Page 1
DRPTAC07Y32351A, DRPTAC09Y32351A, DRPTAC12Y32351A, DRPTAC15Y32351A, DRPTAC15Y32501A, DRPTHP07Y32351A, DRPTHP09Y32351A, DRPTHP12Y32351A, DRPTHP15Y32351A, DRPTHP15Y32501A Model Number: Serial Number: Purchase Date: Installing Contractor Company Name: Capture relevant information about your Durastar PTAC equipment before it is installed and write it above for future reference. DURASTAR.COM...
• Read the troubleshooting section of this manual as it will help you diagnose and solve common issues. • Visit us on the web at www.durastar.com to download product guides and up-to-date information. • If you need warranty service, our friendly customer service representatives are available via email at questions@durastar.com or by telephone at 1-888-320-0706.
Otherwise, you may experience personal injury or damage to the air conditioner and surrounding property. Please contact a qualified service representative when you need to repair the air conditioner. • Do not block the air outlet or air inlet. This could cause a malfunction. DURASTAR.COM...
Page 5
For all electrical work, follow all local and national wiring standards and regulations. Connect cables tightly, and clamp them securely to prevent external forces from damaging the terminal. Improper electrical connections can overheat and cause fire, and may also cause shock. DURASTAR.COM...
Page 6
• The power supply cord must be replaced if it fails reset when either the TEST button is pushed or it cannot be reset. A new one can be obtained from Durastar. • If the power supply cord is damaged, it cannot be repaired. It MUST be replaced by one obtained from Durastar.
Temperature (18°C - 43°C) (-5°C - 24°C) To further optimize the performance of your unit, do the following: • Keep doors and windows closed. • Do not block air inlets or outlets. • Regularly inspect and clean air filters. DURASTAR.COM...
THIS UNIT IS CONTROLLED BY THERMOSTAT INSTALLATION ACCESSORIES The following installation accessories can be purchased separately. • Wall Sleeve Assembly • Rear Grille • Drain Kit TOOLS NEEDED The following tools are required for installation. • Phillips screwdriver • Level • Wire cutters (optional) DURASTAR.COM...
(CON) or cycling (CYC) fan, low temperature protection, wall thermostat control, and front desk control. See the Dip Switch Configuration and Wall Thermostat Terminal sections for more details. This unit has many features the servicer should be familiar with in order to properly service the unit. DURASTAR.COM...
UP/DOWN ( + / - ) Push the UP (+) or DOWN (-) button to increase or decrease the temperature setpoint by increments of 1°F (1°C) in COOL or HEAT mode. The set temperature will appear in the display. DURASTAR.COM...
Page 11
LO- Room temperature is lower than 32°F (0°C) HI- Room temperature is higher than 99°F (37°C) FP- Low Temperature Protection NOTE When an error occurs, unplug the unit for one (1) minute and plug it back in. If error repeats, call for service. DURASTAR.COM...
INTAKE OVER 20” WALL in (606mm) STEP 1: Carefully remove the shipping tape from the front panel. Shipping tape STEP 2: Remove the front panel. Then lift up Pull out at the bottom to release it from the tabs. DURASTAR.COM...
Page 13
Secure the unit with the four (4) screws and washers, supplied with the SLEEVE ASSEMBLY (purchased separately), through the corner holes that bracket the unit. STEP 5: Reinstall the front panel. Place tabs over top rail Push inward at bottom until panel snaps into place DURASTAR.COM...
See the following diagram and table for the configuration and function of each Dip Switch position. Carefully adjust the Dip Switch positions to the desired configuration settings. When you have finished, replace the front panel. The settings will be activated when you turn the unit back on. DURASTAR.COM...
Page 15
• CYC (CYCLE): This setting allows the fan to cycle on and off with the compressor or electric heater. The fan stops a short time after the temperature setting is satisfied. NOTE In HEAT mode, the set temperature does not go higher than 84°F (29°C). DURASTAR.COM...
30 seconds will exit the dip switch configuration by control panel and the unit will save the last settings. To activate Front Desk Control, the "A0" setting must be selected and the "SW7" dip switch must be in the DOWN (OFF) position. DURASTAR.COM...
High fan speed 4-WAY 4-way valve; Reverse cycle (Energized in Heat) For heat pump models HEAT 2 Electrical heater 2 HEAT 1 Electrical heater 1 COMP Compressor 24V (N) 24VAC terminal N (Neutral), Common 24V (L) 24VAC terminal L (Line) DURASTAR.COM...
Page 18
The setpoint temperature range of the thermostat must match the setpoint temperature range of the unit. • The type of thermostat must match the unit type: PTHP (heat pump) or PTAC (no heat pump). • Do not remove the control panel. DURASTAR.COM...
Page 19
24VAC signal, it will run as normal. When the signal stops, the unit will turn off. To activate this feature, the Front Desk Control dip switch shown below must be in the DOWN (OFF) position. Dip switch of FRONT DESK CONTROL DURASTAR.COM...
Clean inside and outside of the outdoor coils regularly. NOTE • Never use a high-pressure spray to clean any part of the unit. • Never use a hair/clothes dryer or other means to speed up drying. DURASTAR.COM...
Page 21
4. Clean the filter and dry thoroughly before replacing. 5. Replace filter and vent door by reinstalling the four (4) screws to the filter and reconnecting the steel wire to the top of the vent door. Vent door control lever Vent door steel wire Screws Vent door DURASTAR.COM...
3 minutes and a minimum compressor run time of 3 minutes. ELECTRIC Evaporator coil is Check the evaporator coil regularly. Have the HEATING dirty or clogged. evaporator coil cleaned by a professional technician FAILURE once every three (3) months. DURASTAR.COM...
Page 23
If circuit breaker is tripped or fuse is blown more than once, contact a qualified electrician. • If unit is installed where condensation drainage could drip in an undesirable location, an accessory drain kit should be installed and connected to drain system. DURASTAR.COM...
For a period of ONE (1) YEAR from the date of original retail purchase, Durastar will repair or replace, free of charge (including labor), any Product or parts that fail due to a defect in materials or workmanship.
Page 26
If on- site service is not available, Durastar may, at its option, arrange to transport the Product to and from a Durastar authorized service center. Durastar is not responsible for unit removal, replacement, or relocation of the unit if it is inaccessible or cannot be repaired on-site.
TRANSPORT OF EQUIPMENT CONTAINING FLAMMABLE REFRIGERANTS See transport regulations. MARKING OF EQUIPMENT USING SIGNS See local regulations. DISPOSAL OF EQUIPMENT USING FLAMMABLE REFRIGERANTS See national regulations. STORAGE OF EQUIPMENT/APPLIANCES The storage of equipment should be in accordance with the manufacturer's instructions DURASTAR.COM...
Page 28
Refrigerating pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components, unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded. DURASTAR.COM...
Page 29
(25 % maximum) is confirmed. Leak detection fluids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe-work. DURASTAR.COM...
Page 30
Make sure that cylinder is situated on the scales before recovery takes place. • Start the recovery machine and operate in accordance with instructions. • Do not overfill cylinders. (No more than 80 % volume liquid charge). • Do not exceed the maximum working pressure of the cylinder, even temporarily. DURASTAR.COM...