El.Mo LUPUSC2K Technical Manual

Compact radio transmitters for wireless ng-trx intrusion detection systems

Advertisement

Quick Links

LUPUSC2K - VOLANSC2K
AND BROWN VERSIONS
Compact radio transmitters for
wireless NG-TRX intrusion detection
systems
090011113
IT08020000001624

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LUPUSC2K and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for El.Mo LUPUSC2K

  • Page 1 LUPUSC2K - VOLANSC2K AND BROWN VERSIONS Compact radio transmitters for wireless NG-TRX intrusion detection systems 090011113 IT08020000001624...
  • Page 2 (explosion and fire). EU DECLARATION OF CONFORMITY Hereby, EL.MO. S.p.A. declares that the radio equipment LUPUSC2K - VOLANSC2K is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following Internet address: elmospa.com –...
  • Page 3: Generals

    Their general features can be summarized as follows: • LUPUSC2K can transmit the state variations of magnetic contacts and of the roll-up shutter sensor wired to its terminals. LUPUSC2K is identified by the control unit as a multi-channel device; it occupies up to 3 zones for the transmission of the anomaly/alarm states of the REED magnetic contact (located on housing side), the magnetic contact wired to the terminal board and the roll-up shutter detector connected to the proper terminal.
  • Page 4 1 if supervision time is set as lower than 60 min; grade 2 if supervision time is set as lower than 20 min LUPUSC2K and VOLANSC2K are accessories for VIDOMO2K and VICOMPATC2K control units (belonging to the Villeggio NG-TRX system) and other expressly compatible systems.
  • Page 5: Mechanical Features

    090011113 - TECHNICAL MANUAL - LUPUSC2K - VOLANSC2K 3. MECHANICAL FEATURES View of the transmitter plastic housing and of the external magnet. DIMENSIONS IN mm THE DIMENSIONS OF THE MAGNET MIGHT VARY REMOVABLE MAGNET - SENSOR SCREW COVER CAPS FIXING DISTANCE 4 mm MAX 4.
  • Page 6: How To Distinguish The Devices

    LUPUSC2K - VOLANSC2K - TECHNICAL MANUAL - 090011113 5. HOW TO DISTINGUISH THE DEVICES The following picture shows the differences between the two transmitters. IDENTIFICATION LABEL MOD. LUPUSC2K STUCK ON PLASTIC HOUSING SIDE BLUE LED FOR VISUALIZATION NO TRIMMER OF OPERATION AND TRANSMISSION...
  • Page 7: Installation

    090011113 - TECHNICAL MANUAL - LUPUSC2K - VOLANSC2K 6. INSTALLATION The installer shall verify that no electrostatic charges are present upon housing opening; internal electronic boards and accessory components may be damaged by such charges. The same care shall be used during installation, updates and maintenance procedures.
  • Page 8: Coverage And Sensitivity

    LUPUSC2K - VOLANSC2K - TECHNICAL MANUAL - 090011113 Objects that can modify and/or reduce the range (example with Villeggio NG-TRX control unit): THE CONTROL UNIT CAN ALSO MANAGE ACCESSORY DEVICES BELONGING TO STANDARD VILLEGGIO AND HELIOS SERIES METAL GRIDS AND...
  • Page 9: Mounting

    After these operations, proceed with wirings, powering, software configuration. Close the housing making sure to fit the closing spring belonging to the Tamper protection microswitch properly in place. Finally, move ahead with testing. Example of LUPUSC2K transmitter mounting inside the housing of a roll-up shutter.
  • Page 10: Protection Against Removal From Mounting Surface

    LUPUSC2K - VOLANSC2K - TECHNICAL MANUAL - 090011113 8.2 Protection against removal from mounting surface Compliance with EN 50131 regulation grade 2 requires that the device is protected against removal from the mounting surface. Install KSAS1013 kit (green) before fixing the detector base to the fixture.
  • Page 11: Electrical Connections

    090011113 - TECHNICAL MANUAL - LUPUSC2K - VOLANSC2K 9. ELECTRICAL CONNECTIONS 9.1 Board general view IMPACT SENSITIVITY TUNING ONLY FOR VOLANSC2K MOD. (THE PIEZO SENSOR IS LOCATED EVENT DETECTION INDICATOR ON BOARD BOTTOM) SMD VIAL WITH MAGNETIC THE PRODUCT IS PROVIDED WITH THE CONTACT, NEXT TO THE BATTERY AS STANDARD EQUIPMENT.
  • Page 12: Allowed Wiring Types For Lupusc2K Model

    LUPUSC2K - VOLANSC2K - TECHNICAL MANUAL - 090011113 9.3 Allowed wiring types for LUPUSC2K model Using the software application, you can fully configure wiring types in order to optimize the device operations for the required functions. The following screen is displayed in the “Zones” page, “Radio devices NG-TRX” tab corresponding to the selected zone.
  • Page 13: Volansc2K General Connections

    090011113 - TECHNICAL MANUAL - LUPUSC2K - VOLANSC2K 9.4 VOLANSC2K general connections PIEZO SENSOR POSITION. See Channel 2 software settings THE PIEZO SENSOR IS LOCATED IN THIS POSITION WARNING: ON THE BOARD BOTTOM TO GET THE HIGHEST SENSITIVITY, SET THE...
  • Page 14: Code Memorization

    After configuring the settings, write the configuration in the control unit and then perform the functional test. 10. CODE MEMORIZATION Note: during the code acquisition phases, keep in mind that the control unit identifies LUPUSC2K and VOLANSC2K as multi-channel devices.
  • Page 15: Transmitter Configuration Via Software

    090011113 - TECHNICAL MANUAL - LUPUSC2K - VOLANSC2K 11. TRANSMITTER CONFIGURATION VIA SOFTWARE The transmitter can be fully programmed by using BrowserOne v. 3.4.7 or higher with control unit module v. 8.4.11 or higher. The control unit firmware must be 8.2.0.0 or higher.
  • Page 16 Open the “System options” page, “Options NG-TRX” tab, where the general options of the NG-TRX devices are available. Here you can select the settings that also involve the LUPUSC2K and VOLANSC2K transmitters. Selection of the multi-channel reception (3 channels), also involving the default/preferential channel selection and the transmission strategy.
  • Page 17: Operating Modes

    090011113 - TECHNICAL MANUAL - LUPUSC2K - VOLANSC2K 12. OPERATING MODES 12.1 Walk test - System test The Walk test condition can be activated via keypad, from the SYSTEM TEST » ZONE TEST menu. The beginning of the operating mode is indicated by three beeps of the internal buzzer and by the LED blinking.
  • Page 18: Battery Replacement And Disposal

    13. BATTERY REPLACEMENT AND DISPOSAL The LUPUSC2K and VOLANSC2K detectors use a Lithium 3.6 V 1.2 Ah battery mod. ER14250 or LS1425 (1/2AA). Replace this battery only with a new one of the same model. Observe the following insertion instructions: 1.
  • Page 19: Table Of Contents

    9.3 Allowed wiring types for LUPUSC2K model ........
  • Page 20 LUPUSC2K - VOLANSC2K - Compact radio transmitters for wireless NG-TRX intrusion detection systems TECHNICAL MANUAL - August 2018 edition 090011113 The information and product features herein are not binding and may be changed without prior notice. EL.MO. SpA Via Pontarola, 70 - 35011 Campodarsego (PD) - Italy...

This manual is also suitable for:

Volansc2k

Table of Contents