Vega Technologies CN-01MD Instruction Manual

Compressor nebulizer

Advertisement

Quick Links

VEGA TECHNOLOGIES INC.
INSTRUCTION MANUAL
Compressor nebulizer
Model No: CN-01MD
File Number: CN-01MD-SPC001
Version/Revision No: 1.0
Date: November 01, 2022
1 / 23

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CN-01MD and is the answer not in the manual?

Questions and answers

Summary of Contents for Vega Technologies CN-01MD

  • Page 1 VEGA TECHNOLOGIES INC. INSTRUCTION MANUAL Compressor nebulizer Model No: CN-01MD File Number: CN-01MD-SPC001 Version/Revision No: 1.0 Date: November 01, 2022 1 / 23...
  • Page 2: Table Of Contents

    (Read this instruction manual carefully before use) Contents Introduction ..........................3 Safety precaution ........................6 Information for operation ......................9 Cleaning and maintenance ....................10 Troubleshooting information....................12 Service information ........................12 Technical specifications ......................14 Symbols ............................15 Disposal ............................16 10.
  • Page 3: Introduction

    1. Introduction Thank you for purchasing the compressor nebulizer. It is a compact medical device designed to efficiently deliver physician prescribed medication to the bronchial lung passages. With proper care and use, it will provide you with many years of reliable treatment.
  • Page 4 Asthma, Bronchiectasis, Bronchiolitis, COPD, Cystic Fibrosis, Intubated patients/those with tracheostomy, Other Obstructive or Interstitial lung diseases, Palliative Indications Care: Symptom relief, Post lung transplant, Pulmonary Hypertension, Respiratory Infection: prevention or control. Contraindications Unconscious or are not breathing spontaneously. Saline solution and medication prescribed by the doctor. Medication restriction This product is intended for use in a medical facility, such...
  • Page 5 1.3. List for devices intended to be used in combination Combination devices Specification Model Nebulizer Bottle CNK-M03 Air Tube CNK-S01 PVC, 150cm Mouthpiece CNK-M06 Nosepiece CUK-M04 translucent Air Filters CNK-S03 Adult Mask PVC, transparent, CUK-M01 with mask strap Child Mask PVC, transparent, CUK-M02...
  • Page 6: Safety Precaution

    2. Safety precaution Read all the information in the instruction manual and any other literature included in the box before using the device. When using an electrical product, especially when children are present, basic safety precautions should always be followed including the following: Warning: Indicates a potentially hazardous situation which, if not avoided, could result in serious injury.
  • Page 7 14) Do not use the device while sleeping or sleepy. 15) Do not use in anesthetic or ventilator breathing circuits. 16) Store the device and combination devices in a clean location. 17) Do not store the air tube while there is moisture or medication remaining inside 18) Do not use the device where it may be exposed to flammable gas.
  • Page 8 5) Do not leave the device unattended with infants or person who cannot express their consent. 6) When using the device, the main unit may become hot. 7) Do not touch the main unit for other than necessary operation such as turning off the power while nebulizing.
  • Page 9: Information For Operation

    3. Information for operation 3.1. Functional description Atomizing inhalation is an important and effective treatment method for the treatment of respiratory diseases. The drug solution is atomized into small particles by means of atomizing inhaler, and the drug enters the respiratory tract and lung deposition by means of breathing inhalation, so as to achieve the objective of painless, rapid and effective the treatment.
  • Page 10: Cleaning And Maintenance

    7) Attach the other end of air tube to the tube connector located on the front of the compressor. 8) Attach mouthpiece or mask per your choice to the top section of nebulizer bottle. 9) Plug the power cord into an appropriate electrical outlet. Make sure at this stage, the power switch is at “OFF”...
  • Page 11 3) Rinse the nebulizer bottle, mask and other optional combination devices with clean water. 4) Dry the nebulizer bottle, mask and other optional combination devices with a soft clean cloth, or dry them naturally. (Note: Do not damage or lose the small cone of nebulizer bottle when clean that part.) 5) Reassemble the nebulizer bottle after it is completely dry, then disinfect the product.
  • Page 12: Troubleshooting Information

    Maximum cleaning disinfection and use times According to Cleaning and Disinfection Cycles Test Report, 2190 times. 5. Troubleshooting information Check the following if your unit should fail during operation. You can also refer to the pages of this manual for complete instructions. Problem Cause Remedy...
  • Page 13 purchase date. This warranty does not extend to non-durable components which are subject to normal wear and need periodic replacement. Any abuse, operation other than the intended use of this product as outlined in the manual, negligence, accident, or repairs by someone other than a VEGA’s Authorized Service Professional, shall immediately void this warranty.
  • Page 14: Technical Specifications

    7. Technical specifications 7.1. Specifications table Product name Compressor nebulizer Model CN-01MD Type BF Applied part Mouthpiece Adult/child mask Power (main unit) 230V/50Hz Mode of operation Non-continuous (30 Min. on / 30 Min. off) The typical operation time 30 min.
  • Page 15: Symbols

    7.2. The particle size distribution curve 8. Symbols 8.1. Symbols and description Refer to instruction Manufacturer manual/booklet Batch code Date of manufacture Serial number Caution 15 / 23...
  • Page 16: Disposal

    Type BF applied part Temperature limitation Keep away from sunlight Protection class II IP21 Humidity limitation Ingress protection Direct current Keep away from rain "ON"/"OFF" (push-push) Alternating current This device complies with the requirements of Quantity 0123 Regulation (EU) 745/2017 Authorized This way up representative...
  • Page 17: Information About Electromagnetic Compatibility

    materials. Consider the country-specific laws and regulations that apply to the disposal of the device. The proper disposal of the device prevents environmental and human damage. Outside the EU, the appropriate national regulations for disposal must be observed. 10. Information about Electromagnetic Compatibility Medical Electrical Equipment needs special precautions regarding Electromagnetic Compatibility (EMC).
  • Page 18 RF emissions CISPR 11 Class B The device is suitable for use in all establishments other than domestic Harmonic emissions Not applicable and those directly connected to the IEC 61000-3-2 public low-voltage power supply Voltage fluctuations network that supplies buildings used for flicker emissions domestic purposes.
  • Page 19 Surge ± 1 kV line(s) Not applicable Mains power quality should be that of a typical commercial or hospital environment. line(s) IEC 61000-4-5 ± 2 kV line(s) to earth Voltage dips, <5 % UT Not applicable Mains power quality should be short that of a typical commercial or (>95 % dip in...
  • Page 20 (50/60 Hz) environment. magnetic field IEC 61000-4-8 NOTE UT is the a.c. mains voltage prior to application of the test level. Table 3 Guidance and manufacturer’s declaration – electromagnetic immunity The device is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment.
  • Page 21 80MHz should be less than the compliance level in each frequency range. Interference may occur in the 2.5GHz vicinity of equipment marked with the following 61000-4-3 symbol: NOTE 1 At 80MHz and 800MHz, the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
  • Page 22: Contact Information

    The device is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the device can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the device as recommended below, according to the maximum output power of the communications equipment.
  • Page 23 Vega Technologies Inc. No.505, Shengping Mid.Road, Yangwu, Dalang Town, 523789 Dongguan City, Guangdong Province, PEOPLE'S REPUBLIC OF CHINA Website: www.vegamedical.com MedPath GmbH Mies-van-der-Rohe-Strasse 8, 80807 Munich, Germany 0123 Made by: Approved by: 23 / 23...

Table of Contents