Introduction This kit makes it easy to interconnect a Neve 51 Series preamp and equaliser module for rack mounting. It also allows you to connect the inputs, outputs and power supply needed to use the unit, reducing the amount of wiring required to a minimum. The power bus system allows you to connect up to 8 modules, i.e.
Kit overview An input interface card for connecting: § A preamp / dynamics module. § Mic and line inputs. § DI input (optional). § LED meter (optional). § Signal meter threshold bus. § Power bus, compressor/gate link. An EQ interface card for connecting: §...
Conventions Component layout Vertical layout of diodes Straps are made using component legs. The Molex KK connector tab is located on the edge of the board. Location Pin 1 of the Molex KK connectors is on the left. Pin 1 of the IDC connectors is marked with a triangle. Wiring IDC connectors Only IDC connectors are supplied with the kit.
Input interface card assembly instructions part 1 R 100R C 47u/63V IDC 10 IDC 16 Molex KK10 Module STRAPS Only for version without DI XLR F socket Pay attention to : The + side of the polarised capacitor (generally the longer leg) IDC 10 connector notch If you plan to use the standard version without DI option and without Vu meter, go directly to page 13 (Input interface card assembly instructions part 2)
Assembly instructions DI input option part 1 1N 4148 R 22R R 100R R8, R11 R 470R R 3K R 10K R 2M2 R2, 3, 4, 5, 7, 10, 13 Pay attention to : Layout of diode D1 Labo ★ K Effects – www.labo-k-effects.com – karim@labo-k-effecs.com...
Assembly instructions DI input option part 2 100n Film C2, 3, 4, 8 2N 3904 2SK 170BL T2, T3 Relay C 100u NP C5, C6 100u 63V Molex KK3 INST Pay attention to : The + side of the polarised capacitor (generally the longer leg) Relay positioning Transistor orientation Labo ★...
Vu assembly nstructions part 1 1N 4148 D2, 3, 4, 5, 6 R 100R R17, R18 R 180R R 1K R 3K3 R 47K RV1 220K Vu Adjust Pay attention to : Diode layout Labo ★ K Effects – www.labo-k-effects.com – karim@labo-k-effecs.com...
Vu assembly nstructions part 3 Red Led 3mm D6, 7, 8 Green Led 3mm D1, 2, 3, 4 Yellow Led 3mm Pay attention to : Polarity of cathode LEDs (flat side) downwards The IDC connector will be located on the other side of the PCB. Labo ★...
Input interface card assembly instructions part 2 XLR F MIC, LINE Component not installed Note : The Jack Sidechain chassis is not installed It is planned to link dynamics from several racks via this connector. An external vumeter driver can be used via the X4 connector. Labo ★...
EQ card assembly instructions part 5 NE5534 IC1, 4, 5, 6 THAT 1646 IC2, IC7 These components are not fitted Pay attention to : Integrated circuit orientation Labo ★ K Effects – www.labo-k-effects.com – karim@labo-k-effecs.com...
Making the connection cables The PSU ribbon connects the 51/V PSU power supply to the Input interface card. This ribbon also carries the dynamics chain loop when several preamps are connected. Once the components have been positioned in the rack, you need to measure the length required to connect the cards and the power supply, then cut a ribbon to the required length.
Linking dynamics 2 jumpers are used to define the position of the module in the chain 2 straps will be placed in JP1 and JP2 facing the position number in the chain To chain 4 Dynamics : Il faut couper les brins 15 et 16 du ruban BUS PSU aux endroits indiqués Labo ★...
Assembling elements For greater clarity, the Input and EQ interfaces are laid out flat on the diagrams. It is of course possible to arrange these cards vertically, in which case the length of the ribbons will have to be adapted accordingly. PSU BUS and Intercard ribbons Instrument input wiring (INST) Wiring of the LED Vu meter...
Settings The vumeter can display the signal in 4 positions depending on the jumper placed in position JP3 Table of VU Select options A=Output (output level after fader) B=Pre Line sense (line input level) C=Post Line sense (line input level after gain trimmer) D=Input stage (input level) Labo ★...
Modification of board 10880 of eq Neve 51 The Patch interface 10882 card on the equalizer module must be removed. A jumper must be fitted between pins 2 & 3 and 1 & 9 of FSP7. Labo ★ K Effects – www.labo-k-effects.com – karim@labo-k-effecs.com...
Verification It is good practice to test the interface cards before connecting the modules. Start by testing the power connections before powering up. Use a beeper to check that the supply voltage rails arrive at the correct points. Start with the Input card alone. The 0V should arrive at pin 10 of the CONN3 Molex connector.
Settings and adjustments To make the following settings, the following conditions must be met. Audio input will be via the LINE input. Set the gain trimmer to 0. Check that the filters, equaliser and Dynamics are not engaged. Apply a sinusoidal signal of frequency 1khz and amplitude 0dBm to the line input of the input module.
List of input interface card components part 1 Standard NAME VALUE VISUAL REFERENCE 100R 47u63V PSU BUS Connecteur IDC 16 Connecteur IDC 10 Conn1 Connecteur KK10 Conn2 Connecteur KK10 Conn3 Connecteur KK10 Conn4 Connecteur KK10 XLR 3 F NC3FAHR2 LINE XLR 3 F NC3FAHR2 DI option...
List of LED board components NAME VALUE VISUAL REFERENCE LED 3mm Green LED 3mm Green LED 3mm Green LED 3mm Green LED 3mm Yellow LED 3mm LED 3mm LED 3mm Conn1 IDC 10 Labo ★ K Effects – www.labo-k-effects.com – karim@labo-k-effecs.com...
List of components of the eq interface card part 2 NAME VALUE VISUAL REFERENCE 1N4148 1N4148 1N4148 1N4148 LINK1 Strap CONN1 MOLEX KK10 CONN2 MOLEX KK10 CONN4 Not fitted MOLEX KK3 Preamp IDC10 Jack TRS NRJ6HF-1 Jack TRS NRJ6HF-1 XLR M Output NC3MAHR NE5534...
Drilling template Legal notice : Labo ★ K Effects declines all liability with regard to direct and indirect damage caused by improper use of the kit by the user. Labo ★ K Effects – www.labo-k-effects.com – karim@labo-k-effecs.com...
Need help?
Do you have a question about the NEVE 51 RACKING KIT and is the answer not in the manual?