Download Print this page
Chatsworth Products Oberon 1019 Series Installation Manual

Chatsworth Products Oberon 1019 Series Installation Manual

Advertisement

Quick Links

Installation Guide /
Guía de instalación
for Oberon Model 1019-XXXX
para Modelo Oberon 1019-XXXX
Thank you for choosing Oberon.
/ Gracias por elegir Oberon.
Instructions are for typical install conditions. Instructions may not be
correct for all installations due to building design, construction ma-
terials or methods used and/or building or site conditions. Consult a
contractor or architect for recommendations. For product questions
call (+1) 877-867-2312.
Las instrucciones son para condiciones típicas de instalación. Las
instrucciones pueden no ser correctas para todas las instalaciones
según el diseño del edificio, materiales de construcción o métodos
utilizados, o condiciones del edificio o del lugar. Consulte a un con-
tratista o arquitecto para obtener recomendaciones. Si tiene
preguntas con respecto al producto, llame al (+1) 877-867-2312.
WARNING
/ ADVERTENCIA
Follow manufacturer's instructions for hand or power tools.
Always use safety glasses. Failure to do so may result in injury
and/or product damage.
Siga las instrucciones del fabricante para herramientas manu-
ales o eléctricas. Utilice siempre gafas de seguridad. Si no lo
hace, podría producirse lesiones y / o daños al producto.
WARNING
/ ADVERTENCIA
Use caution when working at elevated heights. Follow manu-
facturer's instructions for ladders and/or scaffolding. Failure to
do so may result in injury or death.
Tenga cuidado al trabajar a alturas elevadas y alrededor de las
aberturas de la unidad. Siga las instrucciones del fabricante
para laddors y / o andamios. Si no lo hace, podría causar le-
siones o la muerte.
"Oberon" and all other marks where denoted are trademarks of Oberon Inc.
"Oberon" y todas las demás marcas donde se denotan son marcas comerciales de Oberon Inc. ©1999-2021 Oberon Incorporated. Todos los derechos reserve.
Oberon's Model 1019 Envelope™ enclosures conceal Wi-Fi and
Small Cell APs, Wi-Fi routers, and associated cabling in resi-
dence halls, hotels, multiple dwelling units, retail locations and
other indoor venues. Recess AP into the wall and conceal with
the low profile, paintable, snap-on cover. This rugged UL 94-5VB
ABS plastic enclosure is virtually transparent to wireless signals
so there is minimal impact on wireless coverage. The 1019 fea-
tures slots for TIA 569-B compliant furniture faceplate RJ-45
modular jacks, to facilitate cable termination and management.
Los gabinetes del modelo 1019 Envelope™ de Oberon ocultan
los AP de Wi-Fi y de celda pequeña, los enrutadores de Wi-Fi y
el cableado asociado en residencias estudiantiles, hoteles, uni-
dades de vivienda múltiple, tiendas minoristas y otros espacios
interiores. Coloque el AP en la pared y esconda con la cubierta a
presión de bajo perfil, que se puede pintar. Esta resistente car-
casa de plástico ABS UL 94-5VB es prácticamente transparente
a las señales inalámbricas, por lo que el impacto en la cobertura
inalámbrica es mínimo. El 1019 cuenta con ranuras para en-
chufes modulares RJ-45 de placa frontal para muebles que
cumplen con TIA 569-B, para facilitar la terminación y el manejo
de los cables.
Parts Included
/ Partes Incluidas
1019-RM
(1) Recess Box
/ Caja de recreo
(1) Bezel
/ Bisel
(1) Cover
/ Cubrir
(4) Press Pads
/ Almohadillas de prensa
(1) Spare Press Pad
/ Almohadilla de prensa de repuesto
(6) Cable Organizer Pins
/ Pines del organizador de cables
(1) AP Mounting Plate
/ Placa de montaje AP
(4) M4-0.7 x 6mm Pan Head Machine Screws
/
Tornillos de máquina de cabeza plana M4-0.7 x 6mm
(4) #4-24 x 1/2" Pan Head Thread-Forming Screws for Plastic
Tornillos formadores de rosca de cabeza plana #4-24 x 1/2" para
plástico
(4) #4-24 x 1-1/2" Pan Head Screws
/
Tornillos de cabeza plana #4-24 x 1-1/2"
(4) #8-15 x 1/4" Pan Head Screws
/
Tornillos de cabeza plana #8-15 x 1/4"
1019-SM
(1) Cage (back box) /
(1) Jaula (caja trasera)
(1) Tamper Resistant Snap-on Cover /
(1) Cubierta a presión
resistente a la manipulación
(36) Removable Cable Management Pegs /
(36) Clavijas de
gestión de cables extraíbles
(4) M4 x 25MM Screws /
(4) M4 x 25MM Tornillos
(4) 6MM x 25MM Wall Anchors /
(4) Anclajes de pared de 6MM x
25MM
©1999-2021 Oberon Incorporated. All rights reserved.
EPN 2998, 2999 - Rev. 10/16/2023
Important Information for Model 1019
/ Información importante para el modelo 1019
1. Always consider potential hazards to others around you.
2. During installation, use warning signs, etc.
3. Be sure to securely fasten the enclosure to prevent it from becoming dislodged.
4. AC Power is not to be used inside the enclosure.
5. This product is intended to be installed by trained personnel.
6. Maximum weight to be installed in the unit is 10 lbs.
7 Enclosure must be installed in accordance with requirements of Local Building Codes, Canadian Electrical Code (CEC), CAN/CSA C22.1
and National Electric Code (NEC), NFPA 70. An appropriate disconnect device shall be provided as part of building installation.
1. Considere siempre el peligro potencial para quienes lo rodean.
2. Durante la instalación, utilice las señales de advertencia y demás señales.
3. Asegúrese de sujetar firmemente el gabinete para evitar que se desprenda.
4. La energía de CA no se debe utilizar dentro del gabinete.
5. Este producto está diseñado para ser instalado por personal capacitado.
6. El peso máximo que se debe instalar en la unidad es de 10 libras.
7. La caja debe instalarse de acuerdo con los requisitos de los códigos de construcción locales, el código eléctrico canadiense (CEC), CAN/
CSA C22.1 y el código eléctrico nacional (NEC), NFPA 70. Se debe proporcionar un dispositivo de desconexión apropiado como parte de la
instalación del edificio.
Table of Contents
/ Tabla de Contenido
Pg.
2—1019-RM
Pg.
4—1019-SM
/
Important code and installation information.
/ Información im-
portante sobre normas e instalación.
Read guide from beginning to end before beginning installation.
Read all warnings and cautions before beginning unit installa-
tion. Check with your local building code official to identify and
confirm compliance with local building code requirements. This
installation guide covers installing your Model 1019 in a typical
environment. The appropriate method for your installation may
vary based on building design, application, and industry practic-
es.
Lea la guía de principio a fin antes de comenzar la instalación.
Lea todas las advertencias y precauciones antes de comenzar la
instalación de la unidad. Verifique con un oficial de código
edilicio de su localidad para identificar y confirmar el cumpli-
miento con los requisitos locales del código de edificación. Esta
guía de instalación cubre la instalación del Modelo 1019 en un
entorno adecuado. El método apropiado para la instalación
puede variar según el diseño del edificio, la aplicación y las
prácticas de la industria.
Tools Needed
/ Herramientas necesarias
- Phillips-Head Screwdriver
/ Destornillador Phillips
- Flat Head Screwdriver
/ Destornillador de cabeza plana
Estimated Installation Time:
15m
Tiempo Estimado de Instalación:

