General; Description Measuring Principle; Drawings, Shortcut - promesstec NVG 200 User Manual

Level device
Table of Contents

Advertisement

Level device NVG 200

1. General

1.1 Description measuring principle

The NVG 200 level device is used for conductive level monitoring in electrically con-
ductive liquids. A simple level control can be implemented on channel 1 using a min.
and max. electrode. A pump or valve can be controlled directly via a potential-free
changeover contact. A switching time delay of 0.5 to 10 seconds can be set. Chan-
nel 2 works independently of the first and can be used either as an additional full or
empty detector. For example, overfill protection or dry-running protection can be
implemented.
- Compact design (top-hat rail mounting, 22.5mm width)
- 2 separate functional channels
- 2 potential-free changers
- Adjustable sensitivity range (1...100 k)
- Adjustable switching time delay (0.5...10 sec)
- Direct voltage-free electrode voltage

1.2 Drawings, shortcut

Warning!
A non-observance can cause injuries to persons and/or the demoli-
tion of the device. There can be a dangerous to life.
Attention!
A non-observance can cause a faulty operation of the device or lead
to property damage.
Information!
A non-observance can have influence on the operation of the device
or cause unintentional reactions of the device.
Danger!
When not observing the safety instructions, there is a risk of serious
or fatal injuries caused by electrical power.
Warning!
Possibly a dangerous situation can occur, which results in burns be-
cause of hot surfaces or liquids, if not avoided.
promesstec GmbH I Niedersachsenstraße 4 I D-48465 Schüttorf I Tel.:+49 (0)5923/ 90 229 0 I Fax:+49 (0)5923/ 90 229 29
E-Mail: office@promesstec.com I Internet: www.promesstec.com