Satrue SUC-A Series Operation Manual

Counting scale

Advertisement

Quick Links

COUNTING SCALE
SUC-A & MAX-C Series
OPERATION MANUAL
SHANG CHUEN WEIGHTING MACHINE CO., LTD.
53, LIAO-YANG 4TH ST. TAICHUNG CITY, TAIWAN
TEL: 886-4-22453226 FAX: 886-4-22435042
E-MAIL :
hiture@satrue.com.tw
Website:
www.satrue.com.tw
Edition: Jun-2021
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SUC-A Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Satrue SUC-A Series

  • Page 1 COUNTING SCALE SUC-A & MAX-C Series OPERATION MANUAL SHANG CHUEN WEIGHTING MACHINE CO., LTD. 53, LIAO-YANG 4TH ST. TAICHUNG CITY, TAIWAN TEL: 886-4-22453226 FAX: 886-4-22435042 E-MAIL : hiture@satrue.com.tw Website: www.satrue.com.tw Edition: Jun-2021...
  • Page 2 PREFACE Thank you for purchasing this high precision type electronic counting scale. For a longer usage of the scale, please read the instruction manual completely before operation and keep it for further reference. CAUTION Never immerse the scale in water and other liquids, or place heavy metal ...
  • Page 3 BUTTON FUNCTION DESCRIPTION: Numeric keys “0~9”: To input number for unit weight or quantity of  sampling. Please setup number in 8 seconds, or it will clear to “0” automatically after 8 seconds. “0”:  1. To set “0”. 2. Press and hold “0”for 3 seconds to turn on/off automatic print. “•”: ...
  • Page 4 DISPLAY MESSAGES: “00000~99999”: When switching on the scale, the display will read through 0~9 automatically for about 3~5 seconds and set to 0. Buzzer alarm with each keypad touching, in order to confirm the correct operation. Backlight: Backlight turns on/off when press “ZERO” key for 3 seconds. ZERO indicator: An arrow will point to ZERO when “ZERO”...
  • Page 5 Sampling Principle: 1. Pick up a suitable capacity: Each unit weight should close to division (or minimum capacity), the closer the more precise. 2. Choose a suitable quantity: The larger the sampling size is, the more accurate the unit weight is. If possible, sample at least 1/2 of total quantity (the more the better).
  • Page 6 Example: 30 kg calibration 1. Press 【WS】5 seconds SET UP 2.Press 【1】 zero point PRO-1 4XXX 3500-6000 If the value is not within this area. Adjust M/B VR3 3.Press 【1】 100K. PRO-2 4XXX 4.Put the standard weight unit (EX:10 kg) on the scale (the unit is based on full scale weight), for example, to calibrate a 30 kg scale, the standard weight unit you can select is 10 kg, 15 kg or 30 kg) PRO-2...