WS755 Water Sampler
Publication Number 39160314
01-957
- 1 -

Advertisement

Table of Contents
loading

Summary of Contents for Global Water WS755

  • Page 1 Global Water Global Water Instrumentation, Inc. WS755 Water Sampler Publication Number 39160314 01-957 - 1 -...
  • Page 2: Table Of Contents

    • XVI. Appendix B: Battery Life • • • • XVII. Appendix C: Input and Output Connections • • • XVIII. Appendix D: Accessories • • • • • * Copyright  Global Water Instrumentation, Inc. 2014 - 2 -...
  • Page 3: Ws755 Checklist Page

    Congratulations on your purchase of the Global Water WS755 Water Sampler. This instrument has been quality tested and approved for accurate and reliable operation. We are confident that you will find the WS755 to be a valuable asset for your applications. Should you require assistance, our technical staff will be happy to help.
  • Page 4 The WS755 Sampler can take two individual “time weighted” composite samples, or the sampler can be set to take full-bottle discrete or “Grab” samples. Each pump has its own sample bottle and control for setting the size of individual samples.
  • Page 5: Installing The Water Sampler

    Global Water IV. Installing the Water Sampler a. The sampler should be placed upright (it will not work if placed on its back or side). b. Remove the pickup hoses and connect to the sampler using the quick- disconnect fittings on the side of the enclosure. Place the protective caps over the protective quick-disconnect plugs and save for future use.
  • Page 6: The Control Panel

    Global Water The Control Panel 1. Pump One. 2. Pump Two. 3. Start Delay: This setting delays sampling by a preset amount of time. If no delay is desired, set the control to zero. Only the first sample taken by each pump is delayed, except as described later in the section titled “External Trigger Mode”.
  • Page 7 Global Water more detail later in the section titled “External Trigger Mode”. Refer to the Specifications section for details about the input pulse requirements. 8. Pulse Out: These outputs send a pulse to an optional recording or monitoring device each time the corresponding pump starts, allowing the time of the sample event to be recorded.
  • Page 8: Composite Sampling

    Global Water VI. Composite Sampling A composite sample is a series of smaller samples put into the same bottle, thus showing an “average” sample over time. Set the Interval control to the desired time between samples (do not select the External Trigger position). Set the Size control for the corresponding pump to the desired sample size.
  • Page 9: Mixed Sampling

    Global Water VIII. Mixed Sampling, Composite and Discrete Sampler The WS755 Sampler can be configured as both a composite and discrete sampler at the same time since each pump has a separate Size control. Set one pump’s size setting to the desired composite sample size and the other to “Full”.
  • Page 10 Flow Proportional Sampling a. To set the WS755 up to take flow proportional samples, a flow monitor must be attached to the control panel. In this configuration, the sampler is designed to take a sample every time a specific amount of flow has passed through the flow monitor.
  • Page 11: Specifications

    Global Water XI. Specifications Operating Temperature: 0° to +70°C Dimensions 22”H X 18"W X 10"D Weight: 30lb (Shipping Weight 32lbs) Materials: Enclosure: Expanded UV protected PVC Bottles: Two 1 gallon Polyethylene Pickup Hoses: 15' nylon reinforced 1/4" ID polyethylene flexible tubing with 20-Mesh intake strainers and quick-disconnect fittings.
  • Page 12: Maintenance

    Global Water XII. Maintenance Sampler The Global Water WS755 Water Sampler requires minimal maintenance. The sampler enclosure is rainproof and rugged. Avoid exposure to extremely rough usage. Routinely wipe the carrying case and control panel face, rinse the pickup hose and debris strainer, and wash the sample bottles with mild soap and warm water.
  • Page 13: Troubleshooting

    Global Water XIII. Troubleshooting a. Check that the battery is firmly connected to the control panel and confirm that it is fully charged. b. Press the Pump Test buttons on the front panel. The test buttons should always run the pumps, regardless of the state of any of the inputs.
  • Page 14: Warranty

    5. Repair instructions and/or specific problems relating to the product. IXV. Warranty a. Global Water Instrumentation, Inc. warrants that its products are free from defects in material and workmanship under normal use and service for a period of one year from date of shipment from factory. Global Water’s obligations under this warranty are limited to, at Global Water’s option: (I)
  • Page 15: Appendix A: Sample Size Vs. Head Height

    Global Water Appendix A: Sample Size vs. Head Height Use the following graph to see how sample size changes with head height. The Sample Size controls on the control panel are calibrated at a height of 4 feet. Increasing the head height decreases the sample size by a predictable amount.
  • Page 16: Appendix B: Battery Life

    ½ hour (5 gallons). To prevent large current surges which occur when the pumps first turn on, the WS755 is designed so that only one pump will turn on or off at a time. A ½ second time delay is inserted between these events, extending the life of the charge and the life of the battery.
  • Page 17: Appendix D: Accessories

    Global Water Appendix D: Accessories Part Description Part Number Unit 12V 4 Ah NiMH Battery 329417 Each NiMH Battery Charger 329585 Each 1 Gallon Plastic Sample Bottle 00-418 Each 1 Gallon Plastic Bottle Cap/Float Switch CB0200 Each Replacement Pickup Hose...