Hoshizaki HS-5061 Installation Instructions Manual
Hoshizaki HS-5061 Installation Instructions Manual

Hoshizaki HS-5061 Installation Instructions Manual

Undercounter drain pump for use with the following hoshizaki icemaker series: km-61/101/bah and km-80/81/115/116baj

Advertisement

Check to ensure that all parts are included in the icemaker accessory bag and HS-5061:
KM-81BAJ and KM-116BAJ Accessory Bag
Index
No. Description
1
Inlet Hose
2
Joint Pipe
3
Nylon Tie
For KM-61/101BAH and KM-80/115BAJ, order parts listed in the table above as they are not included in the accessory bag.
HS-5061
Index
No.
Description
1
Drain Pump
2
Vinyl Hose (vent hose) (3/8" ID×27.5")
3
Vinyl Hose (discharge hose) (1/2" ID×10')
4
Small Clamp (vent hose to drain pump)
Items not used from the HS-5061 Kit
Index
Description
No.
1
Vinyl Hose (drain hose) (5/8" ID×4")
2
Vinyl Hose (drain hose) (5/8" ID×5")
3
Vinyl Hose (drain hose) (5/8" ID×6.5")
4
Large Clamp
These instructions are to be used when installing drain pump kit HS-5061.
For additional drain pump warranty, safety, maintenance, and trouble shooting information, refer to the installation manual
provided with the drain pump.
• Only qualified service technicians should install and service the appliance to reduce the risk of death, electric shock,
serious injury, or fire. A plumbing permit and the services of a licensed plumber may be required in some areas.
To obtain the name and phone number of your local Hoshizaki Certified Service Representative, visit
www.hoshizakiamerica.com.
• No installation or service should be undertaken until the technician has thoroughly read these instructions. Failure to install,
operate, and maintain this drain pump in accordance with these instructions will adversely affect safety, performance,
component life, and warranty coverage and may result in costly water damage.
• Proper installation is the responsibility of the installer. Product failure or property damage due to improper installation is not
covered under warranty.
• See the instruction manual provided with the icemaker for icemaker installation. Failure to install the icemaker within these
guidelines may adversely affect safety, performance, component life, and warranty coverage.
• THE ICEMAKER MUST BE GROUNDED: The icemaker is equipped with a 3-prong grounding plug to reduce the risk
of potential shock hazards. It must be plugged into a properly grounded, independent 3-prong wall outlet. If the outlet
is a 2-prong outlet, it is your personal responsibility to have a qualified electrician replace it with a properly grounded,
independent 3-prong wall outlet. Do not remove the ground prong from the power cord and do not use an adapter plug.
• The icemaker and this kit must be installed in accordance with applicable national, state, and local codes and regulations.
• Protect the floor when moving the appliance to prevent damage to the floor.
• This drain pump is approved for use only with the models listed.
• CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after installation.
Make sure that none have fallen into the ice storage bin.
Undercounter Drain Pump
For Use with the Following Hoshizaki Icemaker Series:
KM-61/101/BAH and KM-80/81/115/116BAJ
Part Number Qty.
472482R01
1
472483P01
1
8911-0200
5
Index
Qty.
No.
Description
1
5
Medium Clamp (discharge hose to drain pump)
1
6
Hose Clips (vent hose)
1
7
Truss Head Screw (4×8, SS)
1
Qty.
1
1
1
2
WARNING
1
Qty.
1
2
2
2A9326-012

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HS-5061 and is the answer not in the manual?

Questions and answers

robert roper
May 20, 2025

how much head pressure?

Subscribe to Our Youtube Channel

Summary of Contents for Hoshizaki HS-5061

  • Page 1 Undercounter Drain Pump For Use with the Following Hoshizaki Icemaker Series: KM-61/101/BAH and KM-80/81/115/116BAJ Check to ensure that all parts are included in the icemaker accessory bag and HS-5061: KM-81BAJ and KM-116BAJ Accessory Bag Index No. Description Part Number Qty.
  • Page 2 Use a screwdriver to push the tab hooking the front panel and remove the front panel (see figs. 1 and 2). Figure 1 Figure 2 nstallation Instructions 1) Remove the front louver, then move the control switch to the "OFF" position. See Fig. 1. If plugged into an electrical outlet, unplug the icemaker from the electrical outlet.
  • Page 3 ee figs. 1 and 2). Route the discharge tube and vent tube through Connect the hoses to the drain pump. 5) Route the discharge hose and vent hose through the drain outlet fitting hole. See Fig. 5. the hole where the drain outlet was located the vent tube and discharge tube with tubing clamps.
  • Page 4 10) Locate the icemaker drain pump connector (inside the plastic bag behind the pipe cover). Remove the icemaker drain pump connector from the plastic bag and remove and discard the jumper plug. Next, connect the drain pump connector to the icemaker's drain pump connector. See Fig. 9. 11) Place the icemaker drain pump connector in the plastic bag and secure with a nylon tie, then replace the connector in its correct position.
  • Page 5: Final Check List

    15) Make sure the icemaker control switch is in the "OFF" position. Plug the icemaker into the electrical outlet. WARNING! To reduce the risk of electric shock, do not touch the control switch or power supply cord plug with damp hands. 16) Slowly pour 24 to 30 oz.
  • Page 6: Maintenance

    Note: If the drain pump fails, water will remain in the drain pump and the appliance if installed properly. Warranty This optional Hoshizaki drain pump carries a one year parts and labor warranty. The warranty begins on the installation date of the drain pump. For warranty validation, be sure to properly register your icemaker.
  • Page 7 HS-5061 Wiring Diagram Wire Color Code BK-BLACK DBU-DARK BLUE GR-GREEN R-RED W-WHITE Voltage Code GND-GROUND N-NEUTRAL 2A9326-012...