AMS 2000 Operation Manual Make sure to read this manual to correctly use the unit. Keep the manual in an easy-to-find place for anytime reference.
IMPORTANT DISCLAIMER NOTE ABOUT DRINKING IONIZED WATER: Disclaimer: · AMS 2000 Water Ionizer is a water purification product. · Please ensure correct usage of this product and that you have read the instructions fully. · If you feel you are experiencing adverse effects and pain persists, please consult a health care professional.
Page 4
AMS 2000 SAFETY INSTRUCTIONS ① For Electrical Safety When the unit is immersed in water, pull out the power plug immediately and then take the unit out of the water. Avoid an electric circuit overload an outlet or electric wiring.
Page 5
AMS 2000 SAFETY INSTRUCTIONS ③ Operational Safety Guidelines: Do not disassemble, repair and/or modify the unit. ▶ Personal safety could be compromised. ▶ For repair, please contact the authorized sales agent or the authorized service man. Use only sanitary and drinkable water.
Page 6
AMS 2000 SAFETY INSTRUCTIONS ④ Summary ·Do not pull or tug the power cord to prevent safety hazards or damage to the unit. ·Keep the unit in a cool and dry condition. ·Keep the unit clean away from dusts, hot temperature, sunlight, salts, chemicals, etc.
AMS 2000 PACKEAGE CONTENTS One-touch Fitting Safety Key pH Test Reagent / Test Container / Colorimetric Chart Acidic Water Outlet Hose Fuse Screws and holders Water Diverter Source Water Inlet Hose Check Valve Water Outlet Dispenser Cover ※ Accessories are subject to change depending on the product specifications.
AMS 2000 APPEARANCE AND FUNCTIONS FRONT: 1. Front Panel 2. Alkaline Water Outlet Dispenser 3. LCD Screen (Function Indicator) 4. Operation Knob(Water Supply Control Valve) 5. Push Buttons BACK: 6. Main Power Switch 7. Fuse Holder 8. Filter Cover 9. Filter Connection Terminal →...
Page 9
AMS 2000 APPEARANCE AND FUNCTIONS LCD SCREEN (Function Indicator Window): 1. Filter Life 8. Acidic Water Choice Indicator → Replace filter when it flickers. → Indicates the acidic water setting. 2. Authentic Filter Recognizer 9. Purified Water Choice Indicator → Identifies the filter authenticity.
Page 10
AMS 2000 INSTALLATION VIEW OF AN INSTALLED UNIT Alkaline Water comes out Main Body Acidic Water comes out WALL - MOUNT INSTALLATION Vertically attach the provided installation guide paper on the intended position on the wall after slightly pasting the guide paper with water.
AMS 2000 INSTALLATION INSTALLATION PROCEDURE: 1. Select a solid flat surface with proximity to a power supply for desired location. 2. Connect the provided 1/4" hose to water inlet port firmly 1) In case of one touch fitting type, have Water Inlet Port nozzle put into the hose hole completely (fasten the safety key thereon after making connection).
Page 12
AMS 2000 INSTALLATION USAGE OF THE ALKALINE WATER OUTLET DISPENSER: The Alkaline Water Outlet dispenser on the top of the unit is a fold-down type. Handle the dispenser as per the following diagram. Lift the dispenser arm upward to the height of the unit to have it positioned horizontally.
Page 13
AMS 2000 INSTALLATION Have the dispenser positioned in the intended direction. It can be horizontally rotated. USAGE OF THE ALKALINE WATER OUTLET DISPENSER COVER: Push and attach the dispenser cover onto the position as shown in the picture below. ▶ When the unit is not in regular use, have the underneath face of the alkaline water outlet dispenser covered by the cover.
AMS 2000 OPERATION TO START OPERATION: � Plug in AC Power plug firmly into the power supply socket. � Turn on Main Power Switch on the right side ▶ The unit will beep and LCD screen will display standby status.
