PMM-810 Digital Multimeter TABLE OF CONTENTS ® PROSTAT PMM-810 DIGITAL MULTIMETER Title Page # Before using the Instrument ................... 3 Safety ..........................3 III. Function .......................... 4 Maintenance........................4 Operation ........................6 Individual PMM-810 Multimeters ..................8 General Specifications ....................10...
PMM-810 Digital Multimeter Before using this, or any other electronic piece of equipment, carefully read the instruction manual completely. Before using the Instrument Examine the instrument for damage, contamination (excessive dirt, grease, etc..) and defects. Examine the test leads for cracked or frayed insulation.
The PMM-810 includes color coded safety input jacks, large 3-1/2 digit LCD display, overload protection on all ranges, Frequency Auto-ranging selection from 20 - 20M Hz, and fused protection for current inputs.
PMM-810 Digital Multimeter The meter is now ready for use. Fuse Replacement If no current measurements are possible, check for a blown overload protection fuse. Turn the power off and remove all the test leads. For access to fuses, use a screwdriver to remove the three screws from the back of the meter.
Page 7
PMM-810 Digital Multimeter Set the Function/Range switch to the desired W resistance range or continuity position. Remove power from the equipment under test. Connect the red test lead to the "V W" jack and the black test lead to the "COM"...
Read the capacitance directly from the display. Individual PMM-810 Multimeters If your PMM-810 Multimeter was purchased individually, (not in a pre-packed auditing kit) it is enclosed by a rubber "boot". On the boot is a handy stand with a strap.
Page 9
® If your PMM-810 was purchased as part of a PROSTAT auditing kit, the PMM-810 Boot ® with stand and strap may be purchased as an option. Contact your PROSTAT representative for information. Stand & Strap Use Handy Stand Pull the stand on the back of the meter boot all the way out.
Page 10
PMM-810 Digital Multimeter Dimensions: 147mm (H) x 70 mm (W) x 39 mm (D) Weight: Approximately 345g (12.2 oz) with Optional "Boot" Accessories: 2 Test Leads, One spare fuse (0.5A/250V Fast Blow) 9V battery installed Operation Environment: C to 50 C at <...
Page 11
Duty: <40% and >60% Overload Protection: 500VDC or AC rms Logic Test Threshold: Logic Hi (2.8 ± 0.8V) Logic Lo (0.8 ± 0.5V) Indication: 40 msec beep at logic low Overload Protection: 500VDC or AC rms Rev: PMM-810 – 08-2001 Format modification: 01-20-2005...
Page 12
Copyright 2001-2007 Prostat Corporation Printed in U.S.A. 1072 Tower Lane, Bensenville, IL 60106 USA www.prostatcorp.com...
Need help?
Do you have a question about the PMM-810 and is the answer not in the manual?
Questions and answers