Daihan Scientific JT-M6C Operation Manual

Digital jar tester

Advertisement

Quick Links

Certifications by
- - -
CE Marked Products.
ISO 9001 Certified.
PL Insurance.
Patented( No. 10-0554098) Jog Shuttle Control System.
Sales & Basic A/S :
By the Nearest Official Distributors.
Operation Manual
(Version 2.1.1)
JT-M6C models
"JT-M6C" Digital Jar Tester.
written for
Digital Jar Tester
² English Page : P. 11 ~ 23
² Korean Page : P. 24 ~ 40
Man.263 (1 Sep 2015)
JT-M6C

Advertisement

Table of Contents
loading

Summary of Contents for Daihan Scientific JT-M6C

  • Page 1 ² Korean Page : P. 24 ~ 40 Patented( No. 10-0554098) Jog Shuttle Control System. Operation Manual (Version 2.1.1) written for JT-M6C models “JT-M6C” Digital Jar Tester. Sales & Basic A/S : By the Nearest Official Distributors. Man.263 (1 Sep 2015)
  • Page 2 LAB.com DAIHAN-Sci.com or Shopping Mall European Declaration of Conformity We, DAIHAN Scientific Co., Ltd., Daihan Bldg., 24-4, Sangwolgok-dong, Seongbuk-gu, Seoul, Korea, Tel: 82-2-967-5235, Fax: 82-2-963-5231 declare under our sole responsibility that the product Jar Tester JT-M6C to which this declaration relates is in conformity...
  • Page 3: Table Of Contents

    LAB.com DAIHAN-Sci.com or Shopping Mall Contents Page 1. Safety Instructions ..............……..….. 4 2. Before Use ….................……..8 3. Introduction ..................9 4. Package Contents ................... 10 5. Appearance and Naming ................10 6. Installation ....………………............11 7. Cautions in Use ………………............... 13 8.
  • Page 4: Safety Instructions

    LAB.com DAIHAN-Sci.com or Shopping Mall Safety Instructions Please read this carefully for the safety before using the device. The indicated cautions are related to the safety and you should observe all safety and warning instructions. Symbols (Pictograms) and the meaning This symbol indicates caution This symbol indicates inhibition.
  • Page 5 LAB.com DAIHAN-Sci.com or Shopping Mall Do not handle the power cord harshly. Disconnection or short may cause if you bend or put a heavy thing on the device. When you take a plug out in a wall socket, turn the power off and then take the plug out carefully.
  • Page 6 LAB.com DAIHAN-Sci.com or Shopping Mall Do not install the device where it can get damp or dust. It may be caused overheating, a short circuit or a fire by damp or dust inside of the device. Do not use this device when temperature fall below 5°C and rise above 40°C. Do not use the device at a place with high temperature.
  • Page 7 LAB.com DAIHAN-Sci.com or Shopping Mall Avoid allowing objects to push or strike the hotplate or stirring plate of the machine. Do not put any objects insides. When an object that is easy to be combustible like a stone, a metal or paper goes inside, it may cause a fire, an electric shock or a break down.
  • Page 8: Before Use

    Product Liability (PL) Insurance Admission ¨ DAIHAN Scientific (Co., Ltd.) is a member of Product Liability Insurance (PL Insurance), so that its customers can trust our products, (believe and use its products,) by preparing against the accident which can be occurred during using the products by self-production.
  • Page 9: Introduction

    LAB.com DAIHAN-Sci.com or Shopping Mall Introduction “Digital” Digital Jar Testers are useful for Flocculation Testing in Water Treatment Laboratories. Those products have superior features as follows; n Ideal for Flocculation Testing in Water Treatment Laboratories n 6 independent light source for each Stirring Point(make a same condition of lights) n Digital Feedback Control using Microprocessor n Geared DC Motor and Specially Designed Timing Belt used n Stable and Accurate Stirring Speed by Feedback Control...
  • Page 10: Package Contents

    DAIHAN-Sci.com or Shopping Mall Package Contents □ Jar Tester .…..……..…..……..…………..……….…….......………… □ Power Cord ..……………………………………………………………………..…………………….. □ Operation Manual ..……………………………………………………………………………… Appearance and Naming The appearance of Digital Jar Tester. Controller Lamp Impeller <Figure 1> Appearance of JT-M6C 10 /40 Digital Jar Tester...
  • Page 11: Installation