Page 15
AMS 2000 OPERATION DISPENSING ALKALINE IONIZED WATER: � Rotate Operation Knob clockwise so that the water flows into the unit. � Press “Alkaline Water” Button and choose the pH level by pressing the button repeatedly. ▶ Alkaline water comes out from the Water Outlet Dispenser and acidic water comes out from the lower Water Outlet Hose.
Page 16
AMS 2000 OPERATION DISPENSING ACIDIC IONIZED WATER: � Rotate Operation Knob clockwise so that the water flows into the unit. ▶ Alkaline water setting appears on LCD screen. � Press “Acidic Water” Button and choose the pH level by pressing the button repeatedly.
Page 17
AMS 2000 OPERATION DISPENSING PURIFIED WATER: � Rotate Operation Knob clockwise so that the water flows into the unit. ▶ Alkaline water setting appears on LCD screen. � Press “Purified Water” Button for purified water. ▶ The unit gives the "Purified Water" voice guide.
Page 18
AMS 2000 OPERATION MELODY-ON/OFF: � Just press “Melody” Button to turn the melody sound on or off. ▶ Push “Melody” Button, and the melody sound will be mute. ▶ Push “Melody” Button once again, and the melody sound turns on with appearance of a melody icon on LCD Screen.
AMS 2000 FILTER REPLACEMENT FILTER REPLACEMENT: Replace the filter when Filter Lifespan Indicator flickers. It is the filter replacement timing when the icon flickers. The icon starts flickering when 3% of the full filter life remains available ▶ When a filter life is over, Filter Life icon filckers and there is a voice guide, "please replace with a new fliter".
Page 20
AMS 2000 FILTER REPLACEMENT Insert a new authorized filter 1. Insert a new filter 2. Push the filter down 3. Connect Filter cartridge. and then drag Filter Connection Terminal. Handle to the right. Filter Handle ※ Water may leak from the filter connection points when O-ring is damaged or removed.
Page 21
AMS 2000 FILTER REPLACEMENT Please consider filter replacement with a new one even if the Filter Life Indicator is not indicating the empty Filter Life filter life ( ), in the event of the following abnormal conditions: ▶ Noticeable decrease in water outflow from the unit or a strange smell from water output.
AMS 2000 pH VALUE TEST COMPARATIVE pH TEST · Fill 2/3 of each provided test tube or a glass container with alkaline ionized water, acidic ionized water and tap (municipal) water respectively. Alkaline Tap Water Acidic Water Water · After dripping up to five drops of pH test reagent into each tube, and then shake the tube or container properly to mix well.
AMS 2000 TROUBLESHOOTING Abnormal condition Cause Treatment ·Insufficient water inflow. ·Increase water inflow. ·Power plug is not properly ·Ensure that power plug is plugged in plugged in. correctly. LCD screen does not come on. ·The fuse is blown. ·Replace the fuse.
Page 25
AMS 2000 TROUBLESHOOTING Abnormal condition Cause Treatment ·Filter lifespan is expired. ·Filter lifespan is extremely ·Filter replacement is needed. shortened as poor quality water is used. Dispensed water has a strange smell. ·Due to sudden change of source ·Select pH level 1~2.
AMS 2000 UNIT SPECIFICATIONS UNIT SPECIFICATIONS Product Manufacture Permission No. No.2670 by KFDA Product Classification Alkaline Ionized Water Generator Model AMS 2000 AC 230V / 50Hz Input Voltage (Different voltage and Hz is available as per user’s request.) Power Consumption Net Weight Approx.
AMS 2000 WARRANTY CARD WARRANTY CARD Product Model No. AMS 2000 Name Purchasing Serial No Date ☎ Shop name Seller Address ☎ Name Buyer Address This product passed inspection under strict quality control. If the product has any production defects or any mechanical malfunctions...
Page 28
Please note that a little water may come from the water outlet hoses when a unit is installed. Such water used for quality test at the factory may remain inside of the unit. Producer : ALKAMEDI CO., LTD. Address : Megavalley 601, 602-ho, 268, Hagui-ro, Dongan-gu, Anyang-si, Gyeonggi-do 431-767, Rep. of Korea...