Advertisement

loading

Summary of Contents for Chatsworth Products Oberon 1019 Series

  • Page 1 Installation Guide / Guía de instalación for Oberon Model 1019-XXXX para Modelo Oberon 1019-XXXX Important Information for Model 1019 / Información importante para el modelo 1019 Oberon’s Model 1019 Envelope™ enclosures conceal Wi-Fi and Small Cell APs, Wi-Fi routers, and associated cabling in resi- dence halls, hotels, multiple dwelling units, retail locations and 1.
  • Page 2 Installation Guide / Guía de instalación for Oberon Model 1019-XXXX para Modelo Oberon 1019-XXXX 4a Cont. 4b Cont. 1019-RM (Solo para Cisco AP) Fije la placa de montaje 1019-RM a la caja empo- (Solo para AP de la serie Aruba 5XX) Primero, retire el soporte de metal trada con los cuatro (4) tornillos #8-15 proporcionados.
  • Page 3 Installation Guide / Guía de instalación for Oberon Model 1019-XXXX para Modelo Oberon 1019-XXXX Place the 1019-RM into the wall cutout with the “TOP” side up and tighten the swivel fasteners until they are securely fastened against the wall or ceil- ing.
  • Page 4 Installation Guide / Guía de instalación for Oberon Model 1019-XXXX para Modelo Oberon 1019-XXXX 1019-SM Place the enclosure against the surface to which it will be mounted and mark the hole locations with the keyhole slots. It is recommended that the enclosure be fastened to a stud if possible.