Microsonic lcs-25/DDD/QP Operating Manual

Ultrasonic sensor with three switching outputs

Advertisement

Quick Links

Product Description
Ԏ
The lcs-sensor offers a non-contact
measurement of the distance to an
object which must be positioned
within the sensor's detection zone.
The switching outputs are set con-
ditional upon the adjusted detect
distances.
Ԏ
The output functions are adjustable
from NOC to NCC.
Ԏ
Three-colour LEDs indicate the swit-
ching status.
Ԏ
The sensor can be set via Teach-in
procedure.
Ԏ
Optionally all Teach-in and additio-
Operating Manual
nal sensor parameter settings can be
Ultrasonic sensor
made using the LinkControl adapter
with three switching outputs
(optional accessory) and the Link-
Control software for Windows
lcs-25/DDD/QP
lcs-35/DDD/QP
lcs-130/DDD/QP
Diagram 1:  Download of sensor parameters in the LCA-1
Press
F + T2
at the LCA-2 simultaneously for about 1 s.
F + T2
Press
R
at the LCA-2 for about 1 s.
R
Parameters are transfered from the sensor to the LCA-2.
Download of parameters completed.
Current measurement value is displayed.
Safety Notes
Ԏ
Read the operating manual prior
to start-up.
Ԏ
Connection, installation and ad-
justment works should be carried
out by expert personnel only.
Ԏ
No safety component in ac-
cordance with the EU Machine
Directive, use in the area of per-
sonal and machine protection
not permitted
Proper Use
lcs ultrasonic sensors are used for non-
contact detection of objects.
The lcs-sensors have a blind zone in
which distance measurement is not
possible. The operating range indi-
cates the distance of the sensor that
.
®
can be applied with normal reflectors
with sufficient function reserve. When
using good reflectors, such as a calm
water surface, the sensor can also be
used up to its maximum range. Ob-
jects that strongly absorb (e.g. plastic
foam) or diffusely reflect sound (e.g.
pebble stones) can also reduce the
defined operating range.
Diagram 2:  Upload of sensor parameters back to the sensor
Press
F + T1
at the LCA-2 simultaneously for about 1 s.
F + T1
Press
R
at the LCA-2 for about 1 s.
R
Parameters are transfered from the LCA-2 to the sensor.
Upload of parameters completed.
Current measurement value is displayed.
Installation
Start-Up
Mount the sensor at the place of
Connect the power supply.
Î
Î
fitting.
Set the sensor parameters using the
Î
Connect a connection cable to the
Teach-in procedure, see Diagram 4.
Î
M12 device plug, see Fig. 1.
Factory Setting
lcs-sensors are delivered factory made
2
1
with the following settings:
3x
3
5
4
Ԏ
Switching outputs on NOC
colour
Ԏ
Detect distance at operating range
1
+U
brown
B
and at half operating range
3
–U
blue
B
Ԏ
Measurement range set to maxi-
4
D2
black
2
D1
white
mum range
5
D3/Com
grey
Maintenance
Fig. 1: Pin assignment with view onto sensor
plug and colour coding of the
microsonic sensors are maintenance-
microsonic connection cables
free. In case of excess caked-on dirt
Assembly distances
we recommend to clean the white
The assembly distances shown in
sensor surface.
Fig. 2 for two or more sensors should
not be fallen below in order to avoid
mutual interference.
lcs-25...
>0.10 m
>1.0 m
lcs-35...
>0.30 m
>1.7 m
lcs-130...
>0.60 m
>5.4 m
Fig. 2: Assembly distances
Diagram 3:  Factory setting
Notes
Ԏ
lcs-sensors have internal tempera-
ture compensation. Because the
sensors heat up on their own, the
temperature compensation reaches
its optimum working point after
approx. 30 minutes of operation.
Ԏ
In the normal operating mode, an
illuminated yellow LED signals that
the corresponding switching output
is set.
Ԏ
During Teach-in procedure, the hys-
teresis loops are set back to factory
settings.
Ԏ
If no signal is generated at the Com
input for 20 seconds during the
Teach-in procedure, the settings
made up to that point are stored
and the sensor returns to normal
operating mode.
Ԏ
The sensor can be reset to its facto-
ry setting (see Diagram 3).
Further settings
Reset to factory
setting
Switch off
operating voltage.
Switch on
operating voltage,
while D3/Com is
connected to –U
.
B
Keep D3/Com connected
to –U
about 13 s, until
B
LED D1 and D2
stop flashing .
Normal operating mode

Advertisement

loading
Need help?

Need help?

Do you have a question about the lcs-25/DDD/QP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Microsonic lcs-25/DDD/QP

  • Page 1 Fig. 1: Pin assignment with view onto sensor procedure. settings. contact detection of objects. plug and colour coding of the microsonic sensors are maintenance- Ԏ Optionally all Teach-in and additio- Ԏ If no signal is generated at the Com Operating Manual...
  • Page 2 Diagram 4:  Setting of parameters using the LinkControl Adapter LCA-2 (Offline programming) Start here Press T1 and T2 simultaneously for about 3 s until welcome message has passed. Set switching output D1 Set switching output D2 Set switching output D3 T1 + T2 Set detect distance in mm or cm. T1 + T2 For single switching For window mode...
  • Page 3 With LinkControl the selected filter setting influences the switching frequency and response time. *B7301* microsonic GmbH / Phoenixseestraße 7 / 44263 Dortmund / Germany / T +49 231 975151-0 / F +49 231 975151-51 / E info@microsonic.de / W microsonic.de MV-DO-074381-854345...

This manual is also suitable for:

Lcs-35/ddd/qpLcs-130/ddd/qp