elsner elektronik KNX PS640 Technical Data And Installation Notes

Power supply systems

Advertisement

Quick Links

Power Supply Systems
KNX PS640 and KNX PS640 USB
Item numbers 70140, 70143 (USB)
and Installation Notes
Elsner Elektronik GmbH Control and Automation Engineering
Sohlengrund 16 | 75395 Ostelsheim | Germany
Tel.: +49 (0) 70 33 / 30 945 - 0 | Fax: +49 (0) 70 33 / 30 945 - 20
info@elsner-elektronik.de |
Technical support: +49 (0) 70 33 / 30 945-250
Technical Data
www.elsner-elektronik.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KNX PS640 and is the answer not in the manual?

Questions and answers

Summary of Contents for elsner elektronik KNX PS640

  • Page 1 Power Supply Systems KNX PS640 and KNX PS640 USB Item numbers 70140, 70143 (USB) Technical Data and Installation Notes Elsner Elektronik GmbH Control and Automation Engineering Sohlengrund 16 | 75395 Ostelsheim | Germany Tel.: +49 (0) 70 33 / 30 945 - 0 | Fax: +49 (0) 70 33 / 30 945 - 20 info@elsner-elektronik.de |...
  • Page 2: Technical Data

    Description The Power Supply Systems KNX PS640 and KNX PS640 USB deliver a 29 V bus voltage for the KNX system and 24 V DC supply voltage for 24 V devices. Special operating conditions such as short circuit, overvoltage, overload or excess temperature are recorded and may be read off on the display.
  • Page 3: Installation And Commissioning

    Elsner Elektronik is not liable for any changes in norms and standards which may occur after publication of these operating instructions. Power Supply Systems KNX PS640(USB) | Version: 18.04.2016 | Subject to technical changes. Errors excepted.
  • Page 4: Installation

    Connections 3 and 5 are suitable for solid conductors up to 1.5 mm² or conductors with fine wires. Scheme Auxiliary supply 24 V DC (max. 150 mA) Power Supply Systems KNX PS640(USB) | Version: 18.04.2016 | Subject to technical changes. Errors excepted.
  • Page 5: Operation

    Reset is activated. The line is switched to neutral and shorted. The basic setting displays: “Reset is active!” Reset not activated. The power supply system works in normal operation. Power Supply Systems KNX PS640(USB) | Version: 18.04.2016 | Subject to technical changes. Errors excepted.
  • Page 6: Data Memory

    0 times. Duration: 0 day. 0 hrs. 0 min With key you return to the previous menu level. < = Back Power Supply Systems KNX PS640(USB) | Version: 18.04.2016 | Subject to technical changes. Errors excepted.
  • Page 7: Operating Data

    Move the cursor (flashing rectangle at right edge) to the “Operating Data” menu with the keys and confirm with key Bus Voltage 29.4 V Bus Current 320 mA Temperature 42.1°C Power Supply Systems KNX PS640(USB) | Version: 18.04.2016 | Subject to technical changes. Errors excepted.
  • Page 8 . The display automatically jumps to the previous menu in the desired language. With you get back by one menu level to the basic setting. Power Supply Systems KNX PS640(USB) | Version: 18.04.2016 | Subject to technical changes. Errors excepted.

This manual is also suitable for:

Knx ps640 usb701407014370143 usb

Table of Contents