USE AND MAINTENANCE MANUAL TRANSLATION OF THE ORIGINAL INSTRUCTIONS – ENGLISH Codice NAKED Code Code Codigo GE 3500 HBM (STAGE V) CJ6N50109003 Kodezahl Código GE 3500 KBM (STAGE V) Код Code Kód Edizione Edition Édition • Gruppo Elettrogeno • Stromerzeuger •...
INDEX 0. GENERAL INFORMATION M1.1 INTRODUCTION ........................PAG. 4 M1.4 CE MARK ..........................PAG. 5 SYMBOLS AND SAFETY PRECAUTIONS ..................PAG. 6 WARNINGS ..........................PAG. 7 M2.1 M2.5 SAFETY RULES ........................PAG. 8 1. GENERAL INFORMATION OF THE MACHINE DESCRIPTION OF THE MACHINE .....................PAG. 10 RECORDING DATA ........................PAG.
INTRODUCTION Dear Customer, The Manufacturer shall not be liable for ANY USE OF THE PRO- We wish to thank you for having bought a high quality set. DUCT OTHER THAN THAT PRECISELY SPECIFIED IN THIS Our sections for Technical Service and Spare Parts will work at MANUAL and is thus not liable for any risks which may occur as best to help you if it were necessary.
CE MARKING GENERATING SETS Any of our product is labelled with CE marking attesting its conformity to appliable directives and also the fulfillment of safety requirements of the product itself; the list of these directives is part of the declaration of conformity included in any machine standard equipment.
SYMBOLS AND SAFETY PRECAUTIONS SYMBOLS IN THIS MANUAL DANGER - The symbols used in this manual are designed to call your GENERAL ADVICE - If the advice is not respec- attention to important aspects of the operation of the machine ted damage can happen to persons or things.
WARNINGS FIRST AID. In case the operator shold be sprayed by accident, from corrosive liquids a/o hot toxic gas or whate- ver event which may cause serious injuries or death, predispose the first aid in accordance with the ruling labour accident standards or of local instructions.
SAFETY RULES GENERATING SETS - LIGHTING TOWERS GENERAL SAFETY INSTRUCTIONS • Do not replace the tires with types different from the original + NOTE: the information contained in this manual are ones. subject to change without notice. • Check that the brakes and the optical signaling of the trailer are working properly.
Page 9
If the lighting tower is • Do not smoke, avoid any naked flames or sparks near the mounted on road trailer pull the handbrake. battery, the vapors exhaled could cause the battery to explo- •...
DESCRIPTION OF THE MACHINE GE 3500 HBM - KBM The generating set is a unit which transforms the mechanical energy, generated by combustion engine, into electric energy, through an alternator. The model GE3500 is a compact diesel generating set, is easily transported using a trolley.
RECORDING DATA The manual is for the range of machines indicated on the front cover. With the scope to facilitate the search of the spare parts and maintain information of the bought machine, is necessary to record some data. Please write the requested data inside the squares to side: Model of machine Serial number of the machine Serial number of the engine...
MACHINE UNPACKING NOTE Be sure that the lifting devices are: correctly mounted, adequate for the weight of the machine with it’s packaging, and conforms to local rules and regulations. When receiving the goods make sure that the product has not suffered damage during the transport, that there has not been rough handling or taking away of parts contained inside the packing or in the set.
TRANSPORT AND HANDLING COVERED UNITS ATTENTION Transportation must always take place with the engine off, electrical cables and starting battery disconnected and fuel tank empty. Be sure that the lifting devices are: correctly mounted, adequate for the weight of the machine with it’s packaging, and conform to local rules and regulations.
InstallatIon advIces environMental conditions General installation criteria Installation of a genset has to be planned by qualified and trained technicians, it has to be carried out by a competent attention organization with qualified personnel and proper equipment. attention Open gensets (SKID) have to be located in an area pro- tected from rain, snow, high humidity and direct exposure to the sun.
Page 16
InstallatIon advIces 2.6.1 saFe distance Fixed outdoor installation If a shelter is used to protect the genset (see figure), it should NOT be attached to it. attention Even if a shelter is temporary the below indications should be followed: A safe distance has to be kept between genset and fuel de- posits, inflammable goods (cloths, paper, etc.), chemicals, attention according to indications provided by the authority in char-...
Page 17
InstallatIon advIces 2.6.2 Sample of outdoor installation with shelter Floor should be levelled and suitable to sustain genset weight. Thresholds on doors and openings should have a barrier in or- der to avoid liquids leaking. In case it is not possible to provide a door with a barrier, the genset should have a collection base appropriate for the quantity of liquid it contains, in any case dimensions of collection base must be in accordance to the...
