Do you have a question about the V098 and is the answer not in the manual?
Questions and answers
Summary of Contents for Frank van Dijk Trading V098
Page 1
INSTRUCTION MANUAL display cooler SC98/V097 DISPLAY COOLER V098 EN 55014-1:2017. EN 55014-2:2015 EN 61000-3-2:2014, EN 61000-3-3:2013 Please read this manual carefully, and make sure to keep this manual in the place accessible by the user at any time 30-05-2022...
Page 2
Lamp is not on Replace the lamp Caution: Dismantling the unit by non-professional Glass Door staff is prohibited, it will cause hazard. Brace Foot 2、 Specifications V098 Model Climatic class Storage Temperature ( ℃) 0~10 Ⅰ Anti-shock protection class Capacity (L)
Page 3
3. Safety Cautions Problems Possible cause Ways to solve problems 1) This unit uses AC220V/50Hz power, there should be a 500va stabilizer if the voltage fluctuation exceed AC198V~242V Disconnect the power supply 2) The user should hold the plug when the power is on/off, dragging or immediately and reconnect pulling the power cord is prohibited.
Page 4
4) After moving the unit, place the unit for 30 minutes before switching it on. 8. Maintenance Running: close the door and connect the power, turn on the lamp switch on the Disconnect the power supply before maintenance for the machine! control panel, the lamp is on.
Need help?
Do you have a question about the V098 and is the answer not in the manual?
Questions and answers