Fluid.io FDL400 Mounting And Operating Instructions

Flow data logger

Advertisement

Quick Links

Mounting- and operating instructions
FDL400
Flow Data Logger
Fluid.iO Sensor + Control GmbH & Co. KG
An der Hartbrücke 6
D - 64625 Bensheim
Tel.: +49-6251-8462-0
Fax: +49-6251-8462-72
Web: www.fluidio.de
E-Mail: info@fluidio.de

Advertisement

Table of Contents
loading

Summary of Contents for Fluid.io FDL400

  • Page 1 Mounting- and operating instructions FDL400 Flow Data Logger Fluid.iO Sensor + Control GmbH & Co. KG An der Hartbrücke 6 D - 64625 Bensheim Tel.: +49-6251-8462-0 Fax: +49-6251-8462-72 Web: www.fluidio.de E-Mail: info@fluidio.de...
  • Page 2 BA FDL400 EN Version: EN_230215_ FDL400_TOLI|...
  • Page 3: Table Of Contents

    SD – Card ..........11 Modification and conversion of the device is not  6.3. USB - port ..........11 permitted and releases Fluid.iO Sensor + Control 6.4. Individual channel shapes ......12 GmbH & Co. KG from any warranty and liability 6.5.
  • Page 4: Determination And Proper Use

     service personnel. cover. In this case, please contact Fluid.iO Sensor + Control 2.2. Determination and proper use GmbH & Co. KG. 2.5. Technological progress The manufacturer is not liable for damages resulting from improper use.
  • Page 5: Technical Data

    (depending of outputs - and sensor currents) Fuse: Device protected against polarity reversal In addition to its actual measuring function, the FDL400  Protection class: IP30 measuring device also serves as a power supply unit for ...
  • Page 6: Mounting Instructions

    BA FDL400 EN 3.2. Mounting instructions On delivery, the device is intended for wall mounting. By means of the supplied clamp, the device can be mounted on a standard rail when used in the control cabinet. For this purpose, the 3 screws with the rosettes on the back of the device are loosened.
  • Page 7: Outputs

    BA FDL400 EN 4.2. Outputs 4.3. Sensor In ATEX relevant applications never do operate the sensor without the safety guard via plug! CAUTION Version: EN_230215_ FDL400_TOLI|...
  • Page 8: Connection Diagram

    BA FDL400 EN 4.4. Connection diagram 5.1. Function keys Button „B” Break (Interrupting the measuring program for inputting parameters) Button „E“ Enter Button „F“ Correction Button „A“ Cancel Button „C“ No function Button „D“ Data transfer - starts the output of the measurement data to the USB interface.
  • Page 9 BA FDL400 EN ", a changeover "pos" or "neg" is Function 12 Set date and time (correct) provided with the help of the (This function is important for button "F". The value entered the correct time and date under Function 4 (V or H - assignment of stored data).
  • Page 10 BA FDL400 EN be performed before updating the firmware. All three functions (90, 91 and 92) Reading back the SYSTEM.CFG Function 51 set the currently measured input system configuration from the value as zero for the selected SD card to the internal memory.
  • Page 11: Further Functions

    BA FDL400 EN 6. Special features Füllhöhe 6.1. Display Tatsächliche Fließgeschwindigkeit At the moment of keyboard operation, the display illumination turns on automatically. During device operation, the display is then illuminated so that pleasant operation is possible. The display illumination Fließgeschwindigkeit...
  • Page 12: Individual Channel Shapes

    BA FDL400 EN 6.4. Individual channel shapes 6.6. Reading & processing data In the device software, four types of channels can be To read out data, the SD card must be removed from the preselected under "Function 1" (circle, rectangle, device and inserted into the appropriate card slot of a trapezoid and V-shape).
  • Page 13: Declaration Of Conformity

    BA FDL400 EN 7. Declaration of Conformity Version: EN_230215_ FDL400_TOLI|...
  • Page 14: Type Examination Certificate (Atex)

    BA FDL400 EN 8. Type Examination Certificate (ATEX) Version: EN_230215_ FDL400_TOLI|...
  • Page 15 BA FDL400 EN Version: EN_230215_ FDL400_TOLI|...
  • Page 16 BA FDL400 EN Version: EN_230215_ FDL400_TOLI|...