Owner's Manual
DECORATIVE VENTED GAS LOG SET (Electric Ignition)
General Assembly, Installation, and Operation Instructions
ATTENTION! READ INSTRUCTIONS CAREFULLY BEFORE ASSEMBLY OR USE
Models; RF-LD 30/36, 42/48, 60/72 – VEI-Natural Gas (-N) or Propane (-P)
18"
Manzanita, LoneStar, CrossFire, Prestige Oak, Birch, Frosted Oak.
20"/21" Evening Prestige, Evening Desire, Evening CrossFire, Evening Campfire, Evening LoneStar, CrossFire and
TimberFire
24"
Frosted Oak, Birch, Prestige Oak, CrossFire, LoneStar, Manzanita, TimberFire, Evening Lone Star, Evening
Prestige, Evening Desire, Evening CrossFire, Evening Campfire.
30"
Frosted Oak, Birch, Prestige Oak, CrossFire, LoneStar, Manzanita, TimberFire, Evening Lone Star, Evening
Prestige, Evening Desire, Evening CrossFire, Evening Campfire.
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result caus-
ing property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
Installation must be performed by a licensed plumber or gas fitter.
The chimney flue damper, when used with gas logs, will be welded open or completely removed.
A CO detector shall be installed in the room where the appliance is installed.
This is a vented gas appliance for use only in a solid-fuel burning fireplace constructed on non-combustible material
with a fully functional chimney flue which must vent all of the products of combustion.
WHEN OPERATING, THE CHIMNEY DAMPER MUST BE FULLY OPEN
The minimum permanent free opening of the fireplace chimney or chimney damper must be at least the minimum
chimney area shown on the chart on page 6, based on a minimum chimney height of at least 8 feet. The area of the flue
must not be less than 1/10 the area of the fireplace opening. The flue must exhaust all products of combustion.
WARNING: Failure to position the parts in accordance with the diagrams in this manual or failure to use only
parts specifically approved with this appliance may result in property damage or personal injury.
The installation and the provisions for combustion and ventilation air must conform with The National Fuel Gas
Code ANSI Z223.1 / NFPA54, or The CSA B149.1, Natural Gas and Propane Installation Code, latest edition.
RF-LD Multi-Burner
WHITTIER, CA CALIFORNIA 90601 U.S.A.
In the Commonwealth of Massachusetts:
WARNING
MINIMUM FIREPLACE FLUE REQUIREMENTS
1
12028 E. PHILADELPHIA ST.
www.rasmussen.biz
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference .
Improper installation, alteration, service or
maintenance can cause property damage, personal
injury or loss of life. Read these instructions
thoroughly before installation. For assistance or
additional information, consult your gas log dealer,
qualified installer, service agency or gas supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with type of gas
indicated on the rating plate.
Installation must conform with local codes or, in the
absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1/NFPA 54.
Report #10-40
REV RFLD.
Last Printed. 9/9/2020 8:52 AM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RF-RF-LD30/36-VEI-N/P and is the answer not in the manual?

Questions and answers

Summary of Contents for Rasmussen RF-RF-LD30/36-VEI-N/P

  • Page 1 General Assembly, Installation, and Operation Instructions Report #10-40 12028 E. PHILADELPHIA ST. WHITTIER, CA CALIFORNIA 90601 U.S.A. www.rasmussen.biz REV RFLD. Last Printed. 9/9/2020 8:52 AM ATTENTION! READ INSTRUCTIONS CAREFULLY BEFORE ASSEMBLY OR USE Models; RF-LD 30/36, 42/48, 60/72 – VEI-Natural Gas (-N) or Propane (-P) 18”...
  • Page 2 IMPORTANT INFORMATION Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies. • Children and adults should be alerted to the hazard of high surface temperatures and should stay away to avoid burns or •...
  • Page 3: Parts List

    PARTS LIST REQUIRED TOOLS AND MATERIALS Adjustable Wrench and Pipe Wrench. Pipe Sealing compound is required if fittings not already pre-threaded with Teflon tape to prevent gas leaks. DO NOT use Teflon tape or pipe compound on other tapered fittings. Burner Grate Assembley (RF-LD60//72, 10.
  • Page 4 PARTS LIST (Cont’d) 22. GV60 Electronic Ignition Gas Valve (GV60-VNG(Natural gas) (GV60-VLP(Propane) 27. nterruptor Receiver Cable (GV60-RCA) 23. Remote / Transmitter, Variable Height Control (GV60-TXB) 28. On / Off Switch Cable (GV60-SWA) 24. Module / Receiver(GV60-RXA) 8 Wire Cable (GV60-C8) 25.
  • Page 5: General Installation Instructions

