Page 3
Customer's right to recover damages caused by fault or negligence on the part of National Instruments shall be limited to the amount theretofore paid by the customer. National Instruments will not be liable for damages resulting from loss of data, profits, use of products, or incidental or consequential damages, even if advised of the possibility thereof.
Page 5
Table of Contents Backplane Fuse Replacement and Check Procedure for SCXI-1000, SCXI-1001, and SCXI-2000 ..........2-19 Fuse Replacement for the SCXI-1000DC............2-21 Power Entry Fuse and +5 VDC Fuse Replacement Procedure ..2-21 Backplane Fuse Replacement and Check Procedure....... 2-22 Chassis Installation.......................
SCXI-1000/1001/2000 Voltage Selection and Fuse Ratings by Region....................2-18 Table 2-7. SCXI-1000/1001/2000 Fuse Part Numbers ........... 2-18 Table 2-8. SCXI-1000/1001/2000 Backplane Fuse Part Numbers ......2-20 Table 2-9. SCXI-1000DC Rear Panel Fuse Part Numbers ........2-21 Table 2-10. SCXI-1000DC Backplane Fuse Part Numbers........2-22 Table 2-11.
Page 7
Appendix A, Specifications, lists the specifications for the SCXI chassis. • Appendix B, Customer Communication, contains forms you can use to request help from National Instruments or to comment on our products and manuals. • The Glossary contains an alphabetical list and description of terms used in this manual, including abbreviations, acronyms, metric prefixes, mnemonics, and symbols.
Page 8
SCXIbus <signal name> line (or signal). The SCXIbus descriptor may be omitted when the meaning is clear. SCXI chassis SCXI chassis or simply chassis refers to the SCXI-1000, SCXI-1000DC, SCXI-1001, and SCXI-2000. When information pertains to only one chassis, that chassis is named explicitly; for example, the SCXI-1001 has 12 module slots.
Page 10
SCXI-1000, SCXI-1000DC, and SCXI-1001. It does not contain remote programming information for the SCXI-2000 unless you are using it in SCXI-1000 mode. This manual is available from National Instruments by request. If you are using NI-DAQ, LabVIEW, or LabWindows/CVI, you should not need the register-level programmer manual.
Page 11
SCXI chassis kit. About the SCXI Chassis The SCXI-1000, SCXI-1000DC, and SCXI-2000 are four-slot SCXI chassis and the SCXI-1001 is a 12-slot SCXI chassis. All the chassis house National Instruments SCXI modules. The SCXI-1000, SCXI-1001, and SCXI-2000 chassis are powered with standard AC power.
Page 12
NI-DAQ for PC compatibles Your computer Software Programming Choices There are several options to choose from when programming your National Instruments plug-in DAQ and SCXI hardware. You can use LabVIEW, LabWindows/CVI, NI-DAQ, or register-level programming. LabVIEW and LabWindows/CVI Application Software LabVIEW and LabWindows/CVI are innovative program development software packages for data acquisition and control applications.
Chapter 1 Introduction NI-DAQ Driver Software The NI-DAQ driver software is included at no charge with all National Instruments DAQ hardware and the SCXI-2000 chassis. NI-DAQ has an extensive library of functions that you can call from your application programming environment. These functions include routines for analog...
Page 14
Chapter 1 Introduction Register-Level Programming The final option for programming any National Instruments DAQ hardware is to write register-level software. Writing register-level programming software can be very time-consuming and inefficient and is not recommended. Even if you are an experienced register-level programmer, consider using NI-DAQ, LabVIEW, or LabWindows/CVI to program your National Instruments DAQ hardware.
Unpacking Remove the chassis from the package and inspect the chassis for loose components or any other sign of damage. Notify National Instruments if the chassis appears damaged in any way. Do not install a module into a damaged SCXI chassis.
Brings power, control lines, and analog bus connections to modules Front-threaded strips Secure modules in the chassis and attaches front panels DIP switches Determine the chassis address (SCXI-1000, SCXI-1001, and SCXI-2000) and baud rate (SCXI-2000 only) 9-pin DSUB RS-232 connector (SCXI-2000 only)
Chapter 2 Configuration and Installation Table 2-2. SCXI-1000/1001 Chassis Rear View Items Item Description Power entry module IEC receptacle for power input, voltage selection board, and fuse Fuse Protects both you and the chassis in case of a fault in the SCXI chassis...
Page 28
0 and the switch setting for chassis address 19. Note: Older SCXI-1001 and SCXI-1000 chassis do not have switches; they use jumpers like those on the SCXI-1000DC. Very old SCXI-1000 chassis do not have switches or jumpers and respond to any address. (To determine if your chassis has no jumpers, look at the label on the back of your chassis.
