HANECO LED DIMMER INSTALLATION GUIDE
Thanks for choosing our DUO
We strongly recommend that you read this manual carefully before installation.
• This product must be installed by a licensed electrician in accordance with all the requirements of AS/NZS 3000 (current edition) and
• Complies to Australian Standards AS 60669.2.1 and AS CISPR 15 (x2 Capacitor IEC 60384-14)
• Dimming circuits and product compatibility must be validated by the installer before installation.
Haneco cannot be responsible for third party changes in dimmer compatibility
• A load correction device – x2 Capacitor type 275Vac, 0.10 F, 40/110/56/B – has been included with your DUO
load is experienced, connect the load correction device in parallel with the connected load of the DUO
Technical Specifications
Operating Temp
0Cº - 50Cº
Thermal Derating
25Cº - 50Cº
(350W - 175W)
MAX DIMMER LOAD
AND MULTI GANG
**Multi Gang
350W I 1
**
Derating
300W I 2
**
250W I 3
**
200W I 4
**
Contents
ENTER SETUP MODE
LONG PRESS 2 SECS
ENABLE/DISABLE BACKLIGHT
2 CLICKS
ENABLE/DISABLE SWITCH
3 CLICKS
SET MINIMUM BRIGHTNESS
4 CLICKS
1. Apply label to grid
2. Attach cover
SET MAXIMUM BRIGHTNESS
5 CLICKS
ON/OFF
1 CLICK
MAXIMUM COMPATIBILITY
6 CLICKS
DIM DOWN OVER 30 MINS 3 CLICKS
OPTIMISED DIMMING
7 CLICKS
DIM UP OVER 30 MINS
4 CLICKS
RESET TO FACTORY SETTINGS
9 CLICKS
This label should be placed on the
main switchboard in a visible area.
CAUTION
This installation contains
solid state devices.
A low reading may be obtained
if megger testing.
Solid state devices are installed
in the following circuits.
*Sticker denotes dimmer location
L1
L2
L3
L4
L1 L2 L3 L4
3
Align the mechanical stop of the
rotary knob toward the LEFT side
of the mechanical stop on the
dimmer housing to prevent further
anti-clockwise adjustment
(or RIGHT side when setting
max brightness level).
For more information
www.haneco.com.au
DUO
G2
LED Floodlight products.
G2
PRODUCT CODE: DUO350WG2
WARNING
other relevant Standards and Regulations
• ENSURE electricity is disconnected prior to installation
• Indoor Use only. Not suitable for damp or explosive environments
• No User serviceable parts inside
Connection Diagram
ONE WAY DIMMING
(ON/OFF ENABLED)
UNSWITCHED ACTIVE
DIMMER
SWITCHED/
DIMMED ACTIVE
LOAD
NEUTRAL
1
After wiring and installation onto
grid plate, remove the rotary knob.
4
Setup
ON/OFF
DIM DOWN OVER 30 MINS
DIM UP OVER 30 MINS
ENTER SETUP MODE
ENABLE/DISABLE BACKLIGHT
ENABLE/DISABLE PUSH SWITCH*
SET MINIMUM BRIGHTNESS / CANCEL
SET MAXIMUM BRIGHTNESS / CANCEL 5 CLICKS
MAXIMUM COMPATIBILITY
OPTIMISED DIMMING
RESET TO FACTORY SETTINGS
* The integrated push switch allows ON/OFF switching of LOAD by a momentary press of rotary knob.
Two way switching is not possible with the integrated push switch.
1300 001 LED
Dimmer. If flickering of the luminaire
G2
dimmer to improve performance.
G2
TWO WAY DIMMING
(ON/OFF DISABLED)
ACTIVE
1
1
C
C
DIMMER
2
2
LOOP
LOOP
SWITCH
SWITCH
2
Turn the dimmer shaft
anti-clockwise until the required
minimum brightness is reached
(or clockwise to set max
brightness level).
1 CLICK
3 CLICKS
4 CLICKS
LONG PRESS 2 SECS
2 CLICKS
3 CLICKS
4 CLICKS
6 CLICKS
7 CLICKS
9 CLICKS
LOAD
NEUTRAL
Last updated 12/02/24

Advertisement

loading

Summary of Contents for Haneco DUOG2

  • Page 1 • Dimming circuits and product compatibility must be validated by the installer before installation. Haneco cannot be responsible for third party changes in dimmer compatibility • A load correction device – x2 Capacitor type 275Vac, 0.10 F, 40/110/56/B – has been included with your DUO Dimmer.
  • Page 2 Confirmation from Haneco: You will receive a confirmation email from Haneco, with a unique case number and should only respond to this original email to ensure your case is resolved in a timely manner. If all documentation is sent and complete you will be provided with a credit number or instructions for the next step.