  • Page 1 OPER ATING MANUAL...
  • Page 3 Dear customer! The TS-100 is the latest automotive digital measuring device from AUTHOR ALARM. Intended for professional use by automotive electronics experts. The TS-100 will become an indispensable assistant when installing additional equipment, troubleshooting and diagnosing electrical equipment of modern cars. Equipped with digital data buses, such as CAN, LIN, K-line, etc, the tester has a 3.7V built-in...
  • Page 4: Table Of Contents

    TABLE OF CONTENT S DESCRIP TION OF THE DE VICE ........2 BEGINNING OF WORK ..........3 Turn on / off the device ............3 Menu navigation and mode selection ........ 3 Using the device ................4 Charging the battery of the device ........4 Software Update .................
  • Page 5: Descrip Tion Of The De Vice

    DESCRIP TION OF THE DE VICE 1. Menu Button «on / off» device button «go to modes», button «exit from the selected mode». 2. OK Button «enter the mode». And also with prolonged by pressing the «on / off» button work area backlight mode (if the device included).
  • Page 6: Beginning Of Work

    11. Illumination of the working area. 12. Cable with clip 13. Clamp 14. Jack 3.5 mm plug for wire connection with the clamp to tester BEGINNING OF WORK Turn on / off the device Turn on the device by pressing and holding the MENU button «No.
  • Page 7: Using The Device

    Using the device After selecting the required operating mode, it is necessary to connect a cable with a clip «No. 12» to the connector on the device «No. 8» using a plug «No. 14». Cable connection field is required to connect the clamp «No.
  • Page 8: Oper Ating Modes

    OPER ATING MODES VOLTAGE (Voltage Measurement Mode) This mode is intended for level measurement. tension and the search for «ground «. Voltage values circuits are shown in 4-bit form on OLED display «No. 7» and are duplicated by color indication LED indicator «No. 10» and sound Indication by the built-in buzzer.
  • Page 9: Oscil (Oscilloscope Mode)

    To enable simulated continuous pressing buttons «No. 3» or «No. 4» is necessary within 1 second 2 times briefly click on the appropriate button. The simulation mode is turned off pressing a short press on the button «No. 3» or «No. 4». An example of verification is shown in the photo below: Value voltage 13.53V corresponds to the voltage before applying the load, 13.12V corresponds to the value after...
  • Page 10: Detect (Digital Bus Detection Mode Data Transmission)

    For convenience, you can view the signal diagram expand or collapse using the buttons «No. 3» and «No. 4» respectively. For detailed waveform analysis Recording mode is provided. Recording mode is activated by a long press of the button «No. 3» or «No. 4», the transition to the recording mode is confirmed by the appearance the REC icon on the OLED display «No.
  • Page 11 When activating the mode on the OLED display «No. 7» read appears. Upon detection of signals in the test bus the tester automatically starts the process identification, the transition to the identification process confirmed by ellipsis after the inscription «read» on the OLED display «No.
  • Page 12: Pulse (Pulse Mode)

    PULSE (Pulse Mode) Pulse mode is intended to output a negative polarity pulse lasting 0.3 sec with an interval of 1 second between pulses. The device and can be used to find the necessary wire in different parts of the car. Turn on and off the pulse carried out with a short press buttons «No.
  • Page 13 When setting the maximum volume of the sound alert sound will change tonality, depending on a voltage level on the test wire is similar to duplication color of the LED indicator «No. 10». By short pressing of the button «No. 3» is configured algorithm for the appearance of sound indication in the mode «VOLTAGE».
  • Page 14: Sof T Ware Update In T S - 100

    SOF T WARE UPDATE IN T S - 100 To update the tester software, need a computer with a network connection internet, USB cable – micro-USB. 1. Download from the service site of the AUTOR company and install the software on the PC «Bootloader_TS-100»...
  • Page 15 6. After detection by the program «Bootloader_TS-100» tester in software update mode ensure the program window becomes active 7. In the top line of the software fi le selection software tester need to click on the button for opening the conductor, and in the opened window specify the path to the software fi le software downloaded to PC (open folder into which you downloaded the fi le and...
  • Page 16 8. In the top line of the software fi le selection the software version is displayed ensure, then you need to press the button «Loading», after which the process will begin tester software updates. 9. Wait until the software download is complete software to the tester.
  • Page 17: Technic Al Cha R Ac Teris Tic S

    Built-in battery capacity ..........350 mA On-time backlight ..............4 h Full charge time of the built-in element power supply ... 5 h COMPLE TENESS Tester TS-100................. 1 PC Cable with clamp ..............1 PC Operating manual ..............1 PC Made in Russia Manufacturer: Author LLC C-RU.АЛ14.В.10098...
  • Page 18: Warr Ant Y Certific Ate

    WARR ANT Y CERTIFIC ATE Warranty period - 12 months from the date of production of the goods. During indicated period free technical support is guaranteed and free repair of goods. Warranty does not apply to cases: • natural wear of consumables and product details, subject to natural wear during operation;...