4.6 Azimuth Check
1. Insert an alignment diskette.
2.
Step to track
40.
3.
Synchronize oscilloscope on IX (-INDEX), and set time base to 20 ms/division (DAD) or to 0.5 ms/division (CE).
4.
Connect one probe to
T1
and the other to
T2.
Ground the probes to GND and AG. Set inputs to AC Add, and
invert one channel. Set vertical deflection to
5
mV/division (DAD). or to
0.1
mV/division (CE).
5.
Measure as shown in
Fig. 4.4.
6.
Check that the measured value is within ±
24
minutes.
B
C
A
Azimuth O waveforms
B
c
c
D
A
B
A
D
If B
>
C
If B
<
C
B - C
@
@:30' (CE)
Azimuth= B _ D x
A
15 , (DAD)
C- B
@
@:30• (CE)
Azimuth=
c:A
x
A
15 , (DAD)
Fig. 4.4
Azimuth Waveforms
4. 7 Index Burst Check
1. Insert an alignment diskette.
2. Step to track
40.
3. ·Synchronize oscilloscope on IX (+ INDEX), and set time base to 20 ms/division (DAD).
4. Connect one probe to
Tl
and the other to T2. Ground the probes to GND and AG. Set inputs to AC Add, and
invert one channel. Set vertical deflection to 2 mV/division (DAD).
5. Check that timing between oscilloscope start and first data pulse is 3 ± 1.7 ms (DAD).
-8-