Page 18
InstallatIon advIces 2.6.3 For open gensets installed indoors, we recommend: Electro ventilator capacity can be calculated as follows: • The dimensions of the air outlets be such that they have at least the same area of the radiator; Transmitted heat [Kcal/h] •...
SET-UP FOR OPERATION (GASOLINE ENGINE) AIR COOLED BATTERY WITHOUT MAINTENANCE Check that the dry air filter is correctly installed and that there (WHEN ASSEBLED) are no leaks around the filter which could lead to infiltrations of non-filtered air to the inside of the motor. The supplied battery is generally ready for use.
Starting and Stopping (Honda gX 200 / 270 / 390 gaSoLinE EnginE) 26.1 check daily ATTENTION: Allow the start-up knob to re-enter slowly, avoiding having it knock against the motor and thereby damaging the start-up system. 5. Once the engine is started, with the starter off, let it turn for NOTE a few minutes before drawing the load.
STARTING - STOPPING (KOHLER GASOLINE ENGINE) 26.2 check daily ATTENTION: Allow the start-up knob to re-enter slowly, avoiding having it knock against the motor and thereby damaging the start-up system. NOTE Do not alter the primary conditions of regulation and do not touch the sealed parts.
COMANDI - CONTROLS - COMMANDES - MANDOS - BEDIENELEMENTE - COMANDOS СИСТЕМЫ УПРАВЛЕНИЯ - BEDIENING GE 3500 HBM - KBM GE 3500 KBM Y5 59B GE 3500 KBM Pos. Descrizione Description Description Referenzliste Presa di messa a terra Earth terminal Prise de mise à...
UsE As gEnErAtor OPERATING CONDITIONS WARNING POWER The electrical power expressed in kVA on an electricity- It is absolutely forbidden to connect the unit to the public generating group is the available output power to the reference mains and/or another electrical power source . environmental conditions and nominal values for: voltage, frequency, power factors (cos ϕ).
Page 24
UsE As gEnErAtor 37.1 The frequency, and therefore the number of motor revolutions, SINGLE-PHASE LOADS is maintained constant by the motor’s speed regulation system. Power to monophase utilities by means of three-phase Generally, this regulator is of a mechanical type and presents generators requires some operating limitations.
Page 25
UsE As gEnErAtor 37.2 DIFFERENTIAL SWITCH USAGE WITH EAS AUTOMATIC START-UP PANEL The differential switch or differential relay guarantee protection The electricity-generating group in combination with the EAS against indirect contacts due to malfunction currents towards the automatic start-up panel forms a unit for distributing electrical ground.
Page 26
UsE As gEnErAtor 12V C.B. 37.3 GENERATION IN C.C. (Continuous Current) ATTENTION Maximum power in c.c.: The batteries produce explosive gas; sparks, flames, cigaret- P = 120W - V= 12V AC tes, are to be kept far from them. Make sure that when they I = 10A are being recharged there is adequate ventilation around the battery.
TROUBLESHOOTING 40.2 WARNING ● Have qualified personnel do maintenance and troubleshooting work. ● Stop the engine before doing any work inside the machine. If for any reason the machine must be operated while working inside, pay attention mo- ving parts, hot parts (exhaust manifold and muffler, etc.) electrical parts which may be unprotected when the machine is open. ●...
Page 28
TROUBLESHOOTING 40.2.1 GENERATOR Absence of output voltage 1) Protection tripped due to overload 1) Check the load connected and decrease 2) Differential protection device tripped 2) Check the insulation of the whole system: wiring, connections, connected load and check that there are no insulation fault that cause leakage currents to earth 3) Protection devices defective 3) Replace...
MAINTENANCE WARNING ● Have qualified personnel do maintenance and troubleshooting work. ● Stop the engine before doing any work inside the machine. If for any reason the machine must be operated while working inside, pay at- tention moving parts, hot parts (exhaust manifold and muffler, etc.) electrical parts which may be unprotected when the machine is open.
STORAGE And diSASSEmblE STORAGE DISASSEMBLE + Have qualified personnel disassemble the machine and In case the machine should not be used for more than 30 days, dispose of the parts, including the oil, fuel, etc., in a correct make sure that the room in which it is stored presents a suitable manner when it is to be taken out of service.
TECHNICAL DATE GE 3500 HBM GE 3500 KBM GENERATOR *Stand-by single-phase power 3.2 kVA (2.9 kW) / 230 V / 13.9 A *PRP single-phase power 2.9 kVA (2.6 kW) / 230 V / 12.6 A *Stand-by single-phase power 3.2 kVA (2.9 kW) / 115 V / 27.8 A *PRP single-phase power 2.9 kVA (2.6 kW) / 115 V / 25.2 A...