Page 31
DAQ device to control multiple chassis), you must specify the address of the chassis as if it were an SCXI-1000. Set the address on the chassis with switches 1 through 5 on the front panel of the SCXI-2000 to select an address between 0 and 31 (switches 6 through 8 are not used).
If you are not controlling your chassis via its serial port, set the four baud rate switches to the SCXI-1000 setting shown in Table 2-5. The chassis will operate like an SCXI-1000 chassis and the serial ports and parallel port will not function.
Reserved Functions as SCXI-1000 Voltage Selection and Fuse Replacement for SCXI-1000/1001/2000 If you have ordered your chassis with the appropriate part number (the -0x extension of the kit part number corresponds to your geographical region), the voltage selection wheel and fuse will be correct for operation in your geographical region.
Caution: For continued protection against fire, replace fuses only with fuses of the same type and rating. Table 2-6. SCXI-1000/1001/2000 Voltage Selection and Fuse Ratings by Region Region Line Voltage Fuse Rating...
On the SCXI-1000 and SCXI-2000, the backplane fuses are located behind the fan. On the SCXI-1001, the backplane fuses are located behind the rightmost fan, closest to the power entry module, as viewed from the rear of the chassis.
(F1) is a 6.3 A, 5 x 20 mm time lag fuse. The internal +5 VDC supply is fused by a 3.15 A, 5 x 20 mm time lag fuse (F2). Table 2-9 shows the manufacturer part numbers National Instruments uses for these fuses.
In addition to the power entry and the +5 V supply fuses, the analog supply lines on the backplane are fused at 1.5 A on the SCXI-1000DC chassis. The manufacturer part number National Instruments uses for this fuse is given in Table 2-10.
Page 39
Category II environment per IEC 644. This category requires local level supply mains-connected installation. SCXI-1000 and SCXI-1001 Chassis Installation Use the following procedure to install the SCXI-1000 and SCXI-1001 chassis: 1. If necessary, change the chassis address of the box by following the instructions in the Chassis Address Selection section earlier in this chapter.
Page 40
Caution: Connecting the power source with opposite polarity may cause permanent damage to the SCXI chassis. National Instruments is liable for any damage or injuries resulting from improper power connections. 6. Insert the power plug into the header J1.
If your switch settings are invalid, only the PROG and TEST LEDs will flash on and off together. • If the chassis is ready for normal operation and set for SCXI-1000 mode, the PROG, TEST, and ONLINE LEDs will flash in sequence.
TEST, PROG, and Return the chassis for servicing. ONLINE flash simultaneously TEST, PROG, and If you are using SCXI-1000 mode, check the address switches, baud ONLINE flash in rate switches, and configuration in NI-DAQ Configuration Utility for sequence but nothing the chassis.
Page 50
Appendix A Specifications Physical Weight SCXI-1000 ..........3.9 kg (8 lb 10 oz.) SCXI-1000DC........3.3 kg (7 lb 5 oz.) SCXI-1001 ..........6.8 kg (14 lb 14 oz.) SCXI-2000 ..........3.8 kg (8 lb 8 oz.) Refer to the following figures for the physical dimensions of the 4-slot chassis (SCXI-1000, SCXI-1000DC, and SCXI-2000) and the 12-slot chassis (SCXI-1001).
Page 53
Electronic Services Bulletin Board Support National Instruments has BBS and FTP sites dedicated for 24-hour support with a collection of files and documents to answer most common customer questions. From these sites, you can also download the latest instrument drivers, updates, and example programs. For recorded instructions on how to use the bulletin board and FTP services and for BBS automated information, call (512) 795-6990.
Page 54
Fax and Telephone Support National Instruments has branch offices all over the world. Use the list below to find the technical support number for your country. If there is no National Instruments office in your country, contact the source from which you purchased your software to obtain support.
Page 55
National Instruments for technical support helps our applications engineers answer your questions more efficiently. If you are using any National Instruments hardware or software products related to this problem, include the configuration forms from their user manuals. Include additional pages if necessary.
Page 56
SCXI Chassis Hardware Configuration Form Record the settings and revisions of your hardware and software on the line to the right of each item. Also fill out the hardware and software configuration forms for all modules in the chassis, all relevant DAQ boards, and all other chassis in the application. By completing these forms accurately, our applications engineers will be able to answer your questions efficiently.
Page 57
Documentation Comment Form National Instruments encourages you to comment on the documentation supplied with our products. This information helps us provide quality products to meet your needs. Title: SCXI™ Chassis User Manual Edition Date: November 1996 Part Number: 320423D-01 Please comment on the completeness, clarity, and organization of the manual.