Advertisement
AC Charge | 100-115V, 600W Max |
Solar Charge | 12-45V, 25A 600W Max |
USB-C Charge | 20V/5A,100W Max |
AC (x2) | 50/60 Hz Pure Sine Wave, 600W Max |
USB-A (x2) | 5V/2.4A, 12W |
USB-A QC3.0 (x1) | 5V/3A, 15W; 9V/2A, 18W |
USB-C | 5/9/12/15/20V, 5A 100W Max |
Wireless Charge | 5V/3A, 15W Max |
Operating Temperature | 32°F to 105°F |
Discharge Temperature | 14°F to 113°F |
Charge Temperature | 32°F to 113°F |
Storage Temperature | 32°F to 100°F |
Cell Chemistry | Li(NiCoMn)02 |
Cycle Life | 700+ Cycles to 80% Capacity |
Net Weight | 6.6kg/14.6LBS |
Product Dimensions | 27*18*19inches |
Capacity | 286WH |
Certification | FCC, PSE, ROHS, UN38.3 |
The fastest power station source in the universe. AC/PV 600W Max Input, 0.5H Full Charge 0%-90%
AC frequency automatic identification, no need to manually switch, protect your appliance.
The infinitely variable speed fan, intelligent y adjusts the speed according to the temperature and output power, keeping you away from the noise of the fan.
Smart LED screen, what you see is real, let you know any condition of the FLASH-300.
Reduce standby and running power, and the usage time increased by 10%-15% compared with the same capacity power stations.
10 Error Codes + Triple Protection System to avoid potential safety hazards to the greatest extent.
![]() | Long press 25 to turn on/off the FLASH -300, short press to wake up / turn off the screen. (After turning on the power, the other four buttons can be turned on normally.) |
![]() | Short press 1~6 times (Wake up screen+ambient light full bright/ half brig ht/ flashlight full bright/ha If bright/ SOS mode/ all lights off.) Press 2s to turn off the LED light in any mode. |
![]() | Press 1s to turn on/off the AC port. |
![]() | Press 1s to turn on/off the USB - TypeC - Wireless port. ( |
![]() | Press 1s to turn on/off the DC port. |
![]() | How to switch frequency?
|
Whether your are charging or discharging, the screen will tu rn off automatically after 30s. Short press any five buttons can wake up the display screen
Turn off automatically after 5 minutes while there is no input or output.
USB port turns off automatically wh ile the output is lower than 3W for one hour. DC & AC port turn off automatically while the output is lower then 5W for one hour.
All abnormal states are accompanied by error codes or buzzer warnings. FLASH-300 can resume work after the abnormarty is cancelled automatically.
1 | ![]() | It lights up when FLASH-300 is recharging from solar panel. |
2 | ![]() | It lights up when FLASH-300 is recharging from wall outlets. |
3 | ![]() | It lights up when FLASH-300 is charging other devices from car charging port. |
4 | ![]() | It shows the current electricity frequency of the unit. |
5 | ![]() | It lights up when the inverter over 80oC/176oF. |
6 | ![]() | It lights up the ambient temperature is below 0oC / 32oF when charging & below -20oC / -4oF when discharging. |
7 | ![]() | It lights up when the electronic devices overall are drawing over 605W Watt. |
8 | ![]() | It will display 10 codes under different abnormal states. |
BougeRV's fast-charge technology is specifically for AC charging, offering 600W of max input power. In case of unusual situations (ex. thunderstorm weather) where the AC input current remains higher than 15A, the charging input port will initiate the self-protection function and the overload protection switch will automatically. After confirming the charging environment is safe and the product is normal, you can press the overload protection switch to resume recharging.
You can recharge the product through the Car Charging Input Port. It supports 13.5V car chargers and 10A Max charging current. To avoid failure to start due to insufficient car battery, please confirm that the vehicle has been started before using the car charger. BougeRV takes no responsibility for any loss or damages caused by failing to follow instructions.
The panel can be wired in series to produce the expected voltage output.
The solar panel can be wired in parallel to produce the expected current output with the solar parallel connector.
Using four 200w panels to connect in series and then in parallel, FLASH-300 support 600W Max Input, 0-90% for half an hour.
The output of solar panels is affected by light and the angle of position, so there will be a loss of about 20%, if you want to achieve the maximum input of 600W, we recommend you combine with 800W solar panels.
