6.
Detach circuit breaker (item 3) from its mounting by re-
moving its attaching hardware (four screws).
7.
Remove protective tape from terminals' at end of drawer's
ac power cord.
8.
Route drawer's ac power cord through right-angle connec-
tor and into circuit breaker box.
Make a 360
0
service
loop and place loop flat on bottom of cabinet (see
Figure 2-11).
9.
Referring to Figure 2-10, install ac power cord as
fo llows :
a.
Connect brown wire on ac cord to circuit breaker
terminal A2.
b.
Connect blue wire on ac cord to circuit breaker
terminal 82.
c.
Connect green wire on ac cord to FRAME GROUND stud
within circuit breaker box.
10.
Remount circuit breaker (Table
2~3,
item 3) to front of
circuit breaker box using attaching hardware.
11.
Ensure that all wire terminals on circuit breaker's
terminals are securely fastened by testing them and
tightening them as necessary.
12.
Tighten cable clamp (item 8) holding ac power cord from
upper unit of cabinet.
13.
Replace circuit breaker box cover (item 17) by fastening
the three sets of attaching hardware (items 14, 15, and
16) •
2-23