Check to ensure that all parts are included in the icemaker accessory bag and HS-5061:
KM-81BAJ and KM-116BAJ Accessory Bag
Index
No. Description
1
Inlet Hose
2
Joint Pipe
3
Nylon Tie
For KM-61/101BAH and KM-80/115BAJ, order parts listed in the table above as they are not included in the accessory bag.
HS-5061
Index
No.
Description
1
Drain Pump
2
Vinyl Hose (vent hose) (3/8" ID×27.5")
3
Vinyl Hose (discharge hose) (1/2" ID×10')
4
Small Clamp (vent hose to drain pump)
Items not used from the HS-5061 Kit
Index
Description
No.
1
Vinyl Hose (drain hose) (5/8" ID×4")
2
Vinyl Hose (drain hose) (5/8" ID×5")
3
Vinyl Hose (drain hose) (5/8" ID×6.5")
4
Large Clamp
These instructions are to be used when installing drain pump kit HS-5061.
For additional drain pump warranty, safety, maintenance, and trouble shooting information, refer to the installation manual
provided with the drain pump.
• Only qualified service technicians should install and service the appliance to reduce the risk of death, electric shock,
serious injury, or fire. A plumbing permit and the services of a licensed plumber may be required in some areas.
To obtain the name and phone number of your local Hoshizaki Certified Service Representative, visit
www.hoshizakiamerica.com.
• No installation or service should be undertaken until the technician has thoroughly read these instructions. Failure to install,
operate, and maintain this drain pump in accordance with these instructions will adversely affect safety, performance,
component life, and warranty coverage and may result in costly water damage.
• Proper installation is the responsibility of the installer. Product failure or property damage due to improper installation is not
covered under warranty.
• See the instruction manual provided with the icemaker for icemaker installation. Failure to install the icemaker within these
guidelines may adversely affect safety, performance, component life, and warranty coverage.
• THE ICEMAKER MUST BE GROUNDED: The icemaker is equipped with a 3-prong grounding plug to reduce the risk
of potential shock hazards. It must be plugged into a properly grounded, independent 3-prong wall outlet. If the outlet
is a 2-prong outlet, it is your personal responsibility to have a qualified electrician replace it with a properly grounded,
independent 3-prong wall outlet. Do not remove the ground prong from the power cord and do not use an adapter plug.
• The icemaker and this kit must be installed in accordance with applicable national, state, and local codes and regulations.
• Protect the floor when moving the appliance to prevent damage to the floor.
• This drain pump is approved for use only with the models listed.
• CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after installation.
Make sure that none have fallen into the ice storage bin.
Undercounter Drain Pump
For Use with the Following Hoshizaki Icemaker Series:
KM-61/101/BAH and KM-80/81/115/116BAJ
Part Number Qty.
472482R01
1
472483P01
1
8911-0200
5
Index
Qty.
No.
Description
1
5
Medium Clamp (discharge hose to drain pump)
1
6
Hose Clips (vent hose)
1
7
Truss Head Screw (4×8, SS)
1
Qty.
1
1
1
2
WARNING
1
Qty.
1
2
2
2A9326-012
Need help?
Do you have a question about the HS-5061 and is the answer not in the manual?
Questions and answers