Advertisement

Quick Links

USE AND MAINTENANCE MANUAL
TRANSLATION OF THE ORIGINAL INSTRUCTIONS – ENGLISH
NAKED
GE 3500 HBM (STAGE V)
GE 3500 KBM (STAGE V)
• Gruppo Elettrogeno
• Stromerzeuger
• Generating Set
• Grupo Gerador
• Groupe Electrogene
• Генераторная Установка
• Grupos Electrógenos
• Stroomaggregaten
M A D E
I N
• Skupina generátoru
I T A L Y
language
Codice
Code
Code
Codigo
CJ6N50109003
Kodezahl
Código
Код
Code
Kód
Edizione
Edition
Édition
Edición
10.2019
Ausgabe
Edição
Издание
Editie
Edice

Advertisement

Table of Contents
loading

Summary of Contents for Naked GE 3500 HBM

  • Page 1 USE AND MAINTENANCE MANUAL TRANSLATION OF THE ORIGINAL INSTRUCTIONS – ENGLISH Codice NAKED Code Code Codigo GE 3500 HBM (STAGE V) CJ6N50109003 Kodezahl Código GE 3500 KBM (STAGE V) Код Code Kód Edizione Edition Édition • Gruppo Elettrogeno • Stromerzeuger •...
  • Page 3: Table Of Contents

    INDEX 0. GENERAL INFORMATION M1.1 INTRODUCTION ........................PAG. 4 M1.4 CE MARK ..........................PAG. 5 SYMBOLS AND SAFETY PRECAUTIONS ..................PAG. 6 WARNINGS ..........................PAG. 7 M2.1 M2.5 SAFETY RULES ........................PAG. 8 1. GENERAL INFORMATION OF THE MACHINE DESCRIPTION OF THE MACHINE .....................PAG. 10 RECORDING DATA ........................PAG.
  • Page 4: Introduction

    INTRODUCTION Dear Customer, The Manufacturer shall not be liable for ANY USE OF THE PRO- We wish to thank you for having bought a high quality set. DUCT OTHER THAN THAT PRECISELY SPECIFIED IN THIS Our sections for Technical Service and Spare Parts will work at MANUAL and is thus not liable for any risks which may occur as best to help you if it were necessary.
  • Page 5: Ce Mark

    CE MARKING GENERATING SETS Any of our product is labelled with CE marking attesting its conformity to appliable directives and also the fulfillment of safety requirements of the product itself; the list of these directives is part of the declaration of conformity included in any machine standard equipment.
  • Page 6: Symbols And Safety Precautions

    SYMBOLS AND SAFETY PRECAUTIONS SYMBOLS IN THIS MANUAL DANGER - The symbols used in this manual are designed to call your GENERAL ADVICE - If the advice is not respec- attention to important aspects of the operation of the machine ted damage can happen to persons or things.
  • Page 7: Warnings

    WARNINGS FIRST AID. In case the operator shold be sprayed by accident, from corrosive liquids a/o hot toxic gas or whate- ver event which may cause serious injuries or death, predispose the first aid in accordance with the ruling labour accident standards or of local instructions.
  • Page 8: Safety Rules

    SAFETY RULES GENERATING SETS - LIGHTING TOWERS GENERAL SAFETY INSTRUCTIONS • Do not replace the tires with types different from the original + NOTE: the information contained in this manual are ones. subject to change without notice. • Check that the brakes and the optical signaling of the trailer are working properly.
  • Page 9 If the lighting tower is • Do not smoke, avoid any naked flames or sparks near the mounted on road trailer pull the handbrake. battery, the vapors exhaled could cause the battery to explo- •...
  • Page 10: Description Of The Machine

    DESCRIPTION OF THE MACHINE GE 3500 HBM - KBM The generating set is a unit which transforms the mechanical energy, generated by combustion engine, into electric energy, through an alternator. The model GE3500 is a compact diesel generating set, is easily transported using a trolley.
  • Page 11: Recording Data

    RECORDING DATA The manual is for the range of machines indicated on the front cover. With the scope to facilitate the search of the spare parts and maintain information of the bought machine, is necessary to record some data. Please write the requested data inside the squares to side: Model of machine Serial number of the machine Serial number of the engine...
  • Page 12: Machine Unpacking

    MACHINE UNPACKING NOTE Be sure that the lifting devices are: correctly mounted, adequate for the weight of the machine with it’s packaging, and conforms to local rules and regulations. When receiving the goods make sure that the product has not suffered damage during the transport, that there has not been rough handling or taking away of parts contained inside the packing or in the set.
  • Page 13: M4.1 Transport And Displacements Covered Units

