Troubleshooting
NO DATA
There is no Master unit inserted in Master pocket (
insert your Master unit in Master pocket (
Charging indicator (
) continuously flashes in red.
3
Non-rechargeable batteries are inserted in units. Replace batteries.
No ba�eries are inserted in units. Insert compa�ble ba�eries.
Batteries inside are potentially defective. Change your batteries.
) con�nuously flashes in red.
3
The charging contacts between units and the charger are not connected. Take units out and
replace them in the charger again.
Potential incompatible channel configura�on between units and the charger. Ensure
channel configura�on on units and the charger are same.
Data-copy indicator (
) continuously flashes in red.
3
The charging contacts between units and the charger are not connected. Take units out and
replace them in the charger again.
Transmitters and receivers are mixed and incorrectly inserted in the charger. Make sure all units
in the chargers are of same model (only transmi�ers or only receivers)
. Potential defects on unit(s). Contact your dealer or Contacta Technical Support.
Specifications
Charging pockets
24
Charging current
350 ± 50 mA, per pocket
Charging time
4 ~ 6 hours @ 2,100 mAh Ni-MH rechargeable ba�eries
Charging algorithm
PWM control, -ΔV and TIMER power-off detector
Power requirements
AC 100 ~ 240 V switching power adapter DC 12 V, 5 A
0
C ~ 40
C (32
Ambient temperature
o
o
Dimensions (D x W x H)
Charger Case:437 x 266 x 170 mm/17.21 x 10.47 x 6.7 in
Charger Unit with Charger Case: 4.69 kgs/10.34 lbs
Weight
Specifications are subject to change without prior no�ce.
Version :9552-028-D2-0124
) when
is under process. Please
6
DATA COPY
).
6
F - 104
F)
o
o
4
User Manual
Illustra�on
1
2
3
1
Detachable suitcase
Slide left to detach the top case
Accessory storage
2
Charging / Channel-Sync / Data-Copy indicator:
3
Steady red: Charging
Steady green: Fully charged
Flashing blue: In the process of channel-sync or data-copy
Flashing red: Potential errors happen (see details in the paragraph of Troubleshoo�ng)
4
DC input
To connect with supplied switching power adapter (DC 12 V, 5 A)
5
Power switch
6
Master pocket
Master unit is inserted here for charging, channel-sync and data-copy
Before channel-sync, make sure both charger and all units share same channel configura�on.
7
Standby indicator of Master pocket
Steady blue: The pocket row is ready for charging, channel-sync and data-copy
Steady red: Master pocket (
) is at DATA COPY mode
6
No LED: The pocket row is potentially defective
8
Slave pockets
Slave units are inserted for charging, channel-sync and data-copy
9
Standby indicator of Slave pockets
Steady blue: The pocket row is ready for charging, channel-sync and data-copy
No LED: The pocket row is potentially defective
Handheld microphone charging port
10
This port is additionally used for charging handheld microphone via supplied programming /
charging cable (
11
). Only charge RF-TXHH using YSB port if RF-TXHH has rechargeable ba�eries
inserted (not provided).
Proprietary software pack (programming / charging cable incl.)
11
RF-DC-24 (24-SLOT CHARGER)
4
5
01
6
7
8
9
10
1
11
10/23
Need help?
Do you have a question about the RF-DC-24 and is the answer not in the manual?
Questions and answers