    GENERAL INSTALLATION INSTRUCTIONS WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. The appliance and it’s appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi.
  • Page 6 RF-LD MULTIBURNER INSTALLATION AND GAS SUPPLY CONNECTION STEP TWO: BURNER INSTALLATION AND GAS SUPPLY CONNECTION 1. Place Burner-Grate Assembly inside the firebox, centered from left to right, within 1” to 2” of rear wall (Figure 3A). 2. Insure that the Gas Supply to the Fireplace is turned off. Verify correct gas type and proper gas pressures. 3.
  • Page 7 PAN MEDIUM (Amount supplied will vary with each size and style of burner) STEP ONE: Completely cover Burner Pipes (Figure 4A and Figure 5A) and Ember Booster (Figure 4B and Figure 5B) with Pan Medium starting from rear of burner pan and moving toward leading edge. Use entire contents of bag provided, allowing medium to spill over leading edge of burner pan (Figure 4C and Figure 5C).
  • Page 8: Log Placement

    LOG PLACEMENT CAUTION: Crowded logs will cause poor combustion and result in excessive soot formation. The largest logs will be the Front as shown in figures 7A, 8A and 9A and Rear Logs will cross from front log to Rear truss.
  • Page 9 PLACEMENT OF REMOTE RECEIVER FIGURE 10 RF-LD 60/72-VEI-Propane Model below prior to log placement Embers spread over Black Volcanic Ash in burner pan Black Volcanic used to help conceal Flex Black Volcanic Ash used for floor dressing FIGURE 11 Natural Gas Model shown below and How to position Battery Pack outside the fireplace. BATTERY PACK PLACEMENT Battery Pack Battery Pack...
  • Page 10 DO NOT connect to 115 volt line. Safety controls damaged by overheating (not following instruction manual) or 115 volt electricity are not covered by warranty. Rasmussen Iron Works, Inc. can provide a plug in Adapter for AC power supply. We recommend that before you installed the log set you familiarize yourself with the control valve layout and operation “VEI”...
  • Page 11 Batteries required: Handset: 1 by 9V (quality alkaline recommended alkaline recommended) Setting the electronics code NOTE: Remote will be programmed at Rasmussen Gas Logs. Module / Receiver Reset Button (The receiver has to learn the code of the handset) •...
  • Page 12 LIGHTING AND OPERATION WITH REMOTE / TRANSMITTER FLAME HEIGHT ADJUSTMENT USING REMOTE / TRANSMITTER (Picture of transmitter with manual mode display on screen) Large Flame Button • In standby mode: Press and hold (large flame) button to increase flame height •...
  • Page 13 PILOT ADJUSTMENT AND IMPORTANT INSTALLATION INSTRUCTIONS PILOT FLAME ADJUSTMENT: If adjustment is necessary, use a narrow long stem screw driver to turn pilot adjustment screw. To adjust turn clockwise for less pilot flame, counterclockwise for more pilot flame. 1. The adjustment screw can be reached through the small hole in the VALVE knob.
  • Page 14: Normal Operating Characteristics

    Use compressed air and/or a soft bristle brush to clean the air mixer area. Air mixers should not be altered from factory settings. Do not operate this set with any burner objects other than the RASMUSSEN Gas Logs specifically designed and •...
  • Page 15: Troubleshooting

    Parts can be ordered through the supplier from whom you purchased your RF-LD Multiburner and Log Set or from Rasmussen Iron Works, Inc. When ordering parts, please specify; 1. Model number and Serial number of the Burner (available on the Rating Plate).
  • Page 16 Gas Log with the flue blocked or closed will cause fumes and smoke to remain in the room and cause health hazards. DAMPER MUST BE FULLY OPEN WHEN BURNING A GAS LOG SET. CONSUMER RECORD CARD Please record and retain information for future reference. Register your product at www.rasmussen.biz LOG MODEL: SAFETY CONTROL: ®...