    TRANSPORT AND HANDLING COVERED UNITS ATTENTION Transportation must always take place with the engine off, electrical cables and starting battery disconnected and fuel tank empty. Be sure that the lifting devices are: correctly mounted, adequate for the weight of the machine with it’s packaging, and conform to local rules and regulations.
  • Page 14 INSTALLAZIONE - INSTALLATION - INSTALLATION - INSTALACIÓN LUFTZIRKULATION - INSTALAÇÃO - УСТАНОВКА - INSTALLATIE GE 3500 HBM - KBM...
  • Page 15: Installation

    InstallatIon advIces environMental conditions General installation criteria Installation of a genset has to be planned by qualified and trained technicians, it has to be carried out by a competent attention organization with qualified personnel and proper equipment. attention Open gensets (SKID) have to be located in an area pro- tected from rain, snow, high humidity and direct exposure to the sun.
  • Page 16 InstallatIon advIces 2.6.1 saFe distance Fixed outdoor installation If a shelter is used to protect the genset (see figure), it should NOT be attached to it. attention Even if a shelter is temporary the below indications should be followed: A safe distance has to be kept between genset and fuel de- posits, inflammable goods (cloths, paper, etc.), chemicals, attention according to indications provided by the authority in char-...
  • Page 17 InstallatIon advIces 2.6.2 Sample of outdoor installation with shelter Floor should be levelled and suitable to sustain genset weight. Thresholds on doors and openings should have a barrier in or- der to avoid liquids leaking. In case it is not possible to provide a door with a barrier, the genset should have a collection base appropriate for the quantity of liquid it contains, in any case dimensions of collection base must be in accordance to the...
  • Page 18 InstallatIon advIces 2.6.3 For open gensets installed indoors, we recommend: Electro ventilator capacity can be calculated as follows: • The dimensions of the air outlets be such that they have at least the same area of the radiator; Transmitted heat [Kcal/h] •...
  • Page 19: Set-Up For Operation Gasoline Engine

    SET-UP FOR OPERATION (GASOLINE ENGINE) AIR COOLED BATTERY WITHOUT MAINTENANCE Check that the dry air filter is correctly installed and that there (WHEN ASSEBLED) are no leaks around the filter which could lead to infiltrations of non-filtered air to the inside of the motor. The supplied battery is generally ready for use.
  • Page 20: M26.1 Starting And Stopping Honda Gasoline Engine

    Starting and Stopping (Honda gX 200 / 270 / 390 gaSoLinE EnginE) 26.1 check daily  ATTENTION: Allow the start-up knob to re-enter slowly, avoiding having it knock against the motor and thereby damaging the start-up system. 5. Once the engine is started, with the starter off, let it turn for NOTE a few minutes before drawing the load.
  • Page 21: M26.2 Starting And Stopping Kholer Gasoline Engine

    STARTING - STOPPING (KOHLER GASOLINE ENGINE) 26.2 check daily  ATTENTION: Allow the start-up knob to re-enter slowly, avoiding having it knock against the motor and thereby damaging the start-up system. NOTE Do not alter the primary conditions of regulation and do not touch the sealed parts.
  • Page 22: M31 Controls (Ge 3500 Hbs)

    COMANDI - CONTROLS - COMMANDES - MANDOS - BEDIENELEMENTE - COMANDOS СИСТЕМЫ УПРАВЛЕНИЯ - BEDIENING GE 3500 HBM - KBM GE 3500 KBM Y5 59B GE 3500 KBM Pos. Descrizione Description Description Referenzliste Presa di messa a terra Earth terminal Prise de mise à...
  • Page 23: M37

    UsE As gEnErAtor OPERATING CONDITIONS WARNING POWER The electrical power expressed in kVA on an electricity- It is absolutely forbidden to connect the unit to the public generating group is the available output power to the reference mains and/or another electrical power source . environmental conditions and nominal values for: voltage, frequency, power factors (cos ϕ).
  • Page 24 UsE As gEnErAtor 37.1 The frequency, and therefore the number of motor revolutions, SINGLE-PHASE LOADS is maintained constant by the motor’s speed regulation system. Power to monophase utilities by means of three-phase Generally, this regulator is of a mechanical type and presents generators requires some operating limitations.
  • Page 25 UsE As gEnErAtor 37.2 DIFFERENTIAL SWITCH USAGE WITH EAS AUTOMATIC START-UP PANEL The differential switch or differential relay guarantee protection The electricity-generating group in combination with the EAS against indirect contacts due to malfunction currents towards the automatic start-up panel forms a unit for distributing electrical ground.
  • Page 26 UsE As gEnErAtor 12V C.B. 37.3 GENERATION IN C.C. (Continuous Current) ATTENTION Maximum power in c.c.: The batteries produce explosive gas; sparks, flames, cigaret- P = 120W - V= 12V AC tes, are to be kept far from them. Make sure that when they I = 10A are being recharged there is adequate ventilation around the battery.
  • Page 27: M40.2

