...
  • Page 79 STARTSTOP parent mode of the wM-Bus in- terface (channel 2) MODBUS_TLSENABLE MODBUS_CA_FILE MODBUS_CERT_FILE MODBUS_KEY_FILE MODBUS_INSECURE MBUS_TRANSPARENT_ TLSENABLE Continued on next page Frank Richter, 21 December 2023 Version: 1.0 Page 79/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 80 MBUSSLVMETER_ TLSENABLE MBUSSLVMETER_CA_ FILE MBUSSLVMETER_CERT_ FILE MBUSSLVMETER_KEY_ FILE MBUSSLVMETER_ INSECURE MBUSSLV2METER_ TLSENABLE MBUSSLV2METER_CA_ FILE MBUSSLV2METER_ CERT_FILE MBUSSLV2METER_KEY_ FILE MBUSSLV2METER_ INSECURE Group [REPORT_x]* Continued on next page Page 80/88 Version: 1.0 Frank Richter, 21 December 2023 UG_EN_MUCone.pdf Released © solvimus GmbH...
  • Page 81 (in sec- onds). See complement under- neath this table. *x denotes the report instance 1-10 Table 26: chip.ini parameters Frank Richter, 21 December 2023 Version: 1.0 Page 81/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 82 Addressing mode 0: secondary, 1: primary meter readoutcycle Specific readout cycle (in s) meter maxvaluecount Limitation of the number of meter val- Continued on next page Page 82/88 Version: 1.0 Frank Richter, 21 December 2023 UG_EN_MUCone.pdf Released © solvimus GmbH...
  • Page 83 The file can be manually uploaded to the device via FTPS (see also Section 3.5). However, it is also possible to import it via the Service tab (see Section 4.10). The file has to be provided as packed *. tar. gz file. Frank Richter, 21 December 2023 Version: 1.0 Page 83/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 84 In the EN 13757-3 standard, media types, measurement types (measurement value descriptions) and units and are predefined. The devices from solvimus GmbH are using it for allowing a uniform data display. The following table contains the predefined values for the medium:...
  • Page 85 Access number Device type Manufacturer Parameter set identification Model / Version Hardware version Metrology (firmware) version Customer location Customer Access code user Continued on next page Frank Richter, 21 December 2023 Version: 1.0 Page 85/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 86 Index Unit Symbol Description None None Binary Local currency units Volt Ampere Watt hour Joule Cubic meter Kilogram Second Continued on next page Page 86/88 Version: 1.0 Frank Richter, 21 December 2023 UG_EN_MUCone.pdf Released © solvimus GmbH...
  • Page 87 US gallon per second US gal/min US gal/min US gallon per minute US gal/h US gal/h US gallon per hour Degree F Degree Fahrenheit 48-255 Reserved Table 30: Units Frank Richter, 21 December 2023 Version: 1.0 Page 87/88 © solvimus GmbH Released UG_EN_MUCone.pdf...
  • Page 88 MUC.one - User manual 9 Accessory The usage of accessories not recommended is at your own risk. It is imperative to mind Section 1.2.5. Page 88/88 Version: 1.0 Frank Richter, 21 December 2023 UG_EN_MUCone.pdf Released © solvimus GmbH...