Clinton IB-A Instruction Manual

Clinton IB-A Instruction Manual

Industrial bus communication module

Advertisement

Quick Links

Model IB-A Industrial Bus Communication Module
Instruction Manual
Clinton Instrument Company
295 East Main Street
Clinton, CT 06413 USA
Telephone: 860.669.7548 Fax: 860.669.3825
www.clintoninstrument.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IB-A and is the answer not in the manual?

Questions and answers

Summary of Contents for Clinton IB-A

  • Page 1 Model IB-A Industrial Bus Communication Module Instruction Manual Clinton Instrument Company 295 East Main Street Clinton, CT 06413 USA Telephone: 860.669.7548 Fax: 860.669.3825 www.clintoninstrument.com...
  • Page 2 Model IB-A Industrial Bus Communication Module Rev Null b0004 9/19/2022 IB-A Instruction Manual – Page 1...
  • Page 3: Table Of Contents

    INSTALLATION ....................................6 CAUTION: ....................................... 6 ....................................... 6 NPACKING ......................................7 NSTALLATION Mounting the IB-A to an A Series Spark Tester ..........................7 Din-Rail Mounting ..................................... 7 ......................................7 OWER IRING Install an external disconnecting device ............................7 Mains Power...................................... 7 ™...
  • Page 4: Specifications

    Model IB-A Industrial Bus Communication Module Specifications IB-A Instruction Manual – Page 3...
  • Page 5 Model IB-A Industrial Bus Communication Module IB-A Instruction Manual – Page 4...
  • Page 6: Safety

    Indicates Hot Surface. Do not touch. Risk of electric shock symbol. Earth ground symbol. Environmental Conditions The IB-A is designed to be safe under the following conditions: • Indoor use. • Altitude to 2000m. • Temperatures from 5ºC to 40ºC.
  • Page 7: Installation

    The following items are packed with the spark tester: 1. IB-A Industrial Bus Communication Module 2. AnyBus Field bus Module (May be installed in IB-A) 3. A power cord 4. RS-485 connecting cable...
  • Page 8: Installation

    Mounting the IB-A to an A Series Spark Tester Decide which side of the spark tester you wish to mount the IB-A. Note that you may have to remove the small plate from the IB-A chassis and secure it to the opposite side so that the connections are accessible from the spark tester back panel.
  • Page 9: Installing The Compactcom™ Module

    Ethernet IP, Modbus RTU, Modbus TCP, Profibus, Profinet) To enable the Fieldbus Interface the proper CompactCom™ module will need to be installed into the IB-A. • First remove the Anybus Slot Cover from the rear of the IB-A. • Remove the CompactCom™ module from the packaging. •...
  • Page 10: Definition Of Terms

    Model IB-A Industrial Bus Communication Module Definition of Terms Actual Voltage- Actual voltage is a metering winding on the high voltage transformer. This winding can be monitored remotely and indicates the level of voltage supplied to the electrode. Any Fault Alarm- This alarm will respond when a fault of any type is detected. This alarm can be latched, and when latched the voltage can be removed or left on.
  • Page 11: Fieldbus Communications Interface

    Model IB-A Industrial Bus Communication Module Fieldbus Communications Interface The model HF-15B can be purchased with an optional Fieldbus Communications Interface. (Model HF-15BX) This interface will allow the installation of several communication options. (DeviceNet, Ethernet IP, Modbus RTU, Modbus TCP, Profibus, Profinet).
  • Page 12: Fieldbus Spark Tester Parameter Addresses

    Model IB-A Industrial Bus Communication Module Fieldbus Spark Tester Parameter Addresses The fieldbus parameters are 2 bytes each. The LSB will be at the lower byte offset, the MSB at the higher byte offset. As an example, the setpoint is 5000 volts (1388H in hexadecimal). The setpoint is at a word address 5. When reading the two bytes of the setpoint the LSB (value of 88H) would be received first and the MSB (value of 13H) would be received second.
  • Page 13: Cic Iba Utility

    Model IB-A Industrial Bus Communication Module CIC IBA Utility To configure any of the active CompactCom™ modules (DeviceNet, Ethernet IP, Modbus RTU, Modbus TCP, Profibus, Profinet), plug in a USB B cable and run the CIC IBA Utility. If the USB cable is not connected the CIC IBA Utility will prompt for the USB cable as shown.
  • Page 14 Model IB-A Industrial Bus Communication Module Once edits are complete, press the Finish Button. The following screen will be shown indicating a power cycle is required. Once power has been cycled the new values will be used. IB-A Instruction Manual – Page 13...
  • Page 15: Maintenance

    The IB-A does not appear on network 1. Use the IB-A utility to verify your network settings. Cycle power on the IB-A to save the settings. 2. Verify the PLC or PC control system has the Input and Output map sizes of 32 individual words each.
  • Page 16: Replacement Parts

    Assembly PCB Communication Module Note: Printed circuit boards are carefully constructed and calibrated at the factory. Components are not supplied for field repair of boards. Please return faulty circuit boards to the factory or to your Clinton sales representative for evaluation.
  • Page 17: Warranty

    Warranty The information contained in this document is subject to change without notice. The Clinton Instrument Company makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties or merchantability and fitness for a particular purpose.
  • Page 18: Grounding Of Conductors During The Spark Test

    Model IB-A Industrial Bus Communication Module Grounding of Conductors during the spark test IB-A Instruction Manual – Page 17...
  • Page 19 Model IB-A Industrial Bus Communication Module IB-A Instruction Manual – Page 18...

Table of Contents