    TROUBLESHOOTING 40.2 WARNING ● Have qualified personnel do maintenance and troubleshooting work. ● Stop the engine before doing any work inside the machine. If for any reason the machine must be operated while working inside, pay attention mo- ving parts, hot parts (exhaust manifold and muffler, etc.) electrical parts which may be unprotected when the machine is open. ●...
  • Page 28 TROUBLESHOOTING 40.2.1 GENERATOR Absence of output voltage 1) Protection tripped due to overload 1) Check the load connected and decrease 2) Differential protection device tripped 2) Check the insulation of the whole system: wiring, connections, connected load and check that there are no insulation fault that cause leakage currents to earth 3) Protection devices defective 3) Replace...
  • Page 29: Maintenance

    MAINTENANCE WARNING ● Have qualified personnel do maintenance and troubleshooting work. ● Stop the engine before doing any work inside the machine. If for any reason the machine must be operated while working inside, pay at- tention moving parts, hot parts (exhaust manifold and muffler, etc.) electrical parts which may be unprotected when the machine is open.
  • Page 30: M45 Storage And Cast Off

    STORAGE And diSASSEmblE STORAGE DISASSEMBLE + Have qualified personnel disassemble the machine and In case the machine should not be used for more than 30 days, dispose of the parts, including the oil, fuel, etc., in a correct make sure that the room in which it is stored presents a suitable manner when it is to be taken out of service.
  • Page 31: Technical Data

    TECHNICAL DATE GE 3500 HBM GE 3500 KBM GENERATOR *Stand-by single-phase power 3.2 kVA (2.9 kW) / 230 V / 13.9 A *PRP single-phase power 2.9 kVA (2.6 kW) / 230 V / 12.6 A *Stand-by single-phase power 3.2 kVA (2.9 kW) / 115 V / 27.8 A *PRP single-phase power 2.9 kVA (2.6 kW) / 115 V / 25.2 A...
  • Page 32 DIMENSIONI - DIMENSIONS - DIMENSIONS - DIMENSIONES - ABMESSUNGEN DIMENSÕES - РАЗМЕРЫ - AFMETINGEN 2.7.1 GE 3500 HBM - KBM...
  • Page 33: Electrical System Legende

    ELECTRICAL SYSTEM LEGENDE : Alternator E3 : Open circuit voltage switch I6 : Start Local/Remote selector N9 : UP/DOWN button mast : Wire connection unit F3 : Stop push-button L6 : Choke button O9 : Hydraulic unit solenoid valve C : Capacitor G3 : Ignition coil M6 : Switch CC/CV P9 : Hydraulic unit engine...
  • Page 34: M61

    SCHEMA ELETTRICO - ELECTRIC DIAGRAM - SCHEMAS ELECTRIQUES - ESQUEMA ELÉCTRICO - STROM- LAUFPLAN - ESQUEMA ELÉCTRICO - ЛЕГЕНДА ЭЛЕКТРИЧЕСКАЯ СХЕМА - ELECTRISCH GEDEELTE GE 3500 KBM | GE 5000 BBM...
  • Page 35 SCHEMA ELETTRICO - ELECTRIC DIAGRAM - SCHEMAS ELECTRIQUES - ESQUEMA ELÉCTRICO - STROM- LAUFPLAN - ESQUEMA ELÉCTRICO - ЛЕГЕНДА ЭЛЕКТРИЧЕСКАЯ СХЕМА - ELECTRISCH GEDEELTE 61.1 GE 3500 HBM | GE 5000 HBM | GE 7000 HBM | GE 8000 HBT...
  • Page 36 SCHEMA ELETTRICO - ELECTRIC DIAGRAM - SCHEMAS ELECTRIQUES - ESQUEMA ELÉCTRICO - STROM- LAUFPLAN - ESQUEMA ELÉCTRICO - ЛЕГЕНДА ЭЛЕКТРИЧЕСКАЯ СХЕМА - ELECTRISCH GEDEELTE 61.2 GE 3500 HBM - KBM | GE 4000 KDM | GE 5000 HBM - BBM...
  • Page 37 SCHEMA ELETTRICO - ELECTRIC DIAGRAM - SCHEMAS ELECTRIQUES - ESQUEMA ELÉCTRICO - STROM- LAUFPLAN - ESQUEMA ELÉCTRICO - ЛЕГЕНДА ЭЛЕКТРИЧЕСКАЯ СХЕМА - ELECTRISCH GEDEELTE GE 3500 KBM...
  • Page 38 NOTE...
  • Page 40 MOSA div. della BCS S.p.A. Viale Europa, 59 20090 Cusago (Milano) Italy Tel.+39 - 0290352.1 Fax +39 - 0290390466 www.mosa.it...

This manual is also suitable for:

Ge 3500 kbmCj6n50109003

Table of Contents