Server
Operating Properties
System fan
System fan
System fan
Power Supply
Power Supply
R263-Z35-AAF1
1+1 2400W 80 PLUS Platinum redundant power supplies
AC Input:
- 100-127V~/ 12.5A, 47-63Hz
- 180-200V~/ 14.5A, 47-63Hz
- 200-240V~/ 14.5A, 47-63Hz
DC Input: (Only for China)
- 240Vdc, 12A
DC Output:
- Max 1000W/ 100-127V~
+12V/ 84A
+12Vsb/ 3A
- Max 2200W/ 180-200V~
+12V/ 180A
+12Vsb/ 3A
- Max 2400W/ 200-240V~ or 240Vdc Input
+12V/ 197A
+12Vsb/ 3A
R263-Z35-AAL1
1+1 2700W 80 PLUS Titanium redundant power supplies
AC Input:
- 100-127V~/ 12A, 50-60Hz
- 200-240V~/ 16A, 50-60Hz
DC Input: (Only for China)
- 240Vdc/ 16A
DC Output:
- Max 1008W/ 100-127V~
+12V/ 84A
+12Vsb/ 3A
- Max 2700W/ 200-240V~ or 240Vdc Input
+12V/ 225A
+12Vsb/ 3A
NOTE:
The system power supply requires C19 type power cord
The default power supply is based on a basic system configuration. Please
contact with technical representatives to determine the best power supply
selection for your system configuration requirements and preferred efficiency.
The power supply specifications provided herein is for the default server
configuration. Different SKUs have different PSU specs, so please see the system
rating label on the server for the accurate PSU specification.