Aleo evio EM-AC Series Installation Instructions

Led emergency driver

Advertisement

INSTALLATION INSTRUCTIONS

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should always be followed, Including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS:
CAUTION -
DO NOT join battery connector until installation is complete and AC power is supplied to the emergency driver.
DO NOT Use Outdoors. Use with grounded, UL Listed, damp location rated fixtures, case should be grounded.
DO NOT mount near gas or electric heaters.
DO NOT use this equipment for other than intended use
For use in 0ºC minimum, 50ºC maximum ambient temperature. Not for use in heated air outlets and wet or hazardous
locations.
An unswitched AC power source is required (120-277 VAC, 50/60 Hz). The EM-AC and AC driver must be on the same
branch circuit.
The EM-AC should be mounted in locations and at heights where it will not be subjected to tampering by unauthorized
Personnel.
The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
WARNING -
FAILURE TO FOLLOW THESE INSTRUCTIONS AND WARNINGS MAY RESULT IN SERIOUS INJURY
OR DAMAGE TO PROPERTY
For your safety, thoroughly read these instructions and warnings in its entirety prior to installing or servicing this product.
These instructions do not attempt to cover all installation and maintenance circumstances. If you do not understand these
instructions or if additional information is needed, please contact Evio customer service.
WARNING -
This product must be installed and serviced by a professional electrician in accordance with applicable
federal, state, and local laws, regulations, and electrical code. If not qualified, do not attempt installation of this product.
Contact a qualified electrician.
WARNING -
To avoid risk of electrical shock, AC Power must be off before installing or servicing of emergency driver.
Verify that supply voltage is correct by comparing with the input voltage on the driver label
Make all electrical and ground connections in accordance with NEC and any applicable code requirements
CAUTION -
This is a sealed unit. Components are not replaceable. Replace the entire unit when necessary.
CAUTION -
To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp
objects. Do not let power supply wires touch hot surfaces luminaire wiring and electrical parts may be damaged when
drilling for installation of LED Emergency Backup.
CAUTION -
Battery is rechargeable LiFePO4 and must be recycled or disposed of properly.
IMPORTANT -
LED Indicator light illuminated indicates battery is in charge mode when AC power is applied. It is
recommended and required by applicable code to test the emergency driver to ensure proper function of the system; push
the test switch for thirty (30) seconds every 30 days to ensure the emergency driver is functioning as LED light source is
illuminated. Conduct a ninety (90) minute discharge test one (1) time per year; LED light source should be illuminated for
a minimum of ninety (90) minutes
IMPORTANT: THE BATTERY MUST BE RECHARGED EVERY (3) THREE MONTHS. IF NOT RECHARGED
ACCORDINGLY, BATTERY MAY FAIL AND VOID WARRANTY.
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
THIS PRODUCT CONTAINS A RECHARGEABLE LiFePO4 BATTERY. THE BATTERY MUST BE RECYCLED OR
DISPOSED OF PROPERLY.
LiFePO4
Aleo Lighting, Inc. | (877) 358-8825 | www.aleolighting.com
EM-AC Series
LED EMERGENCY DRIVER
MODEL: EM-AC-V200-UNV-H-FI-16
1 of 3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the evio EM-AC Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Aleo evio EM-AC Series

  • Page 1 ACCORDINGLY, BATTERY MAY FAIL AND VOID WARRANTY. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE THIS PRODUCT CONTAINS A RECHARGEABLE LiFePO4 BATTERY. THE BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY. LiFePO4 1 of 3 Aleo Lighting, Inc. | (877) 358-8825 | www.aleolighting.com...
  • Page 2 Insert Test Button (without wall box cover plate) into pre-drilled ½” hole in appropriate location of fixture. Connect Test Button to EM-AC. 2 of 3 Aleo Lighting, Inc. | (877) 358-8825 | www.aleolighting.com...
  • Page 3 The LED load should operate at reduced output Annually – Insure that the Test Button is illuminated. Conduct a full 90-minute discharge test. The unit should operate as intended for the duration of the test. 3 of 3 Aleo Lighting, Inc. | (877) 358-8825 | www.aleolighting.com...

This manual is also suitable for:

Evio em-ac-v200-unv-h-fi-16