    LAB.com DAIHAN-Sci.com or Shopping Mall Installation 1. After receiving the unit and putting it on the specified place of use, remove the wrapping. 2. Check the unit on eventual transport damages. In case there are some transport damages found please inform the forwarder and your contractor. If there is no damage please go to point 3.
  • Page 12 LAB.com DAIHAN-Sci.com or Shopping Mall Do not use the device at a place with high temperature. Do not operate the device near a heater, blowing an air-conditioner. It may be caused an accident by over- heating. The device should be set at a well ventilated place. Be sure the holes on the side or rear surface of the body are blocked by a wall or an object.
  • Page 13: Cautions In Use

    LAB.com DAIHAN-Sci.com or Shopping Mall Cautions in Use WARNING Be careful to operate the device. You MUST read this manual carefully and completely before using. The device should only be operated by laboratory personnel especially trained for this purpose and familiar with all precautionary measures required for working in a laboratory.
  • Page 14 LAB.com DAIHAN-Sci.com or Shopping Mall All the mechanisms and electric/electronic devices in this machine are designed and developed by the manufacturer. The devices could be disassembled and serviced only by the engineers of manufacturer or by engineers approved by manufacturer. Do not touch the device with wet hand while operation.
  • Page 15: Controller Details

    LAB.com DAIHAN-Sci.com or Shopping Mall Controller Details ① Set RPM. STIRRIN ③ Measured RPM. ④ Current Power POWER ② Set Program Button ⑥ Jog Shuttle switch (Turn & Push) ⑦ Lamp switch ⑤ Power switch <Figure 2> Controller of Digital Jar Tester ①...
  • Page 16: Operation

    LAB.com DAIHAN-Sci.com or Shopping Mall Operation 1. Preparation for Use l Connect the power cord to the proper power socket. l Put on the sample to the plate, l you turn on the power switch ⑤, the electrical power is applied to the unit and it goes into the pause mode.
  • Page 17 LAB.com DAIHAN-Sci.com or Shopping Mall 5. Power off For the safe use of homogenizer, you had better turn off the power switch after going into the pause mode by clicking the jog shuttle. 6. Program setting and operation Fig 3. Program setting button 1.
  • Page 18 LAB.com DAIHAN-Sci.com or Shopping Mall 3. Program running pause mode A. When running a program, If you want to pause a instrument. Push a jog shuttle. And then push a jog shuttle again. Jar Tester will running once more B. When running a program, If you want to cancel operation. Push a MODE button. (a) Setting mode (b) Select program (c) Start of setting (d) Time setting (e) Speed setting (f) Speed adjust (g) Save a value...
  • Page 19 LAB.com DAIHAN-Sci.com or Shopping Mall Self-Protect Functions 1. Overload protection : When the Jar Tester is stopped because of over-load due to over the capacity. (Temperature Sensing) 2. When Jar Tester goes into an abnormal operating condition such as a over condition and being prohibited by unexpected obstacles in the roller, the machine stops in order to protect the instrument.
  • Page 20: Specifications

    LAB.com DAIHAN-Sci.com or Shopping Mall Specifications 20 /40 Digital Jar Tester...
  • Page 21: Maintenance

    LAB.com DAIHAN-Sci.com or Shopping Mall Maintenance 1. If you don’t use the device for a long time, please plug out, dry up the machine and keep with packing. 2. When you need exchange of a component for repair, you MUST use an original component provided by manufacturer.
  • Page 22: Troubles & Solutions

    LAB.com DAIHAN-Sci.com or Shopping Mall Troubles and Solutions Situation Confirmations and Solutions Check the Set RPM. Not stirring Check if the MAIN power switch is ON. Check if the power cord is plugged. Power failure Check if the supplied electricity is proper and regulated. Check the fuse condition.
  • Page 23: Certificate

    4. This certification is only for international customers. Item Digital Jar Tester JT-M6C Model No. Serial No. Date Customer DAIHAN Scientific Co., Ltd. 326, Sinpyeongseokhwa-ro, jijeong-myeon, Wonj-si, Gangwon-do, Korea Tel : +82 2 967 5235 Fax : +82 963 5231 email : info@daihansci.co.kr www.DAIHAN-Sci.com www.ALL for LAB.com...