Atec HERMES User Manual

Cw transmitter

Advertisement

Quick Links

CW Transmitter
User Manual
CBRS, LTE, 2G, 3G, 4G, 5G, WIFI, Wi-MAX, Public-
Safety, Tetra & LMR
1 Gatehall Dr, Suite 202
Parsippany, NJ 07054
p. (678) 871-2129
f. (413) 604-7537
inquiries@atecwireless.com
www.atecwireless.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HERMES and is the answer not in the manual?

Questions and answers

Summary of Contents for Atec HERMES

  • Page 1 CW Transmitter User Manual CBRS, LTE, 2G, 3G, 4G, 5G, WIFI, Wi-MAX, Public- Safety, Tetra & LMR 1 Gatehall Dr, Suite 202 p. (678) 871-2129 inquiries@atecwireless.com Parsippany, NJ 07054 f. (413) 604-7537 www.atecwireless.com...
  • Page 2 This document contains proprietary information that is protected by copyright; it is intended for use by ATEC Wireless and its customers only. No part of this manual may be produced or transmitted in any form or by any means without prior written consent of ATEC Wireless Trademarks ATEC Wireless is a trademark of Atlanta Trading &...
  • Page 3: Table Of Contents

    Table of Contents Executive Summary ....................3 Purpose Overview Key Features Safety Compliances ....................4 Equipment Unpacking & Parts ................5 III. Parts IV. Main Interface ....................... 6 Upper Interface ..................... 7 VI. Screen Display ....................... 8 VII. General Display ..................... 9 Preparations Menus Channels...
  • Page 4: Executive Summary

    (CW) signals for network testing. 2. Overview ATEC's test transmitter is a device that generates a CW (Continuous Wave) signal with maximum output power +20 dBm. It is compact, portable, lightweight and easy to use for indoor and outdoor (with an amplifier) coverage test scenarios.
  • Page 5: Safety Compliances

    • Best practice is to connect the antenna before turning-on the RF Power. • Do not operate near flammable or explosive materials. • If you suspect there is damage to this product, have it inspected only by authorized service personnel or service centers. HERMES CW TRANSMITTER USER MANUAL - NOVEMBER 2021...
  • Page 6: Equipment Unpacking & Parts

    -USB user Manual CW Transmitter. Charger cable. Note: we recommend using the original Cable and charger adapter, but other types could be used as long as they meet the voltage/ amperage parameters. HERMES CW TRANSMITTER USER MANUAL - NOVEMBER 2021...
  • Page 7: Main Interface

    Navigation through menu/rows button i) Power ON/OFF: Toggle Device Power (Long press) j) SHIFT: Function Shift Button k) # sign is also ( - ) negative sign l) Battery capacity level Indicator HERMES CW TRANSMITTER USER MANUAL - NOVEMBER 2021...
  • Page 8: Upper Interface

    LED: Battery Fully Charged. (Remove charging cable after red LED turns ON) Flashing red LED: Charging problem or battery problem. C – Solid blue LED: USB Charger is Connected to the device. HERMES CW TRANSMITTER USER MANUAL - NOVEMBER 2021...
  • Page 9: Screen Display

    VI. Screen Display a) Channels Menu b) SETTINGS Menu c) Analytics / Charts (Future release) d) PROJECTS Menu e) HELP Menu HERMES CW TRANSMITTER USER MANUAL - NOVEMBER 2021...
  • Page 10: General Display

    ENTER to type and enter again to change to other cell. After all ports are set, press run and wait for the selected ports turn green. HERMES CW TRANSMITTER USER MANUAL - NOVEMBER 2021...
  • Page 11 You may activate all RF ports by pressing F1, deactivate all RF ports by pressing F2 or select individual ports to switch ON or OFF. To select an individual port, navigate through the arrows to the desired port and press ENTER to toggle between ON and HERMES CW TRANSMITTER USER MANUAL - NOVEMBER 2021...
  • Page 12: Settings

    For Modules info, press 2 on keypad For calibration history and upcoming calibrations, press 3 on keypad. For keypad settings, press 4 on keypad. Press “F4” or “ESC” anytime, to go back to main Menu HERMES CW TRANSMITTER USER MANUAL - NOVEMBER 2021...
  • Page 13: Help

    5. Modular RF Boards • The RF modules are independent and modular-set boards driving each output port. This allows: • Better maintenance procedures • Independent signal drivers • Better PIM specs • Better power management HERMES CW TRANSMITTER USER MANUAL - NOVEMBER 2021...
  • Page 14: Tft Lcd Screen

    7. User Interface Multi-function keypad and LCD screen has been adapted to allow faster operation HERMES CW TRANSMITTER USER MANUAL - NOVEMBER 2021...
  • Page 15: Spec Table

    > 2.5 hours at 6 ports on Physical External Dimensions L7.87 x W6.75 x H1.87 in Overall weight 2.44lb / 1106g Operating Temp -10 to +45 C / -14 to+ 113 Screen 3.5" Color TFT (VGA) HERMES CW TRANSMITTER USER MANUAL - NOVEMBER 2021...
  • Page 16: Max Power Levels

    200 MHz 400 MHz 800 MHz 900 MHz 1400 MHz 1500 MHz 1700 MHz 1800 MHz 1900 MHz 2100 MHz 2300 MHz 2600 MHz 2700 MHz 2800 MHz 3000 MHz 4000 MHZ HERMES CW TRANSMITTER USER MANUAL - NOVEMBER 2021...
  • Page 17: Contact Support

    1. Technical Support, Calibrations & Post Sales Assistance: For any support inquiry, contact: Support@atecwireless.com 2. General Queries: For any information about prices, specifications, future developments, recommendations, customizations, or general question, kindly contact sales: sales@atecwireless.com HERMES CW TRANSMITTER USER MANUAL - NOVEMBER 2021...

Table of Contents