XI-MACHINES FM1 Operating Manual

Flexible mediaserver

Advertisement

Quick Links

flexible mediaserver FM1
OPERATING MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for XI-MACHINES FM1

  • Page 1 FM1 OPERATING MANUAL...
  • Page 2 FM1 / Operating Manual / Q2.23...
  • Page 3: Table Of Contents

    Driver Updates Operating System Updates Backup Reset to Factory Defaults Cable Route & Display Adapters Warranty & Support Contacting XI-MACHINES Technical Specifications Noise Emission Test Report Declaration of Conformity (CE) Declaration of Conformity (FCC) FM1 / Operating Manual / Q2.23...
  • Page 4 FM1 / Operating Manual / Q2.23...
  • Page 5: Safety Notes

    ⚠ If any problems occur, turn off the unit first and then unplug it from power. ⚠ Do not attempt to repair the unit yourself: Always consult XI-MACHINES authorized service personnel or your integrator. ⚠ Do not expose this unit to high moisture or spillover liquid of any kind. Should any form of liquid or a foreign object enter the unit, do not use it.
  • Page 7: Introduction

    FM1 is the most compact product of our “flexible mediaserver platform.” This platform represents true flexibility in terms of the software used and the intended area of application. FM1 is always tailored to you, your use case, and your preferred software. This is why our specialists validate FM1 for the use with a variety of professional applications (see “Media Server Software”...
  • Page 8: Overview & Connections

    Air Intake USB 3.1 Type-A Ports Illuminated Power Button Fresh air supply for the FM1. Do not block! Use these to connect USB Type-A devices Press Button once to start your FM1. Push to your FM1.
  • Page 9 Rear View - FM1 IEC Power Connector Air Outlet DisplayPort Connector Use this to connect your FM1 to a power Heated air from inside of the FM1 will Control monitor output to display the source. exhaust from here. Do not block! graphical user interface (GUI).
  • Page 10: Starting-Up

    To start-up your flexible mediaserver FM1, connect your setup to the appropriate ports on the back of the unit and press the power button on the front. The power button will illuminate and your FM1 will start up (See section “Overview and Connections”...
  • Page 11: Pre-Installed Software

    Pre-installed Software In addition to any media server software that may have been pre-installed, every flexible mediaserver FM1 comes with a selection of useful and commonly used applications: • 7zip • Dante Virtual Soundcard (License optional. Talk to our sales team) •...
  • Page 12: Expansion Options

    FM1 will continue to function correctly. Operating System Updates The operating system installation of your flexible mediaserver FM1 has been set to a fixed update status validated by our specialists. To avoid possible errors and malfunctions, we do not recommend to perform operating system updates unless absolutely necessary.
  • Page 13: Backup

    There are a variety of backup software solutions on the market. We do not offer additional backup solutions as a part of our flexible mediaservers. ⚠ We recommend creating additional image backups of the final installation state of your FM1 when ready to be handed over to your client or when being installed in your venue. ⚠...
  • Page 14: Cable Route & Display Adapters

    ⚠ Be sure to always use so-called “active adapters”, as they have active electronic components inside them that actually convert one display standard to another and not just rewire the connectors. | www.flexible-mediaserver.com FM1 / Operating Manual / Q2.23...
  • Page 15: Warranty & Support

    Every flexible mediaserver FM1 is equipped with a remote support module. Should a possible problem not be solved via call or via email, it is possible for our technicians to access your FM1 using our pre-installed Quick Support Module. To do so, navigate to “C:\XI-MACHINES Support\” and start the Quick Support Module. After you have launched it and once you have confirmed the connection, our technicians can connect to your flexible mediaserver FM1 and start debugging.
  • Page 16: Contacting Xi-Machines

    Telephone: +49 40 4666675-30 Email: support@xi-machines.com Sales Department For expansion options or any other upgrades or changes to your flexible mediaserver FM1, please feel free to contact our sales team. Telephone: +49 40 4666675-10 Email: sales@xi-machines.com | www.flexible-mediaserver.com...
  • Page 17 FM1 / Operating Manual / Q2.23 www.flexible-mediaserver.com |...
  • Page 18: Technical Specifications

    Power Supply Industrial PSU (350W, 100-240V AC, 10-6A, 50-60Hz) Power Consumption idle/typical/max 32W / 142W / 149W Heat Dissipation idle/typical/max 109BTU/h / 485BTU/h / 508BTU/h Noise Emission idle/typical/max 43.6dB / 44.7dB / 45.1dB | www.flexible-mediaserver.com FM1 / Operating Manual / Q2.23...
  • Page 19 Your software not included? Talk to us! Software license required Rack handles removable Based on base confi guration - values vary depending on Expansion Options selected Measurements taken in sound lab at distance of 1m / 39.4" FM1 / Operating Manual / Q2.23 www.flexible-mediaserver.com |...
  • Page 20: Noise Emission Test Report

    Measurement Distance: 100cm Tested Device XI-MACHINES fl exible mediaserver FM1 Device Confi guration: FM1 base confi guration (8-Core CPU, 16 GB System Memory, 500GB NVMe System Drive) Expansion Options: Display-Output 4 RT (Nvidia RTX A2000) Test Results Hamburg, 25.01.2022 Device Status Max / LAFmax_dt+k1 45.1 dB...
  • Page 21 Measurement Distance: 100cm Tested Device XI-MACHINES fl exible mediaserver FM1 Device Confi guration: FM1 base confi guration (8-Core CPU, 16 GB System Memory, 500GB NVMe System Drive) Expansion Options: Display-Output 4 RT1 (Nvidia RTX A4000) Test Results Hamburg, 25.01.2022 Device Status Max / LAFmax_dt+k1 44.3 dB...
  • Page 22: Declaration Of Conformity (Ce)

    EN 60950-1:2006+A11:2009+A1:2010+A12:2011+AC:2011+A2:2013 EMC: EN 55024:2010, EN 55032:2016-02 RoHS: EN IEC 63000:2018 27.01.2022 Hamburg, Germany Jan Weber, head of compliance (date of issue) (place of issue) (issued by, position / title) (signature / stamp) | www.flexible-mediaserver.com FM1 / Operating Manual / Q2.23...
  • Page 23: Declaration Of Conformity (Fcc)

    Jan Weber, head of compliance (date of issue) (place of issue) (issued by, position / title) (signature / stamp) Importer (date of issue) (place of issue) (issued by, position / title) (signature / stamp) FM1 / Operating Manual / Q2.23 www.flexible-mediaserver.com |...
  • Page 24 Copyright 2023 XI-MACHINES GmbH. All rights reserved. All brand names and product names are trademarks, registered trademarks or trade names of their respective holders. All technical specifications in this document are subject to change without further notice. XI-MACHINES GmbH • Lokstedter Steindamm 35 • 22529 Hamburg • Germany • +49-40-466 66 75-0 • www.flexible-mediaserver.com...

Table of Contents