Page 1
Pulse Distributor: IV20 _General functional description _Basic safety instructions _Technical Data _Mounting _Installation _Commissioning User Manual...
Page 2
D-78647 Trossingen Eglishalde 6 Tel.: (0049) 07425/228-0 Fax: (0049) 07425/228-33 email: info@tr-electronic.de www.tr-electronic.com Copyright protection This Manual, including the illustrations contained therein, is subject to copyright protection. Use of this Manual by third parties in contravention of copyright regulations is not permitted. Reproduction, translation as well as electronic and photographic archiving and modification require the written content of the manufacturer.
7.1.3 Operating Mode 3, 11…30 V Open-Collector (single-phase) ......... 19 7.1.4 Operating Mode 4, 11…30 V Open-Emitter (single-phase) ........19 7.2 Setting the output level ......................20 TR-Electronic GmbH 1998, All Rights Reserved Printed in the Federal Republic of Germany 02/27/2024...
Revision index Revision index Revision Date Index First release 17.04.1998 General overhaul 02/27/2024 TR Electronic GmbH 1998, All Rights Reserved Printed in the Federal Republic of Germany Page 4 of 20 TR-ECE-BA-GB-0057 v03 02/27/2024...
A corresponding declaration of conformity can be requested from TR Electronic GmbH. The manufacturer of the product, TR Electronic GmbH in D-78647 Trossingen, operates a certified quality assurance system in accordance with ISO 9001. TR-Electronic GmbH 1998, All Rights Reserved Printed in the Federal Republic of Germany 02/27/2024...
Association for Electrical, Electronic & Information Technologies 1.4 General functional description The IV20 pulse distributor is used in conjunction with an incremental encoder to extend the signal path in complex systems. The device enables the distribution of the signals K1, /K1 and K2, /K2 as well as K0, /K0 of a single encoder to six outputs, each with different output potentials.
EU EMC Directive, the harmonized standards, European standards or the corresponding national standards. TR-Electronic GmbH 1998, All Rights Reserved Printed in the Federal Republic of Germany...
Assembly Instructions! Faults which could threaten safety should be eliminated without delay! 2.4 Intended use The IV20 pulse distributor is used in conjunction with an incremental encoder to extend the signal path in complex systems. Intended use also includes: •...
User Manual. • Repairs may only be undertaken by the manufacturer or a facility or person authorized by the manufacturer. TR-Electronic GmbH 1998, All Rights Reserved Printed in the Federal Republic of Germany 02/27/2024 TR-ECE-BA-GB-0057 v03...
Basic safety instructions 2.8 Personnel qualification; obligations • All work on the converter must only be carried out by qualified personnel. • Qualified personnel includes persons, who, through their training, experience and instruction, as well as their knowledge of the relevant standards, provisions, accident prevention regulations and operating conditions, have been authorized by the persons responsible for the system to carry out the required work and are able to recognize and avoid potential hazards.
Output level ..........5 V differential, 11…30 V, 30 mA each max. input impulse frequency ....150 kHz Pull-up/pull-down resistor ...... 1 k Weight ............ approx. 500 g TR-Electronic GmbH 1998, All Rights Reserved Printed in the Federal Republic of Germany 02/27/2024 TR-ECE-BA-GB-0057 v03...
Technical Data 4.2 Dimension drawing Plug version: Mating connector 10-pin Article no.: 62-005-017 (scope of delivery) * (Type Minicombicon) Plug housing 10-pin Article no.: 64-035-003 (not included in scope of delivery) (Type Minicombicon) * When ordering separately, the coding lugs must be removed according to the intended slot. ...
(Figure 1). Press the device housing against the mounting rail until the housing snaps into place on the mounting rail (Figure 2). Figure 1 Figure 2 TR-Electronic GmbH 1998, All Rights Reserved Printed in the Federal Republic of Germany 02/27/2024 TR-ECE-BA-GB-0057 v03...
With long supply lines for the incremental input data, a potential shift is to be expected for the incremental signal transmitter and IV20, even with the same power supply unit. It may then not be possible to evaluate the incremental data reliably. For this reason, the power supply of the IV20 is internally galvanically isolated from the signal ground.
Operating Mode 3: 11…30 V Open-Emitter (single-phase) Operating Mode 4: For explanations of the operating modes, see chapter 7.1 “Operating Modes”. TR-Electronic GmbH 1998, All Rights Reserved Printed in the Federal Republic of Germany 02/27/2024 TR-ECE-BA-GB-0057 v03 Page 15 of 20...
Installation / Preparation for commissioning 6.4 Connection 6.4.1 Incremental input X0 Pin no. Pin name Function Level 5 V diff., 11 V…30 V Input zero pulse 5 V diff., 11 V…30 V Input zero pulse, negated 5 V diff., 11 V…30 V Input signal 1 5 V diff., 11 V…30 V Input signal 1, negated...
6.5 Block Diagram galvanic isolation TR-Electronic GmbH 1998, All Rights Reserved Printed in the Federal Republic of Germany 02/27/2024 TR-ECE-BA-GB-0057 v03 Page 17 of 20...
Commissioning 7 Commissioning 7.1 Operating Modes 7.1.1 Operating Mode 1, Differential 5 V, 11…30 This operating mode corresponds to the basic configuration of the device for differential signal input levels. The device requires all incremental tracks (K0, K1, K2 and their negated signals) for this operating mode.
Connector X7 Principle diagram for input circuit Jumper 1: 1/4/ Jumper 2: 2/6/7 TR-Electronic GmbH 1998, All Rights Reserved Printed in the Federal Republic of Germany 02/27/2024 TR-ECE-BA-GB-0057 v03 Page 19 of 20...
Commissioning 7.2 Setting the output level The output level can be selected separately for each channel by means of a corresponding bridge coding in the mating connector: 2. 11…30 V output level 1. 5 V output level Connector X1…X6 Connector X1…X6 Jumper 1: 8/10 Jumper 1: 9/10 ...