AC Charging: Around 0-5H, 0-90%
Solar Charging: Around 0-5H, 0-90%
Car Charging: Around 2,4H, 0-90%
USB-C Charging: Around 3H, 0-90%
Phone (3200mAh): About 20 Charges
Camera (15Wh): About 16 Charges
Tablet (28.6Wh): About 9 Charges
Laptop (50Wh): About 5 Charges
Radio (10W): About 20 Hours
Game console (15W): About 15 Hours
Drone (30Wh): About 9 Charges
Car Fridge (50W): About 7 Hours
Fan (10W): About 20 Hours
LED Lights (20W): About 12 Hours
Electric Blanket (40W): About 6 Hours
TV (140W): About 2 Hours
Module | Error Code | Explanation | Troubleshooting |
INVERTER | E01: Overload Protection | The output power over 605W for minute, inverter turns off, overload character flashes, buzzer alarms; output power over 720W for 30 seconds, inverter turns off; output power over 900W for 1 seconds, inverter turns off | When the code appears, please cut off the appliance in time, the error will disappear immediately, please insert the appliance which rated power less than 600W. |
E02: Over-Temperature Protection | Cut off the output when the temperature is above 176oF, and autornatically recovers when the temperature is below 140oF | Please discharge it under the suitable temperature environment (14oF to 113oF) | |
E03: Over / Under-Voltage Protection | When voltage of the inverter is over 140 or below 90V, it will turn off | Step 1:Turn on the power station again and observe whether the error code is cancelled. Step 2: If the code still exists, please contact our customer service | |
E04: Short Circuit Protection | FLASH-300 detects that there is a short circuit in the electrical appliance | Step 1: Cut aff the output immediately. Step 2: Turn on the power station again and observe whether the error code is cancelled. Step 3: If the code still exists, please contact our customer service. | |
E05: AC / Under-Voltage Protection | When the voltage of AC is below 85V, the current of the AC input will drop from 25A to 10A. | Please use the AC charging cable and compliant outlet provided by us for charging, and do not modify the charging cable and outlet without the guidance of a professional electrician. | |
PV | P01: Over / Under-Voltage Protection | When the PV input voltage is over 45V or less than 11V, turns off the PV input | Please check whether the voltage is too high due to too many panels connected in series. If you use a single panel to charge, please make sure the voltage is over 11V. |
P02: Overcurrent Protection | When the PV input current is over 35A, it will turn off the PV input | Please check whether the parallel connection of multiple panels leads to excessive current. It is recommended to increase the series connection and reduce the parallel connection. | |
P20: Overheating Protection | When the temperature of the PV module is over 158°F, it will turn off the PV input | Step 1: Stop charging and observe whether the error code disappears after the temperature drops Step 2: If the code still exists, please contact our customer service | |
AC | C02: Overcurrent Protection | When the AC charging input current is over 26A, turn off the input | The fuse will pop up automatically. If you want to continue charging, please press the fuse button. |
C08: Overheating Protection | Cut off the input when the temperature is above 167°F, and automatically recover when the temperature is below 131°F. | Please charge it under the suitable temperature environment (32°F to 113°F) |
Check the package and make sure you receive all accessories. If any of these is missing, please feel free to contact us via service@bougerv.com
Q1: Can the FLASH-300 be charged while using?
A: Yes, the FLASH-300 allows pass-through charging BUT we don't recommend you to do that which will bring damage to the battery.
Tips: using appliances under 100% full battery, appliances will only use the AC and the capacity of the power station will not decrease.
Q2: Why is the remaining usage time on the display inconsistent with the actual use?
A: Because the power of the appliance is in a dynamic fluctuation range, the software algorithm is calculated based on the real-time power, the actual use time will have a certain deviation from the display screen, this is a normal phenomenon.
Q3: What should I do if I want to use the car cigarette port to charge the FLASH-300?
A: You can use the cigarette to Anderson adaptor we provide, and then insert the Anderson into the FLASH-300, around 135W Max.
Q4: What kind of solar panel should I buy to charge the FLASH-300?
A: We recommend you to buy the BougeRV Portable Solar Panel to charge FLASH-300. If you want to know more specifications, you can search on Amazon using keywords: BougeRV Solar Panels.
Q5: Where can I find any video about the operation and use of FLASH-300?
A: Search BougeRV on YOUTUBE, enter our official channel, end search for FLASH-300
Q6: What matters should I pay attention to in daily use?
A:
Product Use:
Product Charging:
Product Storage:
Product Maintenance:
Travel Notice:
Do Not bring this product on flights.
service@bougerv.com
1-669-232-7427 I Sun-Thu 6PM-12AM(PST)
www.bougerv.com
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Advertisement
Need help?
Do you have a question about the FLASH-300 and is the answer not in the manual?
Questions and answers